Semantic search
Jump to navigation
Jump to search
Issue date | Title | From | To | |
---|---|---|---|---|
NRC Generic Letter 1995-07 | 17 August 1995 | NRC Generic Letter 1995-007: Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves | Crutchfield D Office of Nuclear Reactor Regulation | |
ML20093K747 | 9 October 1995 | Responds to GL 95-07, Pressure Locking & Thermal Binding of Safety-Related Power-Operated Gate Valves | WEC Energy Group Link B | Office of Information Resources Management |
ML20094K918 | 13 November 1995 | Responds to NRC 951103 Reply to Util 951009 60-day Response to GL 95-07, Pressure Locking & Thermal Binding of Safety- Related Power-Operated Gate Valves | WEC Energy Group Link B | Office of Information Resources Management |
Information Notice 1996-05, Partial Bypass of Shutdown Cooling Flow from Reactor Vessel | 18 January 1996 | Partial Bypass of Shutdown Cooling Flow from Reactor Vessel | Crutchfield D Office of Nuclear Reactor Regulation | |
Information Notice 1996-08, Thermally Induced Pressure Locking of a High Pressure Coolant Injection Gate Valve | 5 February 1996 | Thermally Induced Pressure Locking of a High Pressure Coolant Injection Gate Valve | Crutchfield D Office of Nuclear Reactor Regulation | |
ML20100J561 | 9 February 1996 | Responds to GL 95-07, Pressure Locking & Thermal Binding of Safety-Related Power-Operated Gate Valves | WEC Energy Group Link B | Office of Information Resources Management |
ML20115H324 | 1 July 1996 | Rev 1 to Evaluation of SI-860,SI-857 & RC-515/516 Bonnet Pressurization | WEC Energy Group Ruiz T | |
ML20115H320 | 17 July 1996 | Responds to RAI to Assist in Review & Evaluation of GL 95-07, Pressure Locking & Thermal Binding of SR Power Operated Gate Valves | WEC Energy Group Link B | Office of Information Resources Management |
Information Notice 1996-49, Thermally Induced Pressurization of Nuclear Power Facility Piping | 20 August 1996 | Thermally Induced Pressurization of Nuclear Power Facility Piping | Martin T Office of Nuclear Reactor Regulation | |
Information Notice 1997-07, Problems Identified During Generic Letter 89-10 Closeout Inspections | 6 March 1997 | Problems Identified During Generic Letter 89-10 Closeout Inspections | Martin T Office of Nuclear Reactor Regulation | |
L-97-526, Provides Suppl Info for GL 95-07, Pressure Locking & Thermal Binding of SR Power-Operated Gate Valves | 27 August 1997 | Provides Suppl Info for GL 95-07, Pressure Locking & Thermal Binding of SR Power-Operated Gate Valves | WEC Energy Group Dante Johnson | Office of Information Resources Management |
NPL-97-0526, Provides Suppl Info for GL 95-07, Pressure Locking & Thermal Binding of SR Power-Operated Gate Valves | 27 August 1997 | Provides Suppl Info for GL 95-07, Pressure Locking & Thermal Binding of SR Power-Operated Gate Valves | WEC Energy Group Dante Johnson | Office of Information Resources Management |
NPL-98-0110, 1997 Annual Results & Data Rept for Pbnp,Units 1 & 2. W/ | 31 December 1997 | 1997 Annual Results & Data Rept for Pbnp,Units 1 & 2. W/ | WEC Energy Group Dante Johnson | Office of Information Resources Management |
ML20198L115 | 8 January 1998 | SER Accepting Licensee Response to GL 95-07, Pressure Locking & Thermal Binding of Safety-Related Power-Operated Gate Valves, for Point Beach Nuclear Plant,Units 1 & 2 | NRC (Affiliation Not Assigned) | |
ML20198L104 | 8 January 1998 | Forwards SER Re 960209,0717 & 0827 Ltrs Addressing GL 95-07, Pressure Locking & Thermal Binding of Safety-Related Power-Operated Relief Valves, for Point Beach Nuclear Plant Units 1 & 2.Response Adequately Addressed Requested Action | NRC (Affiliation Not Assigned) Gundrum L | WEC Energy Group Grigg R |
NPL-99-0242, Submits Commitment Schedule Update,Per GL 95-07 Re Pressure Locking & Thermal Binding of safety-related power-operated Gate Valves.Unit 1 Block Valve Replacement Will Be Performed During Upcoming 1999 U1R25 Outage | 27 April 1999 | Submits Commitment Schedule Update,Per GL 95-07 Re Pressure Locking & Thermal Binding of safety-related power-operated Gate Valves.Unit 1 Block Valve Replacement Will Be Performed During Upcoming 1999 U1R25 Outage | Kaminskas V WEC Energy Group | Office of Information Resources Management |
NRC 2002-0075, Responses to Request for Additional Information License Amendment Request 226, Measurement Uncertainty Recapture Power Uprate | 29 August 2002 | Responses to Request for Additional Information License Amendment Request 226, Measurement Uncertainty Recapture Power Uprate | Nuclear Management Co Cayia A | Office of Nuclear Reactor Regulation Document Control Desk |
ML023370133 | 29 November 2002 | Safety Evaluation for Amendment Nos. 207 and 212, Increase the Licensed Reactor Core Power Level | NRC/NRR/DLPM/LPD3 Spaulding D | Nuclear Management Co Cayia F |
ML21253A167 | 10 September 2021 | Notification of NRC Design Bases Assurance Inspection (Programs) and Initial Request for Information Inspection Report 05000266/2022010 05000301/2022010 | NRC/RGN-III/DRS/EB2 Benny Jose | Point Beach Strope M |