At 0911 EDT, the Susquehanna LLC Shift Man … At 0911 EDT, the Susquehanna LLC Shift Manager was notified that a member of the SSES (Susquehanna Steam Electric Station) work force was feeling ill effects from a Freon-12 leak located in a plant vital area. This met the declaration criteria for an Alert under (EAL) OA-7 of the emergency plan which was declared at 0922 EDT.</br>The affected area has been evacuated and recovery actions are in progress to isolate the leak. No personnel were injured or medical attention was required.</br>The leak is in the 1A Reactor Building chiller unit. At the time of notification, the leak was still active. The licensee is preparing a team to enter the area to investigate. No outside assistance is required.</br>Notified DHS (Hill), FEMA (Heyman), DOE (Smith), USDA (Mitchell) and HHS (Rolle).</br>* * * UPDATE FROM DARVIN DUTTRY TO DONALD NORWOOD AT 0044 EDT ON 8/11/2010 * * *</br>At 2335 EDT on 8/10/10, the Alert was terminated. The Chiller has been evacuated of Freon-12. Freon detectors show no presence of Freon-12 on U1 Reactor Building Elevation 749 (feet), except in the immediate vicinity from the leak site with temporary ventilation in service.</br>All state and local agencies have been advised, the NRC Resident Inspector has been notified and a press release will be made.</br>Agencies that the licensee notified included the Columbia County Emergency Management Agency, the Luzerne County Emergency Management Agency, the Pennsylvania Emergency Management Agency and the Pennsylvania Department of Environmental Protection. </br>Notified R1DO (Ferdas), NRR EO (Nelson), IRD Manager (Gott), DHS (Doyle), FEMA (O'Connell), DOE (Morrone), HHS (White), and USDA (Timmons).Morrone), HHS (White), and USDA (Timmons). +
13:11:00, 10 August 2010 +
46,164 +
10:02:00, 10 August 2010 +
13:11:00, 10 August 2010 +
At 0911 EDT, the Susquehanna LLC Shift Man … At 0911 EDT, the Susquehanna LLC Shift Manager was notified that a member of the SSES (Susquehanna Steam Electric Station) work force was feeling ill effects from a Freon-12 leak located in a plant vital area. This met the declaration criteria for an Alert under (EAL) OA-7 of the emergency plan which was declared at 0922 EDT.</br>The affected area has been evacuated and recovery actions are in progress to isolate the leak. No personnel were injured or medical attention was required.</br>The leak is in the 1A Reactor Building chiller unit. At the time of notification, the leak was still active. The licensee is preparing a team to enter the area to investigate. No outside assistance is required.</br>Notified DHS (Hill), FEMA (Heyman), DOE (Smith), USDA (Mitchell) and HHS (Rolle).</br>* * * UPDATE FROM DARVIN DUTTRY TO DONALD NORWOOD AT 0044 EDT ON 8/11/2010 * * *</br>At 2335 EDT on 8/10/10, the Alert was terminated. The Chiller has been evacuated of Freon-12. Freon detectors show no presence of Freon-12 on U1 Reactor Building Elevation 749 (feet), except in the immediate vicinity from the leak site with temporary ventilation in service.</br>All state and local agencies have been advised, the NRC Resident Inspector has been notified and a press release will be made.</br>Agencies that the licensee notified included the Columbia County Emergency Management Agency, the Luzerne County Emergency Management Agency, the Pennsylvania Emergency Management Agency and the Pennsylvania Department of Environmental Protection. </br>Notified R1DO (Ferdas), NRR EO (Nelson), IRD Manager (Gott), DHS (Doyle), FEMA (O'Connell), DOE (Morrone), HHS (White), and USDA (Timmons).Morrone), HHS (White), and USDA (Timmons). +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
100 +
00:00:00, 11 August 2010 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:09:00, 2 March 2018 +
10:02:00, 10 August 2010 +
true +
false +
-0.131 d (-3.15 hours, -0.0187 weeks, -0.00431 months) +
13:11:00, 10 August 2010 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.