On July 29, 2004, at approximately 0351 hoOn July 29, 2004, at approximately 0351 hours, testing of Suppression Chamber-to-Drywell vacuum breakers commenced in accordance with Periodic Test 0PT02.3.1, "Suppression Chamber-to-Drywell Vacuum Breaker Operability Test." At 0357 hours, it was determined that vacuum breaker 2-CAC-X18D had an open indication. Technical Specifications (TS) Limiting Condition for Operation (LCO) 3.6.1.6, "Suppression Chamber-to-Drywell Vacuum Breakers," Condition B was entered for one suppression chamber-to-drywell vacuum breaker (2-CAC-X18D) not indicating closed. Required Action B.1 of TS LCO 3.6.1.6 provides 4 hours to verify the vacuum breaker closed. Attempts to confirm the vacuum breaker closed were unsuccessful and at 0757 hours, TS LCO 3.6.1.6 Condition C was entered. Required Action C.1 is to be in Mode 3 (Hot Shutdown) in 12 hours and Required Action C.2 is to be in Mode 4 (Cold Shutdown) in 36 hours. Initiation of the plant shutdown required by TS LCO 3.6.1.6 commenced at 0942 hours.</br>This condition is being reported in accordance with 10 CFR 50.72(b)(2)(i) as the initiation of any nuclear plant shutdown required by the plant's TS. </br>INITIAL SAFETY SIGNIFICANCE EVALUATION</br>The initial safety significance of this condition is considered to be minimal. The actual position of the vacuum breaker cannot be confirmed, however if one vacuum breaker was not closed, communication between the drywell and suppression chamber air space could occur, and as a result, there is a potential, for primary containment overpressurization due to this bypass leakage if a loss of coolant accident were to occur. The plant is currently proceeding to hot shutdown with all Emergency Core Cooling systems operable.</br>CORRECTIVE ACTIONS</br>Determine the required corrective actions after entry into the drywell following shutdown. The safety significance of the event will be reviewed when the actual condition of the vacuum breaker is known.</br>The NRC Resident Inspector has been notified.</br>* * * UPDATE ON 07/29/04 @ 1654 FROM KEN CHISM TO CHAUNCEY GOULD * * * </br>On July 29, 2004, at 1517 hours, a manual scram was inserted to shut down the Unit 2 reactor from approximately 23 percent of rated thermal power. The reactor shutdown was implemented to meet the requirements of Technical Specification (TS) Limiting Condition for Operation (LCO) 3.6.1.6 Required Action C.1 to be in Mode 3 in 12 hours. All control rods fully inserted into the core and no ECCS actuation occurred or relief valves lifted. Following the scram, an expected reactor vessel coolant level shrink occurred causing coolant level to decrease below the Low Level 1 setpoint. This coolant level decrease resulted in a Primary Containment Isolation Valve isolation signal to Group 2 (Drywell Equipment and Floor Drain, Traversing In-core Probe, Residual Heat Removal (RHR) Discharge to Radwaste, and RHR Process Sample), Group 6 (Containment Atmosphere Control/Dilution, Containment Atmosphere Monitoring, and Post Accident Sampling System), and Group 8 (RHR Shutdown Cooling Suction and RHR Inboard Injection) isolation valves. The isolation signal closed all of the valves that were open at the time of the expected initiation.</br>The plant is currently in mode 3 and proceeding with a normal cooldown to Mode 4.</br>The NRC Resident Inspection was informed.</br>Notified Reg 2 RDO (Tom Decker).informed. Notified Reg 2 RDO (Tom Decker).  
