Browse wiki

Jump to navigation Jump to search
The team identified a non-cited violation The team identified a non-cited violation of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, for the licensees failure to follow plant procedures specifying requirements for preventive maintenance of safety-related dampers. This failure to follow plant procedures was a performance deficiency. The licensee entered this issue into their corrective action program as nuclear condition reports 631376, 628132, 633710, and 631711. The licensee performed an immediate determination of operability to verify the as-found condition of the dampers did not affect operability of equipment inside the diesel generator building and implemented corrective actions to complete the missed preventive maintenance on the dampers. The performance deficiency was determined to be more than minor because it was associated with the Equipment Performance attribute of the Mitigating Systems cornerstone and adversely affected the cornerstone objective of ensuring availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the programmatic failure to perform preventive maintenance on the nine dampers resulted in decreased availability and reliability of the dampers such that multiple dampers were found in degraded conditions. The team determined the finding to be of very low safety significance (Green) because the finding did not result in an actual loss of function of at least a single emergency diesel generator for greater than its technical specifications allowed outage time. The team determined that this finding was associated with the cross-cutting aspect of Supervisory Oversight in the Work Practices component of the Human Performance area because Brunswick supervisors did not enforce the scheduled preventive maintenance nor did they ensure a justification for not performing preventive maintenance on safety-related components. maintenance on safety-related components.  +
23:59:59, 31 December 2013  +
05000324  +  and 05000325  +
23:59:59, 31 December 2013  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
03:48:27, 28 September 2017  +
23:59:59, 31 December 2013  +
Failure to Follow Plant Procedure Directing the Performance of Preventive Maintenance on Safety-related Dampers  +