ML20080U557 +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000373/LER-1995-002-05, :on 950208,Unit 1 Reactor Shutdown Commenced Due to Inability to Isolate Inboard Steam Supply to Rcic. PCIS Valve 1E51-F063 Declared Inoperable & Outboard Isolation Valve 1E51-F007 Closed & Deactivated +, 05000373/LER-1995-002-05, :on 950208,Unit 1 Reactor Shutdown Commenced Due to Inability to Isolate Inboard Steam Supply to Rcic. PCIS Valve 1E51-F063 Declared Inoperable & Outboard Isolation Valve 1E51-F007 Closed & Deactivated +, 05000373/LER-1995-002-05, :on 950208,Unit 1 Reactor Shutdown Commenced Due to Inability to Isolate Inboard Steam Supply to Rcic. PCIS Valve 1E51-F063 Declared Inoperable & Outboard Isolation Valve 1E51-F007 Closed & Deactivated +, 05000373/LER-1995-002-05, :on 950208,Unit 1 Reactor Shutdown Commenced Due to Inability to Isolate Inboard Steam Supply to Rcic. PCIS Valve 1E51-F063 Declared Inoperable & Outboard Isolation Valve 1E51-F007 Closed & Deactivated +, 05000373/LER-1995-002-05, :on 950208,Unit 1 Reactor Shutdown Commenced Due to Inability to Isolate Inboard Steam Supply to Rcic. PCIS Valve 1E51-F063 Declared Inoperable & Outboard Isolation Valve 1E51-F007 Closed & Deactivated +, 05000373/LER-1995-002-05, :on 950208,Unit 1 Reactor Shutdown Commenced Due to Inability to Isolate Inboard Steam Supply to Rcic. PCIS Valve 1E51-F063 Declared Inoperable & Outboard Isolation Valve 1E51-F007 Closed & Deactivated +, 05000373/LER-1995-002-05, :on 950208,Unit 1 Reactor Shutdown Commenced Due to Inability to Isolate Inboard Steam Supply to Rcic. PCIS Valve 1E51-F063 Declared Inoperable & Outboard Isolation Valve 1E51-F007 Closed & Deactivated +, 05000373/LER-1995-002-05, :on 950208,Unit 1 Reactor Shutdown Commenced Due to Inability to Isolate Inboard Steam Supply to Rcic. PCIS Valve 1E51-F063 Declared Inoperable & Outboard Isolation Valve 1E51-F007 Closed & Deactivated +, 05000373/LER-1995-002-05, :on 950208,Unit 1 Reactor Shutdown Commenced Due to Inability to Isolate Inboard Steam Supply to Rcic. PCIS Valve 1E51-F063 Declared Inoperable & Outboard Isolation Valve 1E51-F007 Closed & Deactivated +, 05000373/LER-1995-002-05, :on 950208,Unit 1 Reactor Shutdown Commenced Due to Inability to Isolate Inboard Steam Supply to Rcic. PCIS Valve 1E51-F063 Declared Inoperable & Outboard Isolation Valve 1E51-F007 Closed & Deactivated +, 05000373/LER-1995-002-05, :on 950208,Unit 1 Reactor Shutdown Commenced Due to Inability to Isolate Inboard Steam Supply to Rcic. PCIS Valve 1E51-F063 Declared Inoperable & Outboard Isolation Valve 1E51-F007 Closed & Deactivated +, 05000373/LER-1995-002-05, :on 950208,Unit 1 Reactor Shutdown Commenced Due to Inability to Isolate Inboard Steam Supply to Rcic. PCIS Valve 1E51-F063 Declared Inoperable & Outboard Isolation Valve 1E51-F007 Closed & Deactivated +, 05000373/LER-1995-002-05, :on 950208,Unit 1 Reactor Shutdown Commenced Due to Inability to Isolate Inboard Steam Supply to Rcic. PCIS Valve 1E51-F063 Declared Inoperable & Outboard Isolation Valve 1E51-F007 Closed & Deactivated +, 05000373/LER-1995-002-05, :on 950208,Unit 1 Reactor Shutdown Commenced Due to Inability to Isolate Inboard Steam Supply to Rcic. PCIS Valve 1E51-F063 Declared Inoperable & Outboard Isolation Valve 1E51-F007 Closed & Deactivated +, 05000373/LER-1995-002-05, :on 950208,Unit 1 Reactor Shutdown Commenced Due to Inability to Isolate Inboard Steam Supply to Rcic. PCIS Valve 1E51-F063 Declared Inoperable & Outboard Isolation Valve 1E51-F007 Closed & Deactivated +, 05000373/LER-1995-002-05, :on 950208,Unit 1 Reactor Shutdown Commenced Due to Inability to Isolate Inboard Steam Supply to Rcic. PCIS Valve 1E51-F063 Declared Inoperable & Outboard Isolation Valve 1E51-F007 Closed & Deactivated +, 05000373/LER-1995-002-05, :on 950208,Unit 1 Reactor Shutdown Commenced Due to Inability to Isolate Inboard Steam Supply to Rcic. PCIS Valve 1E51-F063 Declared Inoperable & Outboard Isolation Valve 1E51-F007 Closed & Deactivated + and 05000373/LER-1995-002-05, :on 950208,Unit 1 Reactor Shutdown Commenced Due to Inability to Isolate Inboard Steam Supply to Rcic. PCIS Valve 1E51-F063 Declared Inoperable & Outboard Isolation Valve 1E51-F007 Closed & Deactivated +
March 8, 1995 +
2 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
13:28:57, 14 December 2024 +
NRC Form 3MA + and NRC Form 3 +
5 +
March 8, 1995 +
:on 950208,Unit 1 Reactor Shutdown Commenced Due to Inability to Isolate Inboard Steam Supply to Rcic. PCIS Valve 1E51-F063 Declared Inoperable & Outboard Isolation Valve 1E51-F007 Closed & Deactivated
+
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.