The following report was received from theThe following report was received from the Commonwealth of Kentucky via fax:</br>KY RHB (Kentucky Radiation Health Branch) was notified by telephone on 2/12/2019 at 1315 EST by a representative from a specifically licensed facility, North American Stainless, that on Sunday, 2/10/2019, North American Stainless encountered a 'breakout' when molten steel escaped and poured onto billet caster molds located below a 'tundish' filled with molten steel. One of the molds attached to a Berthold Model No. LB300ML Mold Level Control fixed gauging device, serial number 9415, containing 1 mCi (37 MBq) Co-60 (source serial number 1819-11-15) was covered with the liquid steel encapsulating the source holder. After the steel and mold had cooled, it was freed on 2/12/2019 and segregated. The encapsulating steel rendered the device on-off mechanism (shutter) inoperable. Initial readings taken with a Ludlum 2241-3 survey instrument measured 6.25 mR/hr measured 12 inches directly in front of the window, and 1.25 mR/hr measured 90 degrees from the line of the window measured at a distance of 12 inches. Readings at the back of the source holder were 132 microR/hr measured at a distance of 12 inches. No overexposures have been reported. On 2/12/2019, Radiametric Technologies, a service provider located in Lorain, Ohio, requested reciprocal approval and was granted reciprocity on 2/13/2019 in order to assess and remediate the situation. </br>The fixed gauging device involved in the incident was recently leak tested (test conducted on 7/31/2018) by Suntrac Services, League City TX. Radiametric Technologies, Lorain OH, recently tested the source holder on-off mechanism (1/31/2019) and it was found to be in good working order. North American Stainless is reviewing the incident to avoid future incidents involving 'tundish' failures. A full report will be provided once the remediation is complete. </br>Reporting criteria in 10 CFR 30.50(b)(2).</br>KY Report #KY190001in 10 CFR 30.50(b)(2). KY Report #KY190001  +
05:00:00, 10 February 2019  +
53,871  +
12:00:00, 13 February 2019  +
05:00:00, 10 February 2019  +
The following report was received from theThe following report was received from the Commonwealth of Kentucky via fax:</br>KY RHB (Kentucky Radiation Health Branch) was notified by telephone on 2/12/2019 at 1315 EST by a representative from a specifically licensed facility, North American Stainless, that on Sunday, 2/10/2019, North American Stainless encountered a 'breakout' when molten steel escaped and poured onto billet caster molds located below a 'tundish' filled with molten steel. One of the molds attached to a Berthold Model No. LB300ML Mold Level Control fixed gauging device, serial number 9415, containing 1 mCi (37 MBq) Co-60 (source serial number 1819-11-15) was covered with the liquid steel encapsulating the source holder. After the steel and mold had cooled, it was freed on 2/12/2019 and segregated. The encapsulating steel rendered the device on-off mechanism (shutter) inoperable. Initial readings taken with a Ludlum 2241-3 survey instrument measured 6.25 mR/hr measured 12 inches directly in front of the window, and 1.25 mR/hr measured 90 degrees from the line of the window measured at a distance of 12 inches. Readings at the back of the source holder were 132 microR/hr measured at a distance of 12 inches. No overexposures have been reported. On 2/12/2019, Radiametric Technologies, a service provider located in Lorain, Ohio, requested reciprocal approval and was granted reciprocity on 2/13/2019 in order to assess and remediate the situation. </br>The fixed gauging device involved in the incident was recently leak tested (test conducted on 7/31/2018) by Suntrac Services, League City TX. Radiametric Technologies, Lorain OH, recently tested the source holder on-off mechanism (1/31/2019) and it was found to be in good working order. North American Stainless is reviewing the incident to avoid future incidents involving 'tundish' failures. A full report will be provided once the remediation is complete. </br>Reporting criteria in 10 CFR 30.50(b)(2).</br>KY Report #KY190001in 10 CFR 30.50(b)(2). KY Report #KY190001  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 13 February 2019  +
201-499-57  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
12:30:05, 22 February 2019  +
12:00:00, 13 February 2019  +
3.292 d (79 hours, 0.47 weeks, 0.108 months)  +
05:00:00, 10 February 2019  +
Kentucky +  and Ohio +
Agreement State Report - Gauge Device Damaged by Molten Steel  +