Introduction: The inspectors identified anIntroduction: The inspectors identified an URI associated with the failure mechanism of the 42 -2/RPS control rod clutch breaker failure to open. Specifically, at the end of the inspection period the licensee was working to understand the cause of the breaker failure and determine the actions required to address the failure mechanism. Description : On May 17, 2017, the licensee conducted a shutdown to complete emergent repairs to a leaking seal identified on control rod drive mechanism 40. In accordance with GOP 8, Power Reduction and Plant Shutdown to Mode 2 or Mode 3 525 F, the operators depressed the reactor trip pushbutton from the EC 06, reactor protection system panel. When the pushbutton was depressed, the reactor did not trip as expected. The operators successfully tripped the reactor using the reactor trip pushbutton on the EC 02, primary process and reactor controls console. The licensee identified that the 42 1/RPS breaker tripped as expected when the reactor trip pushbutton on the EC 06 panel was depressed, however, the 42 2/RPS breaker did not trip as expected. This resulted in the reactor trip not occurring as expected when the reactor trip pushbutton on the EC 06 panel was depressed as both breakers a re required to open to result in a reactor trip. The licensee performed troubleshooting activities to determine the cause of the 42 2/RPS breaker failure. The direct cause of the breaker failure was found to be the 42 2/RPS breaker undervoltage release mechanism failing to provide enough downward force to fully depress the trip plunger. This resulted in a physical failure of the breaker to open. At the end of the inspection period, the cause of this physical failure mode was unknown. The licensees equipment failure evaluation identified that it could be age- related degradation or a physical degradation of the breaker. As a corrective action, a failure analysis of the breaker was planned. Once the failure analysis i s complete, the licensee plans to re-assess the failure mechanism and determine any additional corrective actions that are required to address the issue. This item is considered unresolved, pending the inspectors review of the failure analysis and any changes made to the equipment failure evaluation, to determine if this issue constitutes a performance deficiency and/or violation of NRC requirements. (URI 05000255/2017003 02, Cause of 42 2/Reactor Protection System Breaker Failure to Open)Protection System Breaker Failure to Open)  
23:59:59, 30 September 2017  +
05000255  +
23:59:59, 30 September 2017  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
03:18:39, 17 November 2017  +
23:59:59, 30 September 2017  +
Cause of 422/RPS Breaker Failure to Open  +