Semantic search
Jump to navigation
Jump to search
Issue date | From | Title | Project stage | |
---|---|---|---|---|
ML16355A346 | 14 December 2016 | Dominion Mark D. Sartain | Proposed Alternative to ASME Section XI Requirements for Repair/Replacement of Circulating and Service Water Class 3 Buried Piping in Accordance with 10 CFR 50.55a(Z)(1) | Request |
ML17033A283 | 6 February 2017 | Cotton K Plant Licensing Branch II | Supplemental Information Needed for Acceptance of Requested Licensing Action Proposed Alternative to ASME Section XI Requirements in Accordance with 10CFR 50.55a(z)(1) | Acceptance Review |
ML17031A130 | 23 February 2017 | Cotton K Plant Licensing Branch II | Request for Withholding Information from Public Disclosure | Withholding Request Acceptance |
ML17055C360 | 23 February 2017 | Dominion Mark D. Sartain | Submittal of Supplement to Proposed Alternative to ASME Section XI, Requirements for Repair/Replacement of Buried Circulating and Service Water Class 3 Piping with Carbon Fiber Reinforced Polymer | Supplement |
ML17030A081 | 24 February 2017 | Cotton K Plant Licensing Branch II | Request for Withholding Information from Public Disclosure | Withholding Request Acceptance |
ML17251A900 | 5 June 2017 | Miller Pipeline | Enclosure 2, Attachment E to 17-296, WEKO-SEAL - Recommended Installation Procedures for Water and Waste-Water Piping, Miller Pipeline, Revised 03/05/17 | Request |
ML17156A083 | 3 July 2017 | Gross K Plant Licensing Branch II | Non-Prop RAI - Regarding Proposed Alternative to ASME Section XI Requirements for Repair/Replacement of Circulating and Service Water Class 3 Buried Piping in Accordance with 10 CFR 50.55a(z)(1) (CAC Nos. MF8987-88) | RAI |
ML17251A895 | 31 August 2017 | Dominion Mark D. Sartain | Proposed Alternative to ASME Section XI Requirements for Repair/Replacement of Buried Circulating and Service Water Class 3 Piping with Carbon Fiber Reinforced Polymer Response to Request for Additional Information | Response to RAI |
ML17264A227 | 20 October 2017 | Gross K Plant Licensing Branch II | Request for Withholding Information from Public Disclosure | Withholding Request Acceptance |
ML17277A296 | 2 November 2017 | Cotton K Plant Licensing Branch II | Request for Withholding Information from Public Disclosure (CAC Nos. MF8987 and MF8988; EPID L-2016-LLR-0019) | Withholding Request Acceptance |
ML17303A068 | 20 December 2017 | Markley M Plant Licensing Branch II | Nonproprietary Relief from the Requirements of the ASME Code (CAC Nos. MF8987 and MF8988; EPID L-2016-LLR-0019) | Approval |
ML18068A064 | 26 March 2018 | Cotton K Plant Licensing Branch II | Relief from the Requirements of the ASME Code Repair/Replacement of Buried Circulating and Service Water Class 3 Piping with Carbon Fiber Reinforced Polymer (CAC Nos. MF8987 and MF8988; EPID L-2016-LLR-0019) | Approval |