The team identified a Green non-cited viol … The team identified a Green non-cited violation of 10 CFR Part 50, Appendix B, Criterion III, Design Control, which states, in part, measures shall be established to assure that applicable regulatory requirements and the design basis are correctly translated into specifications, drawings, procedures and instructions. Specifically, as of July 11, 2013, the licensee failed to evaluate the effects of pump load on the auxiliary feedwater pump motor for the design basis maximum flow conditions that could occur during a postulated steam line break coincident with maximum diesel generator frequency which could have affected the capability of safety-related equipment to respond to initiating events. This finding was entered into the corrective action program as Notification DN-50572850. The team determined that the failure to evaluate the capability of auxiliary feedwater pump motors for the design basis accident maximum pump brake horsepower condition coincident with the maximum diesel generator frequency, which could result in a motor overload, was a performance deficiency. The performance deficiency was more than minor because it was associated with the design control attribute of the Mitigating Systems Cornerstone and affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, there was no analysis or test that demonstrated the motors would be capable of operating for the required mission time during a high energy line break, which resulted in maximum pump brake horsepower conditions that could occur coincident with maximum diesel engine frequency. Using Inspection Manual Chapter 0609, Significance Determination Process, Appendix A, the finding was determined to have very low safety significance (Green) because the finding was a design or qualification deficiency that did not result in the loss of operability or functionality, did not result in a loss of safety function, and did not screen as potentially risk significant due to external events. This finding did not have a cross-cutting aspect because the most significant contributor did not reflect current licensee performance. not reflect current licensee performance.
23:59:59, 30 September 2013 +
23:59:59, 30 September 2013 +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000275/FIN-2013007-02 +, 05000275/FIN-2013007-02 +, 05000275/FIN-2013007-02 +, 05000275/FIN-2013007-02 +, 05000275/FIN-2013007-02 +, 05000275/FIN-2013007-02 +, 05000275/FIN-2013007-02 +, 05000275/FIN-2013007-02 +, 05000275/FIN-2013007-02 +, 05000275/FIN-2013007-02 +, 05000275/FIN-2013007-02 +, 05000275/FIN-2013007-02 +, 05000275/FIN-2013007-02 +, 05000275/FIN-2013007-02 +, 05000275/FIN-2013007-02 +, 05000275/FIN-2013007-02 +, 05000275/FIN-2013007-02 +, 05000275/FIN-2013007-02 +, 05000275/FIN-2013007-02 +, 05000275/FIN-2013007-02 +, 05000275/FIN-2013007-02 +, 05000275/FIN-2013007-02 +, 05000275/FIN-2013007-02 +, 05000275/FIN-2013007-02 +, 05000275/FIN-2013007-02 + and 05000275/FIN-2013007-02 +
Thomas Farnholtz +, R Latta +, S Kobylarz +, J Watkins +, C Hale +, B Sherbin + and Clyde Osterholtz +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
03:48:22, 28 September 2017 +
Thomas Farnholtz +, R Latta +, S Kobylarz +, J Watkins +, C Hale +, B Sherbin + and Clyde Osterholtz +
23:59:59, 30 September 2013 +
Failure to Evaluate the Auxiliary Feedwater Pump Motor Capability for the Effects of Pump Maximum Brake Horsepower Conditions +