Browse wiki
Jump to navigation
Jump to search
100 +
At 1003 EST, Unit 1 declared an Unusual Ev … At 1003 EST, Unit 1 declared an Unusual Event - EAL HU 3.1 (Toxic/corrosive/asphyxiate/flammable gas release that could affect normal operations) due to smoke in the Unit 1 "B" Battery room. The Unit 1 standby UPS inverter cabinet was smoking and leaking fluid. The fire brigade responded and declared the room uninhabitable due to smoke. The standby inverter was de-eneergized and the smoke subsided. The standby inverter was not in service and no plant equipment was lost. Unit 2 was not affected. Request for offsite assistance was sent to the local fire department but was not needed.</br> </br>The licensee notified the NRC Resident Inspector, the State of North Carolina, and local emergency response organizations.</br>Notified Federal Agencies (DHS SWO, FEMA Operations Center, NICC Watch Officer, and NuclearSSA) via email.</br>* * *UPDATE PROVIDED TO JEFF ROTTON FROM MARTIN HAMM AT 1045 EST ON 02/03/2014* * *</br>Licensee terminated from the Unusual Event at 10:25 EST.</br>Licensee notified the NRC Resident Inspector, the State of North Carolina and local emergency response organizations.</br>Notified Federal Agencies (DHS SWO, FEMA Operations Center, NICC Watch Officer and Nuclear SSA) via email. Watch Officer and Nuclear SSA) via email. +
15:03:00, 3 February 2014 +
49,788 +
10:26:00, 3 February 2014 +
15:03:00, 3 February 2014 +
At 1003 EST, Unit 1 declared an Unusual Ev … At 1003 EST, Unit 1 declared an Unusual Event - EAL HU 3.1 (Toxic/corrosive/asphyxiate/flammable gas release that could affect normal operations) due to smoke in the Unit 1 "B" Battery room. The Unit 1 standby UPS inverter cabinet was smoking and leaking fluid. The fire brigade responded and declared the room uninhabitable due to smoke. The standby inverter was de-eneergized and the smoke subsided. The standby inverter was not in service and no plant equipment was lost. Unit 2 was not affected. Request for offsite assistance was sent to the local fire department but was not needed.</br> </br>The licensee notified the NRC Resident Inspector, the State of North Carolina, and local emergency response organizations.</br>Notified Federal Agencies (DHS SWO, FEMA Operations Center, NICC Watch Officer, and NuclearSSA) via email.</br>* * *UPDATE PROVIDED TO JEFF ROTTON FROM MARTIN HAMM AT 1045 EST ON 02/03/2014* * *</br>Licensee terminated from the Unusual Event at 10:25 EST.</br>Licensee notified the NRC Resident Inspector, the State of North Carolina and local emergency response organizations.</br>Notified Federal Agencies (DHS SWO, FEMA Operations Center, NICC Watch Officer and Nuclear SSA) via email. Watch Officer and Nuclear SSA) via email. +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
100 +
00:00:00, 3 February 2014 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
01:51:50, 2 March 2018 +
10:26:00, 3 February 2014 +
true +
false +
-0.193 d (-4.62 hours, -0.0275 weeks, -0.00633 months) +
15:03:00, 3 February 2014 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.