Forwards SER Re 960209,0717 & 0827 Ltrs Addressing GL 95-07, Pressure Locking & Thermal Binding of Safety-Related Power-Operated Relief Valves, for Point Beach Nuclear Plant Units 1 & 2.Response Adequately Addressed Requested Action
ML20198L104
Person / Time
Site: Point Beach  NextEra Energy icon.png
Issue date: 01/08/1998
From: Gundrum L
NRC (Affiliation Not Assigned)
To: Grigg R
WISCONSIN ELECTRIC POWER CO.
Shared Package
ML20198L108 List:
References
GL-95-07, GL-95-7, TAC-M93505, TAC-M93506, NUDOCS 9801150170
Download: ML20198L104 (2)


Text

_ _.. _

January 8, 1998 Mr. Richard R. Grigg Chief Nuclear Officer Wisconsin Electric Power Company 231 West Michigan Street, Room P379 Mil *sukee, WI 53201

SUBJECT:

POINT BEACH NUCLEAR PLANT, UNIT NOS.1 AND 2 ISSUANCE OF SAFETY EVALUATIOr4 RE: GENERIC LETTER 95-07 PRESSURE LOCKING AND THERMAL BINDING OF SAFETY RELATED POWER-OPERATED RELIEF VALVES (TAC NOS. M93505 AND M93506)

Dear Mr. Grigg:

On August 17,1995, the NRC issued Generic Letter (GL) 95-07, " Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves," to request that licensees take actions to ensure that safety related power-operated gate valves that are susceptible to pressure locking or thermal binding are capable of performing their safety functions.

By letter dated February 9.1996, Wisconsin Electric Power Company (WE) submitted its 180-day response to GL 95-07 for the Point Beach Nuclear Plant. The NRC staff reviewed WE's

- February 9,1996, submittal, and requested additionalinformation in letters dated June 11,1996 and July 10,1997. By letters dated July 17,1996, and August 27,1997, WE provided additional information in response to the NRC staffs requests.

The NRC staff has reviewed WE's submittals of February 9 and July 17,1996, and August 27, t

1997. The staff finds that WE has adequately addressed the requested actions of GL 95-07, as discussed in the enclosed safety evaluation.

Sincerely, Original signed by:

Linda L. Gundrum, Project Manager Project Directorate lil 1 Division of Reactor Projects - Ill/lV Office of Nuclear Reactor Regulation Docket Nos. 50 266 and 50-301

Enclosure:

Safety Evaluation h ily g yg cc w/ encl: See next page DISTRIBMIlQN:

y,A f

Docket File PUBLIC PDill-1 Reading T)%

E. Adensam C, Jamerson L. F ndrum OGC S Tingen ACRS g

R. Eaton SEDB (TLH3)

~ J. McCormick-Barger, Rlli i

DOCUMENT NAME: G:\\WPDOCS\\PTBEACH\\PTB93505.SER v.

wm,.

n on.c mm.w. c.em

,ma.mmm.<wem r.em ma mwe= v.

aw OFFICE PM:PD31 lE LA:PD31 E' C:EMEB \\tl E D:PD31 NAME LGundrum: JUPB CJamerson & RWessmantY CCarpenter$

DATE 12/31/97 i / ff /98

-A 1/07/98 1/db/98 OFFICIAf. RECORD COPY 9001150170 900100 DR ADOCK 05000266 l.i l.l lI l.ll.l l.ll.ll.l p

m

i 0

Mr. Richerd R. Grigg Point Beach Nuclear Plant Wisconsin Electric Power Company Unit Nos.1 and 2 i

cc:

. Emest L. Blake, Jr.

Shaw, Pittman, Potts & Trowbridge 2300 N Street, N.W.

Washington, DC 20037 l

Mr. Scott A. Patuiski Vice Proskient Point Beach Nuclear Plant i

Wisconsin Electric Power Company 6610 Nuclear Road Two Rivers, Wisconsin 54241 Mr. Ken Duveneck i

f Town Chairman Town of Two Creeks 13017 State Highway 42 Mishicot, Wisconsin 54228

' Chairman Public Service Commission of Wisconsin P.O. Box 7854 Madison, %consin 53707-7854 Regional Administrator, Region ll!

U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, Illinois 80532-4351 Resident inspector's Office U.S. Nuclear Regulatory Commission 6612 Nuclear Road Two Rivers, Wisconsin 54241 Ms. Sarah Jenkins Electric Division Public Service Commission of Wisconsin P,0. Box 7854

- Madison. Wisconsin 53707 7854 March 1M7 7

a

+

emp-