At approximately 1210 on November 12, 2010At approximately 1210 on November 12, 2010, a fire protection assessment identified a potentially unanalyzed condition in the plant's 10CFR50 Appendix R analysis. In the unlikely event of a fire in the main control room or cable spreading room, coincident with a fire induced loss of off site power, in which the control room must be evacuated, Operations personnel would proceed to the Alternate Shutdown System (ASDS) panel to perform required safe shutdown activities. During certain scenarios, High Pressure Coolant Injection (HPCI) may start on a reactor low-low water level signal or on high drywell pressure signal. Since HPCI is not controlled manually from the ASDS, a postulated fire induced short could prevent the HPCI system high reactor water level trip and possibly result in reactor vessel overfill.</br>Operation of the Safety Relief Valves in this condition has not been analyzed. For this scenario, the following unlikely sequence of events is required:</br>1. A fire would have to occur in the main control room or cable spreading room</br>2. The fire would have to be significant enough to require main control room evacuation</br>3. Offsite power would have to be lost</br>4. HPCI would have to initiate</br>5. A fire induced short preventing HPCI from tripping automatically would have to occur</br>Applicable safety systems remain operable, and Operations personnel are trained in procedures to handle complex fire scenarios, including fires in the main control room and cable spreading room. Additionally, the cable spreading room is protected by an automatic Halon fire suppression system.</br>As a precaution, a fire watch has been established as a compensatory measure. This event is being reported under 10CFR50.72(b)(3)(ii)(B).</br>The licensee notified the NRC Resident Inspector.ensee notified the NRC Resident Inspector.  +
18:10:00, 12 November 2010  +
20:42:00, 12 November 2010  +
18:10:00, 12 November 2010  +
At approximately 1210 on November 12, 2010At approximately 1210 on November 12, 2010, a fire protection assessment identified a potentially unanalyzed condition in the plant's 10CFR50 Appendix R analysis. In the unlikely event of a fire in the main control room or cable spreading room, coincident with a fire induced loss of off site power, in which the control room must be evacuated, Operations personnel would proceed to the Alternate Shutdown System (ASDS) panel to perform required safe shutdown activities. During certain scenarios, High Pressure Coolant Injection (HPCI) may start on a reactor low-low water level signal or on high drywell pressure signal. Since HPCI is not controlled manually from the ASDS, a postulated fire induced short could prevent the HPCI system high reactor water level trip and possibly result in reactor vessel overfill.</br>Operation of the Safety Relief Valves in this condition has not been analyzed. For this scenario, the following unlikely sequence of events is required:</br>1. A fire would have to occur in the main control room or cable spreading room</br>2. The fire would have to be significant enough to require main control room evacuation</br>3. Offsite power would have to be lost</br>4. HPCI would have to initiate</br>5. A fire induced short preventing HPCI from tripping automatically would have to occur</br>Applicable safety systems remain operable, and Operations personnel are trained in procedures to handle complex fire scenarios, including fires in the main control room and cable spreading room. Additionally, the cable spreading room is protected by an automatic Halon fire suppression system.</br>As a precaution, a fire watch has been established as a compensatory measure. This event is being reported under 10CFR50.72(b)(3)(ii)(B).</br>The licensee notified the NRC Resident Inspector.ensee notified the NRC Resident Inspector.  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 12 November 2010  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
22:29:09, 24 September 2017  +
20:42:00, 12 November 2010  +
false  +
0.105 d (2.53 hours, 0.0151 weeks, 0.00347 months)  +
18:10:00, 12 November 2010  +
Unanalyzed 10Cfr50 Appendix R Scenario  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.
1  +