Browse wiki
Jump to navigation
Jump to search
Nine breast cancer patients were treated w … Nine breast cancer patients were treated with a multi-channel high dose rate afterloader with the incorrect dwell positions input into the afterloader controller. The intended prescription was for 5 mm between dwell positions. The actual input was 2.5 mm between dwell positions. The prescribed dose was for 3400 cGy and the actual dose delivered was approximately 25% less. No adverse clinical effects are expected. </br>The doctors and patients will be notified.</br>* * * UPDATE FROM DR. VIVIAN ARTERBERY TO JOHN SHOEMAKER AT 1507 EST ON 03/07/11 * * * </br>There were a total of eleven breast cancer patients involved. Seven of the eleven patients had small areas of unintended target that received unplanned dose. </br>The doctors and patients have been notified.</br>Notified R3DO (Riemer) and FSME (McIntosh) </br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.necessarily result in harm to the patient. +
21:00:00, 7 February 2011 +
12:05:00, 8 February 2011 +
21:00:00, 7 February 2011 +
Nine breast cancer patients were treated w … Nine breast cancer patients were treated with a multi-channel high dose rate afterloader with the incorrect dwell positions input into the afterloader controller. The intended prescription was for 5 mm between dwell positions. The actual input was 2.5 mm between dwell positions. The prescribed dose was for 3400 cGy and the actual dose delivered was approximately 25% less. No adverse clinical effects are expected. </br>The doctors and patients will be notified.</br>* * * UPDATE FROM DR. VIVIAN ARTERBERY TO JOHN SHOEMAKER AT 1507 EST ON 03/07/11 * * * </br>There were a total of eleven breast cancer patients involved. Seven of the eleven patients had small areas of unintended target that received unplanned dose. </br>The doctors and patients have been notified.</br>Notified R3DO (Riemer) and FSME (McIntosh) </br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.necessarily result in harm to the patient. +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 7 March 2011 +
21-13562-01 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:07:42, 2 March 2018 +
12:05:00, 8 February 2011 +
0.628 d (15.08 hours, 0.0898 weeks, 0.0207 months) +
21:00:00, 7 February 2011 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.