The following notification is an excerpt fThe following notification is an excerpt from the received report:</br>On November 30, 2017, an internal wire in a 480VAC cubicle, breaker B3424, was discovered to be terminated using incorrect size wire lugs. This deviation was identified by Monticello Nuclear Generating Plant (MNGP) electrical maintenance staff during bench testing of the cubicles in preparation for implementation of a modification.</br>The cubicles were received by MNGP in September, 2017 from Westinghouse Electric Co.</br>On January 26, 2017, MNGP completed an evaluation of this deviation and concluded this condition represents a significant safety hazard. As a result, this condition is a defect and is reportable pursuant to 10 CFR 21.21 (d)(4).</br>Basic Component: Westinghouse: Eaton Breaker Cubicle Part No. 10149D92G05</br>On November 30, 2017, an internal wire in a 480VAC cubicle, breaker 83424, was discovered to be terminated using incorrect size wire lugs. This condition was discovered during bench testing in preparation for implementing a modification to the Control Room Ventilation (CRV) system. The wire connection was found loose and was able to be lifted off of the terminal without removing the screw. Upon further examination, the internal diameter of ring termination lugs was found to be too large, providing only a partial surface area for screw head contact.</br>The affected lugs were on contactor coil resistor terminations internal to the cubicle. Without sufficient contact area or connection to the wiring on the resistor, control power could be lost to the contactor coil resulting in the fan V-EF-40A not starting, which would prevent proper ventilation to the room housing safety related batteries required to be operable during an accident scenario. Therefore, MNGP determined that a substantial safety hazard could have been created had the breaker cubicle been installed with the defect uncorrected.</br>This defect was evaluated according to the station's Part 21 reporting process. The evaluation was completed on January 26, 2018 and the reporting officer was informed on January 30, 2018.</br>Westinghouse was notified of this condition and the condition was incorporated into their corrective action program, number 100506324. The Westinghouse contact person is Adam Tokar, 724-722-6042. No further information on the vendor's corrective actions is known.</br>MNGP entered the condition into the MNGP Corrective Action Program under 501000005918. Monticello has corrected the lugs on the installed breaker, B4423. The remaining uninstalled cubicles purchased by Monticello are being corrected in accordance with MNGP procedure MWl-8-M-4.06, Conductor Termination, prior in installation in the plant.ation, prior in installation in the plant.  
06:00:00, 26 January 2018  +
53,193  +
16:23:00, 1 February 2018  +
06:00:00, 26 January 2018  +
The following notification is an excerpt fThe following notification is an excerpt from the received report:</br>On November 30, 2017, an internal wire in a 480VAC cubicle, breaker B3424, was discovered to be terminated using incorrect size wire lugs. This deviation was identified by Monticello Nuclear Generating Plant (MNGP) electrical maintenance staff during bench testing of the cubicles in preparation for implementation of a modification.</br>The cubicles were received by MNGP in September, 2017 from Westinghouse Electric Co.</br>On January 26, 2017, MNGP completed an evaluation of this deviation and concluded this condition represents a significant safety hazard. As a result, this condition is a defect and is reportable pursuant to 10 CFR 21.21 (d)(4).</br>Basic Component: Westinghouse: Eaton Breaker Cubicle Part No. 10149D92G05</br>On November 30, 2017, an internal wire in a 480VAC cubicle, breaker 83424, was discovered to be terminated using incorrect size wire lugs. This condition was discovered during bench testing in preparation for implementing a modification to the Control Room Ventilation (CRV) system. The wire connection was found loose and was able to be lifted off of the terminal without removing the screw. Upon further examination, the internal diameter of ring termination lugs was found to be too large, providing only a partial surface area for screw head contact.</br>The affected lugs were on contactor coil resistor terminations internal to the cubicle. Without sufficient contact area or connection to the wiring on the resistor, control power could be lost to the contactor coil resulting in the fan V-EF-40A not starting, which would prevent proper ventilation to the room housing safety related batteries required to be operable during an accident scenario. Therefore, MNGP determined that a substantial safety hazard could have been created had the breaker cubicle been installed with the defect uncorrected.</br>This defect was evaluated according to the station's Part 21 reporting process. The evaluation was completed on January 26, 2018 and the reporting officer was informed on January 30, 2018.</br>Westinghouse was notified of this condition and the condition was incorporated into their corrective action program, number 100506324. The Westinghouse contact person is Adam Tokar, 724-722-6042. No further information on the vendor's corrective actions is known.</br>MNGP entered the condition into the MNGP Corrective Action Program under 501000005918. Monticello has corrected the lugs on the installed breaker, B4423. The remaining uninstalled cubicles purchased by Monticello are being corrected in accordance with MNGP procedure MWl-8-M-4.06, Conductor Termination, prior in installation in the plant.ation, prior in installation in the plant.  
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 1 February 2018  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
01:41:05, 2 March 2018  +
16:23:00, 1 February 2018  +
6.433 d (154.38 hours, 0.919 weeks, 0.211 months)  +
06:00:00, 26 January 2018  +
Part-21 Notification - Improper Lugs in a Breaker Cubicle  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.