 Issue dateTitleFromTo
NRC Generic Letter 1988-0622 March 1988NRC Generic Letter 1988-006: Removal of Organization Charts from Technical Specification Administrative Control RequirementsMiraglia F
Office of Nuclear Reactor Regulation
NRC Generic Letter 1989-043 April 1989NRC Generic Letter 1989-004: Guidance on Developing Acceptable Inservice Testing ProgramsVarga S
Office of Nuclear Reactor Regulation
ML18094A53519 June 1989LER 89-019-00:on 890520,both Loops of RHR Sys Were Declared Inoperable Due to Gas Binding of RHR Pumps.Caused by Personnel Error.Use of Test Procedure Discontinued Until Completion of Review.Procedure RevisedPSEG
Pollack M
ML18094A52820 June 1989LER 89-019-00:on 890520,both Loops of RHR Sys Declared Inoperable Due to Gas Binding of Both RHR Pumps.Caused by Personnel Error.Control Room Panel Mods Will Be Completed During Next Refueling outage.W/890620 LtrPSEG
Miller L
Pollack M
Office of Information Resources Management
ML18094A7493 October 1989Forwards Response to Generic Ltr 89-04 & Rev 2 to Inservice Testing Program for Pumps & Valves for 2nd 10-yr Insp Interval.PSEG
Crimmins T
Office of Information Resources Management
ML18094A7533 October 1989Rev 2 to Inservice Testing Program for Pumps & Valves for 2nd 10-yr Insp Interval.PSEG
ML18094B21421 December 1989Forwards Revised Attachment 1 to Util 891003 Response to Generic Ltr 89-04.Rev Changes Date Ref in Page 2,Position 5 from 891231 to 900115PSEG
Labruna S
Office of Information Resources Management
ML18094B24911 January 1990Forwards Rev to Attachment 1 of 891221 Revised Response to Generic Ltr 89-04 & Requests That 900115 Date Re Procedural Revs Be Extended to 900215 Due to Transfer of Inservice Insp Program & Upcoming NRC Insp on Stated ProceduresPSEG
Labruna S
Office of Information Resources Management
ML18094B32028 February 1990Responds to NRC 900119 Request for Addl Info Re Generic Ltr 89-04, Inservice Insp Program. Encl Contains List of Inservice Testing Program Relief Requests Not Previously Approved & Not in Conformance W/Generic Ltr 89-04PSEG
Miltenberger S
Office of Information Resources Management
ML18095A44023 August 1990LER 90-023-00:on 900725,discovered That Surveillance of Svc Water Sys Check Valves Not Completed Per Inservice Testing Program Manual Requirements.Caused by Inadequate Administrative Controls.Program modified.W/900823 LtrPSEG
Miller L
Pollack M
Office of Information Resources Management
ML18095A80514 March 1991Forwards Rev to Inservice Testing Program & Relief Requests Re Qualifications of Test Supervisors,Auxiliary Feedwater Pumps 11,12 & 13 & Boric Acid Transfer Pumps 11 & 12PSEG
Labruna S
Office of Information Resources Management
ML18095A93616 May 1991Forwards Addl Info Re Inservice Testing Program for Plant Per Generic Ltr 89-04PSEG
Labruna S
Office of Information Resources Management
ML0311405497 November 1991Withdrawn NRC Generic Letter 1991-018: Information to Licensees Regarding Two NRC Inspection Manual Sections on Resolution of Degraded and Nonconforming Conditions and on OperabilityPartlow J
Office of Nuclear Reactor Regulation
ML17349A92731 August 1992Technical Evaluation Rept,Pump & Valve Insevice Testing Program,Salem Generating Station,Units 1 & 2.INC.
