Browse wiki
Jump to navigation
Jump to search
The following information was received via … The following information was received via fax:</br>On July 17, 2008 the PA DEP SERO (Pennsylvania Department of Environmental Protection Southeast Regional Office) was notified of a medical event at Lehigh Valley Hospital. Two patients were scheduled for different I-131 therapy doses and the doses got switched. The first patient was prescribed 20 mCi but was administered 75 mCi. The event took place on July 17, 2008. Both the patient and the physician were informed. The patient was given a blocking agent of 130mg SSKI approximately 1 hour after uptake of the I-131. Next day measurements indicated 2 mCi uptake to the thyroid and 10 mCi whole body retention. A procedure modification has been put into place to prevent this from occurring again. Also a Notice of Violation was sent to the hospital.</br>Event Report ID No: PA080021</br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.necessarily result in harm to the patient. +
05:00:00, 17 July 2008 +
45,656 +
22:01:00, 25 January 2010 +
05:00:00, 17 July 2008 +
The following information was received via … The following information was received via fax:</br>On July 17, 2008 the PA DEP SERO (Pennsylvania Department of Environmental Protection Southeast Regional Office) was notified of a medical event at Lehigh Valley Hospital. Two patients were scheduled for different I-131 therapy doses and the doses got switched. The first patient was prescribed 20 mCi but was administered 75 mCi. The event took place on July 17, 2008. Both the patient and the physician were informed. The patient was given a blocking agent of 130mg SSKI approximately 1 hour after uptake of the I-131. Next day measurements indicated 2 mCi uptake to the thyroid and 10 mCi whole body retention. A procedure modification has been put into place to prevent this from occurring again. Also a Notice of Violation was sent to the hospital.</br>Event Report ID No: PA080021</br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.necessarily result in harm to the patient. +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 25 January 2010 +
PA-0232 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
23:24:22, 24 November 2018 +
22:01:00, 25 January 2010 +
557.668 d (13,384.02 hours, 79.667 weeks, 18.333 months) +
05:00:00, 17 July 2008 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.