Browse wiki

Jump to navigation Jump to search
At 1744 (EST) on 1/18/08, (the licensee) eAt 1744 (EST) on 1/18/08, (the licensee) entered Technical Specification (TS) 3.0.3 on Unit 3 due to observed Rod Position lndicator (RPI) F-14 dropping from 228 steps to 135-145 steps and behaving erratically. This RPI is in the same bank as currently inoperable RPI F-2. TS 3.1.3.2 has actions for a maximum of one RPI per bank inoperable. Since there are two inoperable in one bank, an entry into TS 3.0.3 is required. </br>Power reduction (was) initiated at 1835 (hrs.).</br>Repairs (are) currently in progress (and the licensee) anticipate(s) correction prior to completion of power reduction.</br>If the RPI is not corrected, the licensee will be required to be in Mode 3 by 0044 hrs. EST on 01/19/08. This is an ongoing issue. See Event Notifications 43896 and 43888.</br>The licensee has notified the NRC Resident Inspector.</br>* * * UPDATE PROVIDED BY DAVE FUNK TO JASON KOZAL AT 2041 0N 1/18/07 * * *</br>Repairs are complete. RPI F-14 has been restored to service on Unit 3, exited Technical Specification 3.0.3 at 2027. Return to 100% power on Unit 3 (is) in progress.</br>The licensee will notify the NRC Resident Inspector. </br>Notified R2DO (Moorman).ident Inspector. Notified R2DO (Moorman).  +
22:44:00, 18 January 2008  +
43,919  +
18:44:00, 18 January 2008  +
22:44:00, 18 January 2008  +
At 1744 (EST) on 1/18/08, (the licensee) eAt 1744 (EST) on 1/18/08, (the licensee) entered Technical Specification (TS) 3.0.3 on Unit 3 due to observed Rod Position lndicator (RPI) F-14 dropping from 228 steps to 135-145 steps and behaving erratically. This RPI is in the same bank as currently inoperable RPI F-2. TS 3.1.3.2 has actions for a maximum of one RPI per bank inoperable. Since there are two inoperable in one bank, an entry into TS 3.0.3 is required. </br>Power reduction (was) initiated at 1835 (hrs.).</br>Repairs (are) currently in progress (and the licensee) anticipate(s) correction prior to completion of power reduction.</br>If the RPI is not corrected, the licensee will be required to be in Mode 3 by 0044 hrs. EST on 01/19/08. This is an ongoing issue. See Event Notifications 43896 and 43888.</br>The licensee has notified the NRC Resident Inspector.</br>* * * UPDATE PROVIDED BY DAVE FUNK TO JASON KOZAL AT 2041 0N 1/18/07 * * *</br>Repairs are complete. RPI F-14 has been restored to service on Unit 3, exited Technical Specification 3.0.3 at 2027. Return to 100% power on Unit 3 (is) in progress.</br>The licensee will notify the NRC Resident Inspector. </br>Notified R2DO (Moorman).ident Inspector. Notified R2DO (Moorman).  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
100  +
00:00:00, 18 January 2008  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:15:13, 2 March 2018  +
18:44:00, 18 January 2008  +
false  +
-0.167 d (-4 hours, -0.0238 weeks, -0.00548 months)  +
22:44:00, 18 January 2008  +
Technical Specification Required Shutdown Due to Two Inoperable Rod Position Indicators in the Same Rod Group  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.
3  +