During Main Steam Safety Valve testing con … During Main Steam Safety Valve testing conducted prior to refueling outages, normally closed watertight doors are opened in support of the testing. If a postulated one square foot non-mechanistic crack were to occur within the Break Exclusion Area during the test, safety related equipment located just outside of these doors could be adversely affected. With these watertight doors open, compliance with the Comanche Peak licensing basis may not be assured. </br>This condition has been conservatively determined to be reportable as an unanalyzed condition per 10 CFR 50.72(b)(3)(ii)(B). Currently, the watertight doors on both Units 1 and 2 are closed, therefore, all safety related equipment is currently operable. Comanche Peak Engineering is performing a review of the original Comanche Peak licensing basis regarding the non-mechanistic crack event to determine what equipment impacts are required to be assessed.</br>The NRC Resident Inspector has been notified. NRC Resident Inspector has been notified. +
22:00:00, 19 February 2015 +
50,835 +
20:18:00, 19 February 2015 +
22:00:00, 19 February 2015 +
During Main Steam Safety Valve testing con … During Main Steam Safety Valve testing conducted prior to refueling outages, normally closed watertight doors are opened in support of the testing. If a postulated one square foot non-mechanistic crack were to occur within the Break Exclusion Area during the test, safety related equipment located just outside of these doors could be adversely affected. With these watertight doors open, compliance with the Comanche Peak licensing basis may not be assured. </br>This condition has been conservatively determined to be reportable as an unanalyzed condition per 10 CFR 50.72(b)(3)(ii)(B). Currently, the watertight doors on both Units 1 and 2 are closed, therefore, all safety related equipment is currently operable. Comanche Peak Engineering is performing a review of the original Comanche Peak licensing basis regarding the non-mechanistic crack event to determine what equipment impacts are required to be assessed.</br>The NRC Resident Inspector has been notified. NRC Resident Inspector has been notified. +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
100 +
00:00:00, 19 February 2015 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
22:18:22, 24 September 2017 +
20:18:00, 19 February 2015 +
true +
false +
-0.0708 d (-1.7 hours, -0.0101 weeks, -0.00233 months) +
22:00:00, 19 February 2015 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.