The team documented a Green self-revealingThe team documented a Green self-revealing violation of Technical Specification 5.4.1(a), Procedures, because operators failed to meet the conditions of a plant clearance order before opening main steam line drain valves. Consequently, operators inadvertently drained approximately 4300 gallons of reactor coolant to the under-vessel sump. Contributors to the violation included: 1) the reactor vessel assembly procedure was inadequate, in that it permitted maintenance personnel to place the reactor vessel level instruments in an uncalibrated condition; and 2) plant operators failed to follow operational performance standards when they were advised of the condition and proceeded to lower reactor vessel level for approximately 40 hours with inaccurate reactor vessel level instruments. The licensee entered the violation into the corrective action program as Action Request 245507. The finding was more than minor because it affected the human performance attribute of the Mitigating Systems Cornerstone and affected the cornerstone objective to ensure the availability, reliability, and capability of reactor vessel level instruments that are used to respond to initiating events to prevent undesirable consequences (i.e., core damage). The inspectors used NRC Inspection Manual 0609, Appendix G, Shutdown Operations Significance Determination Process, to evaluate the significance of the finding. The finding did not require a quantitative assessment because adequate mitigating equipment remained available and the finding did not constitute a loss of control, as defined in Appendix G. Therefore, the finding screened as Green. The finding had a crosscutting aspect in the area of human performance associated with Work Practices because plant personnel, once faced with unexpected circumstances, continued to proceed in the face of uncertainty.ued to proceed in the face of uncertainty.  +
23:59:59, 31 December 2011  +
05000397  +
23:59:59, 31 December 2011  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
4.62963e-4 d (0.0111 hours, 6.613757e-5 weeks, 1.522e-5 months)  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
12:57:33, 25 September 2017  +
23:59:59, 31 December 2011  +
Failure to Follow Clearance Order Instructions  +