A review of industry operating experience … A review of industry operating experience regarding the impact of unfused Direct Current (DC) ammeter circuits has determined the described condition is applicable to the Salem Nuclear Power Plant resulting in an unanalyzed condition with respect to 10 CFR 50 Appendix R. The original plant wiring design and associated analysis for ammeters associated with the station batteries are not provided with overcurrent protection features to limit the fault current.</br>A postulated fire that results in a short to ground concurrent with an opposite polarity short from the same battery could result in excessive current flow (i.e., heating) in the ammeter wiring. This excessive current could result in a secondary fire in another fire area. The secondary fire could adversely affect safe shutdown equipment and cause loss of the ability to conduct a safe shutdown as required by 10 CFR 50 Appendix R. The areas affected are the Control Room, Relay Rooms and 460 Volt Switchgear Rooms.</br>This condition is being reported in accordance with 10 CFR 50.72(b)(3)(ii)(B). Interim compensatory measures (i.e., fire watches) have been implemented for the affected areas of the plant.</br>The licensee has notified the NRC Resident Inspector.e has notified the NRC Resident Inspector. +
18:22:00, 14 November 2013 +
49,539 +
16:08:00, 14 November 2013 +
18:22:00, 14 November 2013 +
A review of industry operating experience … A review of industry operating experience regarding the impact of unfused Direct Current (DC) ammeter circuits has determined the described condition is applicable to the Salem Nuclear Power Plant resulting in an unanalyzed condition with respect to 10 CFR 50 Appendix R. The original plant wiring design and associated analysis for ammeters associated with the station batteries are not provided with overcurrent protection features to limit the fault current.</br>A postulated fire that results in a short to ground concurrent with an opposite polarity short from the same battery could result in excessive current flow (i.e., heating) in the ammeter wiring. This excessive current could result in a secondary fire in another fire area. The secondary fire could adversely affect safe shutdown equipment and cause loss of the ability to conduct a safe shutdown as required by 10 CFR 50 Appendix R. The areas affected are the Control Room, Relay Rooms and 460 Volt Switchgear Rooms.</br>This condition is being reported in accordance with 10 CFR 50.72(b)(3)(ii)(B). Interim compensatory measures (i.e., fire watches) have been implemented for the affected areas of the plant.</br>The licensee has notified the NRC Resident Inspector.e has notified the NRC Resident Inspector. +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
100 +
00:00:00, 14 November 2013 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
22:21:24, 24 September 2017 +
16:08:00, 14 November 2013 +
true +
false +
-0.0929 d (-2.23 hours, -0.0133 weeks, -0.00305 months) +
18:22:00, 14 November 2013 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.