TopWorx Information Notice: TIN 2016-01
13 … TopWorx Information Notice: TIN 2016-01</br>13 June 2016</br>Subject: C7 Switches</br>Equipment Affected By This Information Notice: (4) C7-14521-E25 shipped on 6 August 2014</br>Purpose: The purpose on this TopWorx Information Notice (TIN) is to alert Fisher that, as of 27 May 2016, TopWorx was made aware of a situation which may affect the performance of the aforementioned equipment. TopWorx is informing Fisher of this circumstance in accordance with Section 21.21 (b) and 50.55 (e) of 10 CFR 21.</br>Applicability: This notice applies only to (4) TopWorx C7-14521-E25 shipped on 6 August 2014 to Fisher on Fisher Purchase Order 4123318082.</br>Discussion: Fisher Purchase Order 4123318082 specified that TopWorx SV7-14521-E25 were to be provided. Although the C7 switches provided to Fisher in error are also Nuclear-qualified switches, they do not have the same qualification pedigree and therefore cannot be considered qualified for HELB (High Energy Line Break) applications (zones 5 and 10). TopWorx has no indication that the switches provided are defective, yet TopWorx is unable to determine the application or status of use and therefore submits this notice.</br>Extent of Condition: Fisher Purchase Orders were reviewed and no other order was found where an incorrect switch was provided.</br>Actions Required: If the units mentioned above are to be installed in a zone for which the C7 switch is not qualified, then the units must be replaced. In addition, TopWorx has initiated a Non Conformance Report (NCR 05192016-01) to prevent reoccurrence of this issue.</br>10 CFR 21 Implications: TopWorx requests that the recipient of this notice review it and take appropriate action in accordance with 10 CFR 21.</br>If there are any technical questions or concerns, please contact:</br>John Conrad</br>Manger, Quality</br>TopWorx</br>3300 Fern Valley Road</br>Louisville, KY 40213</br>Fax: (502) 969-8000</br>Phone: (502) 873-4661</br>John.conrad@emerson.comne: (502) 873-4661
John.conrad@emerson.com +
05:00:00, 6 August 2014 +
52,003 +
14:03:00, 13 June 2016 +
05:00:00, 6 August 2014 +
TopWorx Information Notice: TIN 2016-01
13 … TopWorx Information Notice: TIN 2016-01</br>13 June 2016</br>Subject: C7 Switches</br>Equipment Affected By This Information Notice: (4) C7-14521-E25 shipped on 6 August 2014</br>Purpose: The purpose on this TopWorx Information Notice (TIN) is to alert Fisher that, as of 27 May 2016, TopWorx was made aware of a situation which may affect the performance of the aforementioned equipment. TopWorx is informing Fisher of this circumstance in accordance with Section 21.21 (b) and 50.55 (e) of 10 CFR 21.</br>Applicability: This notice applies only to (4) TopWorx C7-14521-E25 shipped on 6 August 2014 to Fisher on Fisher Purchase Order 4123318082.</br>Discussion: Fisher Purchase Order 4123318082 specified that TopWorx SV7-14521-E25 were to be provided. Although the C7 switches provided to Fisher in error are also Nuclear-qualified switches, they do not have the same qualification pedigree and therefore cannot be considered qualified for HELB (High Energy Line Break) applications (zones 5 and 10). TopWorx has no indication that the switches provided are defective, yet TopWorx is unable to determine the application or status of use and therefore submits this notice.</br>Extent of Condition: Fisher Purchase Orders were reviewed and no other order was found where an incorrect switch was provided.</br>Actions Required: If the units mentioned above are to be installed in a zone for which the C7 switch is not qualified, then the units must be replaced. In addition, TopWorx has initiated a Non Conformance Report (NCR 05192016-01) to prevent reoccurrence of this issue.</br>10 CFR 21 Implications: TopWorx requests that the recipient of this notice review it and take appropriate action in accordance with 10 CFR 21.</br>If there are any technical questions or concerns, please contact:</br>John Conrad</br>Manger, Quality</br>TopWorx</br>3300 Fern Valley Road</br>Louisville, KY 40213</br>Fax: (502) 969-8000</br>Phone: (502) 873-4661</br>John.conrad@emerson.comne: (502) 873-4661
John.conrad@emerson.com +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 13 June 2016 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
22:16:30, 24 September 2017 +
14:03:00, 13 June 2016 +
677.377 d (16,257.05 hours, 96.768 weeks, 22.269 months) +
05:00:00, 6 August 2014 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.