On December 10, 2006, at 1608 PST, operato … On December 10, 2006, at 1608 PST, operators manually tripped the reactor while it was subcritical. This is an 8 hour notification per 10 CFR 50.72(b)(3)(iv)(A) for actuation of the reactor protection system while subcritical. On December 10, 2006, with Unit 2 operating in Mode 1 at 100% power, operators initiated an unplanned reactor shutdown due to indications of increasing stator temperature on reactor coolant pump 2-2. In accordance with plant procedures, when the reactor coolant pump stator temperature reached 300 degrees Fahrenheit, operators manually tripped the reactor and tripped the coolant pump 2-2. The reactor was subcritical at the time of the reactor trip but all rods had not been fully inserted. </br>All control rods fully inserted in response to the reactor trip and all systems functioned as required. The auxiliary feedwater system was already in service as part of the shutdown. The grid is stable and with the exception of RCP 2-2, all major equipment including the 3 emergency diesel generators remain operable. Unit 2 electrical loads are being supplied by the normal startup power. The other 3 RCPs are maintaining forced circulation of the reactor coolant system. Investigations into the high RCP stator temperature are ongoing, the unit will remain in Mode 3 pending the results of these investigations. An estimated restart date is not known at this time. The NRC Resident Inspector has been informed and was onsite at the time of the trip. Unit 1 is unaffected and remains in Mode 1.</br>The licensee stated that a press release related to this event is likely.</br>* * * UPDATE TO HUFFMAN DURING PLANT STATUS ON 12/11/06 AT 0419 EST * * *</br>Licensee believes the cause of the high RCP stator temperature was due to a failed RTD.</br>* * * UPDATE FROM L. PARKER TO P. SNYDER AT 1531 ON 12/14/06 * * * </br>Unit 2 was in Mode 3 (Hot Standby) at 0 percent power at the time of the manual trip. At the time of the Initial notification, all procedural requirements for declaring Mode 3 had not been met, but upon further review, PG&E has verified K effective was less than 0.99.</br>The licensee notified the NRC Resident Inspector. Notified R4DO (Proulx).</br>The original report was modified by this change. The 'RX Crit' field was changed from 'Y' to 'N'. The 'Init Power' field was changed from '5' to '0'. The 'Curr Power' field was changed from 'Startup' to 'Hot Standby'.d was changed from 'Startup' to 'Hot Standby'.
00:08:00, 11 December 2006 +
43,042 +
00:31:00, 11 December 2006 +
00:08:00, 11 December 2006 +
On December 10, 2006, at 1608 PST, operato … On December 10, 2006, at 1608 PST, operators manually tripped the reactor while it was subcritical. This is an 8 hour notification per 10 CFR 50.72(b)(3)(iv)(A) for actuation of the reactor protection system while subcritical. On December 10, 2006, with Unit 2 operating in Mode 1 at 100% power, operators initiated an unplanned reactor shutdown due to indications of increasing stator temperature on reactor coolant pump 2-2. In accordance with plant procedures, when the reactor coolant pump stator temperature reached 300 degrees Fahrenheit, operators manually tripped the reactor and tripped the coolant pump 2-2. The reactor was subcritical at the time of the reactor trip but all rods had not been fully inserted. </br>All control rods fully inserted in response to the reactor trip and all systems functioned as required. The auxiliary feedwater system was already in service as part of the shutdown. The grid is stable and with the exception of RCP 2-2, all major equipment including the 3 emergency diesel generators remain operable. Unit 2 electrical loads are being supplied by the normal startup power. The other 3 RCPs are maintaining forced circulation of the reactor coolant system. Investigations into the high RCP stator temperature are ongoing, the unit will remain in Mode 3 pending the results of these investigations. An estimated restart date is not known at this time. The NRC Resident Inspector has been informed and was onsite at the time of the trip. Unit 1 is unaffected and remains in Mode 1.</br>The licensee stated that a press release related to this event is likely.</br>* * * UPDATE TO HUFFMAN DURING PLANT STATUS ON 12/11/06 AT 0419 EST * * *</br>Licensee believes the cause of the high RCP stator temperature was due to a failed RTD.</br>* * * UPDATE FROM L. PARKER TO P. SNYDER AT 1531 ON 12/14/06 * * * </br>Unit 2 was in Mode 3 (Hot Standby) at 0 percent power at the time of the manual trip. At the time of the Initial notification, all procedural requirements for declaring Mode 3 had not been met, but upon further review, PG&E has verified K effective was less than 0.99.</br>The licensee notified the NRC Resident Inspector. Notified R4DO (Proulx).</br>The original report was modified by this change. The 'RX Crit' field was changed from 'Y' to 'N'. The 'Init Power' field was changed from '5' to '0'. The 'Curr Power' field was changed from 'Startup' to 'Hot Standby'.d was changed from 'Startup' to 'Hot Standby'.
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 14 December 2006 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:17:30, 2 March 2018 +
00:31:00, 11 December 2006 +
false +
true +
0.0158 d (0.38 hours, 0.00226 weeks, 5.20524e-4 months) +
00:08:00, 11 December 2006 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.