Browse wiki

Jump to navigation Jump to search
100  +
Beginning at approximately 1100 hours EDT Beginning at approximately 1100 hours EDT on May 10, 2012, plant personnel will be taking the plant integrated computer system (ICS) out-of-service for planned maintenance. During the time ICS is out-of-service, the Safety Parameter Display System (SPDS), the Emergency Response Data System (ERDS), and the automatic mode calculation of the Computer Aided Dose Assessment Program (CADAP) will be unavailable. The computer outage is scheduled for two hours.</br>In the event of an emergency, plant parameter data will be orally transmitted to the facilities through the Status Board Ring Down circuit with back-up by the Private Branch Exchange, Off Premise Exchange, and various redundant intrafacility circuits throughout the emergency facilities. The dose assessment function will be maintained during the out-of-service time period by manual input of data into CADAP and, if required, by manual</br>calculation. The ability to open and maintain an 'open line' using the Emergency Notification System will not be affected and will be the primary means of transferring plant data to the NRC as a contingency until the ERDS can be returned to service.</br>This event is being reported in accordance with 10 CFR 50.72(b)(3)(xiii). A follow-up notification will be made when the maintenance activities are completed and the equipment is restored. The NRC Resident Inspector has been notified.</br>* * * UPDATE AT 1245 EDT ON 5/10/12 FROM MORSE TO HUFFMAN * * *</br>The maintenance activities were completed as scheduled and the integrated computer system and associated systems SPDS, ERDS and CADAP has been returned to service as of 1238 EDT.</br>The licensee will notify the NRC Resident Inspector. R3DO (Giessner) notified.dent Inspector. R3DO (Giessner) notified.  +
15:00:00, 10 May 2012  +
47,913  +
10:29:00, 10 May 2012  +
15:00:00, 10 May 2012  +
Beginning at approximately 1100 hours EDT Beginning at approximately 1100 hours EDT on May 10, 2012, plant personnel will be taking the plant integrated computer system (ICS) out-of-service for planned maintenance. During the time ICS is out-of-service, the Safety Parameter Display System (SPDS), the Emergency Response Data System (ERDS), and the automatic mode calculation of the Computer Aided Dose Assessment Program (CADAP) will be unavailable. The computer outage is scheduled for two hours.</br>In the event of an emergency, plant parameter data will be orally transmitted to the facilities through the Status Board Ring Down circuit with back-up by the Private Branch Exchange, Off Premise Exchange, and various redundant intrafacility circuits throughout the emergency facilities. The dose assessment function will be maintained during the out-of-service time period by manual input of data into CADAP and, if required, by manual</br>calculation. The ability to open and maintain an 'open line' using the Emergency Notification System will not be affected and will be the primary means of transferring plant data to the NRC as a contingency until the ERDS can be returned to service.</br>This event is being reported in accordance with 10 CFR 50.72(b)(3)(xiii). A follow-up notification will be made when the maintenance activities are completed and the equipment is restored. The NRC Resident Inspector has been notified.</br>* * * UPDATE AT 1245 EDT ON 5/10/12 FROM MORSE TO HUFFMAN * * *</br>The maintenance activities were completed as scheduled and the integrated computer system and associated systems SPDS, ERDS and CADAP has been returned to service as of 1238 EDT.</br>The licensee will notify the NRC Resident Inspector. R3DO (Giessner) notified.dent Inspector. R3DO (Giessner) notified.  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
0.0127 d (0.306 hours, 0.00182 weeks, 4.1855e-4 months)  +
100  +
00:00:00, 10 May 2012  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:04:12, 2 March 2018  +
10:29:00, 10 May 2012  +
false  +
-0.188 d (-4.52 hours, -0.0269 weeks, -0.00619 months)  +
15:00:00, 10 May 2012  +
Safety Parameter Display System and Emergency Response Data System Out of Service  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.
1  +