13:42:00, 29 July 2004  +
40,905  +
12:14:00, 29 July 2004  +
13:42:00, 29 July 2004  +
On July 29, 2004, at approximately 0351 hoOn July 29, 2004, at approximately 0351 hours, testing of Suppression Chamber-to-Drywell vacuum breakers commenced in accordance with Periodic Test 0PT02.3.1, "Suppression Chamber-to-Drywell Vacuum Breaker Operability Test." At 0357 hours, it was determined that vacuum breaker 2-CAC-X18D had an open indication. Technical Specifications (TS) Limiting Condition for Operation (LCO) 3.6.1.6, "Suppression Chamber-to-Drywell Vacuum Breakers," Condition B was entered for one suppression chamber-to-drywell vacuum breaker (2-CAC-X18D) not indicating closed. Required Action B.1 of TS LCO 3.6.1.6 provides 4 hours to verify the vacuum breaker closed. Attempts to confirm the vacuum breaker closed were unsuccessful and at 0757 hours, TS LCO 3.6.1.6 Condition C was entered. Required Action C.1 is to be in Mode 3 (Hot Shutdown) in 12 hours and Required Action C.2 is to be in Mode 4 (Cold Shutdown) in 36 hours. Initiation of the plant shutdown required by TS LCO 3.6.1.6 commenced at 0942 hours.</br>This condition is being reported in accordance with 10 CFR 50.72(b)(2)(i) as the initiation of any nuclear plant shutdown required by the plant's TS. </br>INITIAL SAFETY SIGNIFICANCE EVALUATION</br>The initial safety significance of this condition is considered to be minimal. The actual position of the vacuum breaker cannot be confirmed, however if one vacuum breaker was not closed, communication between the drywell and suppression chamber air space could occur, and as a result, there is a potential, for primary containment overpressurization due to this bypass leakage if a loss of coolant accident were to occur. The plant is currently proceeding to hot shutdown with all Emergency Core Cooling systems operable.</br>CORRECTIVE ACTIONS</br>Determine the required corrective actions after entry into the drywell following shutdown. The safety significance of the event will be reviewed when the actual condition of the vacuum breaker is known.</br>The NRC Resident Inspector has been notified.</br>* * * UPDATE ON 07/29/04 @ 1654 FROM KEN CHISM TO CHAUNCEY GOULD * * * </br>On July 29, 2004, at 1517 hours, a manual scram was inserted to shut down the Unit 2 reactor from approximately 23 percent of rated thermal power. The reactor shutdown was implemented to meet the requirements of Technical Specification (TS) Limiting Condition for Operation (LCO) 3.6.1.6 Required Action C.1 to be in Mode 3 in 12 hours. All control rods fully inserted into the core and no ECCS actuation occurred or relief valves lifted. Following the scram, an expected reactor vessel coolant level shrink occurred causing coolant level to decrease below the Low Level 1 setpoint. This coolant level decrease resulted in a Primary Containment Isolation Valve isolation signal to Group 2 (Drywell Equipment and Floor Drain, Traversing In-core Probe, Residual Heat Removal (RHR) Discharge to Radwaste, and RHR Process Sample), Group 6 (Containment Atmosphere Control/Dilution, Containment Atmosphere Monitoring, and Post Accident Sampling System), and Group 8 (RHR Shutdown Cooling Suction and RHR Inboard Injection) isolation valves. The isolation signal closed all of the valves that were open at the time of the expected initiation.</br>The plant is currently in mode 3 and proceeding with a normal cooldown to Mode 4.</br>The NRC Resident Inspection was informed.</br>Notified Reg 2 RDO (Tom Decker).informed. Notified Reg 2 RDO (Tom Decker).  
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
0.00406 d (0.0975 hours, 5.803571e-4 weeks, 1.335555e-4 months)  +, 0.00413 d (0.0992 hours, 5.902778e-4 weeks, 1.358385e-4 months)  +, 4.62963e-5 d (0.00111 hours, 6.613757e-6 weeks, 1.522e-6 months)  +, 0.00876 d (0.21 hours, 0.00125 weeks, 2.880385e-4 months)  +, 1.388889e-4 d (0.00333 hours, 1.984127e-5 weeks, 4.566e-6 months)  +, 4.166667e-4 d (0.01 hours, 5.952381e-5 weeks, 1.3698e-5 months)  +, 0.0109 d (0.262 hours, 0.00156 weeks, 3.58431e-4 months)  +  and 0.0176 d (0.421 hours, 0.00251 weeks, 5.772185e-4 months)  +
00:00:00, 29 July 2004  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:23:06, 2 March 2018  +
12:14:00, 29 July 2004  +
false  +
-0.0613 d (-1.47 hours, -0.00875 weeks, -0.00201 months)  +
13:42:00, 29 July 2004  +
Plant Entered Lco Action Statement Due to Malfunction of a Suppression Chamber-To-Drywell Vacuum Breaker.  +