On August 13, 2015, at approximately 2106, … On August 13, 2015, at approximately 2106, the Unit 3 main steam isolation valve SGE-UV-181 (MSIV-181) B actuator train was declared inoperable and Technical Specification (TS) Limiting Condition for Operation (LCO) 3.7.2, Condition A, was entered due to a failed fitting on the air supply line. To correct the condition the failed fitting was replaced and an additional pipe support was installed on the air-line. Following retests, the MSIV-181 B actuator train was restored to operable status and LCO 3.7.2, Condition A, was exited on August 15, 2015, at approximately 1830.</br></br>A similar air-line fitting failure had occurred on the Unit 3 MSIV-181 B actuator train on May 19, 2015. The investigation of this condition following the second failure determined the MSIV-181 B actuator train air-line configuration was modified in the spring 2015 Unit 3 refueling outage and was inoperable from the time Unit 3 entered Mode 4 on May 1, 2015, at 0258, following the outage because the air-line tubing was not adequately supported following the design change.</br></br>The investigation of the two fitting failures is still in progress. The cause of this condition and any additional corrective actions will be reported in a supplement to this Licensee Event Report.</br></br>No similar conditions have been reported by PVNGS in the last three years.reported by PVNGS in the last three years. +
May 1, 2015 +
On August 13, 2015, at approximately 2106, … On August 13, 2015, at approximately 2106, the Unit 3 main steam isolation valve SGE-UV-181 (MSIV-181) B actuator train was declared inoperable and Technical Specification (TS) Limiting Condition for Operation (LCO) 3.7.2, Condition A, was entered due to a failed fitting on the air supply line. To correct the condition the failed fitting was replaced and an additional pipe support was installed on the air-line. Following retests, the MSIV-181 B actuator train was restored to operable status and LCO 3.7.2, Condition A, was exited on August 15, 2015, at approximately 1830.</br></br>A similar air-line fitting failure had occurred on the Unit 3 MSIV-181 B actuator train on May 19, 2015. The investigation of this condition following the second failure determined the MSIV-181 B actuator train air-line configuration was modified in the spring 2015 Unit 3 refueling outage and was inoperable from the time Unit 3 entered Mode 4 on May 1, 2015, at 0258, following the outage because the air-line tubing was not adequately supported following the design change.</br></br>The investigation of the two fitting failures is still in progress. The cause of this condition and any additional corrective actions will be reported in a supplement to this Licensee Event Report.</br></br>No similar conditions have been reported by PVNGS in the last three years.reported by PVNGS in the last three years. +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000530/LER-2015-004, Condition Prohibited by Technical Specifications 3.0.4 and 3.7.2 Due to an Inoperable Main Steam Isolation Valve +, 05000530/LER-2015-004, Condition Prohibited by Technical Specifications 3.0.4 and 3.7.2 Due to an Inoperable Main Steam Isolation Valve +, 05000530/LER-2015-004, Condition Prohibited by Technical Specifications 3.0.4 and 3.7.2 Due to an Inoperable Main Steam Isolation Valve + and 05000530/LER-2015-004, Condition Prohibited by Technical Specifications 3.0.4 and 3.7.2 Due to an Inoperable Main Steam Isolation Valve +
4 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
14:54:23, 7 August 2016 +
October 9, 2015 +
May 1, 2015 +
Condition Prohibited by Technical Specifications 3.0.4 and 3.7.2 Due to an Inoperable Main Steam Isolation Valve +