The following information was provided by … The following information was provided by the State of Texas via email:</br>On February 12, 2016, the Agency (Texas Department of State Health Services) was notified by the licensee's radiation safety officer (RSO) that on February 11, 2016, while performing a routine inspection of a Berthold model LB 300 l nuclear gauge, they found the source shutter was stuck in the open position. Open is the normal position for the gauge shutter. The gauge contains a one millicurie (original activity, current activity 0.07 mCi.) Cobalt-60 source. The RSO stated the dose rates at and around the gauge are normal. He (the RSO) stated no individuals, including members of the general public, will be exposed to any additional radiation due to the failure. The RSO stated the manufacturer has been contacted and will be at the licensee's facility the week of February 15, 2016 to fix or replace the gauge. Additional information will be provided as it is received in accordance with SA-300.</br>Texas Incident #: I-9378nce with SA-300.
Texas Incident #: I-9378 +
06:00:00, 11 February 2016 +
51,731 +
13:07:00, 12 February 2016 +
06:00:00, 11 February 2016 +
The following information was provided by … The following information was provided by the State of Texas via email:</br>On February 12, 2016, the Agency (Texas Department of State Health Services) was notified by the licensee's radiation safety officer (RSO) that on February 11, 2016, while performing a routine inspection of a Berthold model LB 300 l nuclear gauge, they found the source shutter was stuck in the open position. Open is the normal position for the gauge shutter. The gauge contains a one millicurie (original activity, current activity 0.07 mCi.) Cobalt-60 source. The RSO stated the dose rates at and around the gauge are normal. He (the RSO) stated no individuals, including members of the general public, will be exposed to any additional radiation due to the failure. The RSO stated the manufacturer has been contacted and will be at the licensee's facility the week of February 15, 2016 to fix or replace the gauge. Additional information will be provided as it is received in accordance with SA-300.</br>Texas Incident #: I-9378nce with SA-300.
Texas Incident #: I-9378 +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 12 February 2016 +
01577 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
01:45:41, 2 March 2018 +
13:07:00, 12 February 2016 +
1.297 d (31.12 hours, 0.185 weeks, 0.0426 months) +
06:00:00, 11 February 2016 +