EG&G IDAHO
IDAHO NATIONAL ENGINEERING & ENVIRONMENTAL LABORATORY
Yost M
Ransom C
Hartley R
NRC
Information Notice 1993-13, Undetected Modification of Flow Characteristics in High Pressure Safety Injection System16 February 1993Undetected Modification of Flow Characteristics in High Pressure Safety Injection SystemGrimes B
Office of Nuclear Reactor Regulation
ML18100A66212 October 1993Submits Suppl Info Requested in Response to Anomalies Identified in Technical Evaluation Rept Encl to Se,Per GL 89-04.Attachment 1 to Ltr Contains Brief Description of Anomaly & Response to AnomalyPSEG
Hagan J
Office of Information Resources Management
ML18101A49716 January 1995Responds to NRC 941130 Ltr Re Violations Noted in Insp Repts 50-272/94-21 & 50-311/94-21.Corrective Actions:Util Developed Relief Request for SJ3 Valve Open Exercise Test to Be Submitted to NRCPSEG
Hagan J
Office of Information Resources Management
ML18101B10414 November 1995Notifies That Listed Pse&G Commitments to GL 89-04 Not Yet Properly Completed.Pse&G Continuing to Review Plant IST Program & IST Program ImplementationEric Simpson
PSEG
Office of Information Resources Management
NRC Generic Letter 1996-0518 September 1996NRC Generic Letter 1996-005: Periodic Verification of Design-Basis Capability of Safety-Related Motor-Operated ValvesMartin T
Office of Nuclear Reactor Regulation
ML18102A53830 October 1996LER 96-026-00:on 961002,inadequate Testing of RHR Hot Leg Flow Path Discovered.Caused by Inadequate IST Program & Lack of Program Maint.Completed Procedure Revs to Ensure Adequate IST Program Maint & ImplementationPSEG
Bernard Thomas
ML18102A70826 December 1996Forwards Proposed Rev to Inservice Testing Program,Including Relief Requests for V-24 & V-25 for Check Valves SJ55 & SJ56PSEG
Storz L
Office of Information Resources Management
ML18102B5167 August 1997LER 97-009-00:on 970711,failure to Stroke Pump Discharge Valves for Potential Pressure Locking Concern Was Noted. Caused by Personnel Error.Revised Procedures to Address Addl Instances of CS Pump operation.W/970811 LtrMel Gray
PSEG
Garchow D
Office of Information Resources Management
ML18102B6681 October 1997Rev 8 to Inservice Testing Manual for Pumps & Valves Program.PSEG
Lake L
Binz R
Neyhard J
ML18106A42027 March 1998Provides Response to NRC 980127 Ltr Requesting Util Review Concern Re Item in TP-6,Section II.4,as It Applies to ASME Code Re Inservice Testing Program.Util Will Clarify Statement in TP-6 Re Testing of Check ValvesEric Simpson
PSEG
Office of Information Resources Management
ML20211Q87727 August 1999Rev 0 to Inservice Testing Manual for Pumps & Valves ProgramPSEG
Rich Smith
Binz R
Treston W
ML0333709852 January 2004Relief Request Review, Evaluation of Relief Requests S2-RR-03-V01 and S2-RR-03-V02Darrell Roberts
NRC/NRR/DLPM/LPD1
PSEG
Richard Anderson
LR-N04-0299, Inservice Inspection Program Relief Requests S1-RR-04-V01 and V029 July 2004Inservice Inspection Program Relief Requests S1-RR-04-V01 and V02PSEG
Mannon S
Office of Nuclear Reactor Regulation
Document Control Desk
LR-N05-0424, Attachment 1, Calculation S-1-SJ-MDC-1539, Revision 2, Accumulator Pressure Decay Time During Discharge Test.12 August 2005Attachment 1, Calculation S-1-SJ-MDC-1539, Revision 2, Accumulator Pressure Decay Time During Discharge Test.PSEG
Jerome Murphy
Chandra V
Duffy J
Office of Nuclear Reactor Regulation
Document Control Desk
ML05258026630 September 2005Evaluation of Relief Requests S1-RR-04-V01 and S1-RR-04-V02 Related to the Third 10-Year Interval Inservice Testing ProgramStewart Bailey
NRC/NRR/DLPM/LPD1
PSEG
Levis W
ML08255021810 October 2008Safety Evaluation of Relief Requests for the Third 10-Year Interval of the Inservice Testing Program for Salem Nuclear Generating Station, Unit Nos. 1 and 2Chernoff H
Plant Licensing Branch I
PSEG
Levis W
ML0908500662 April 2009Evaluation of Relief Request V-07Chernoff H
Plant Licensing Branch I
PSEG
Joyce T
ML09203046411 August 2009Safety Evaluation of Relief Requests for the Fourth 10-Year Interval of the Inservice Testing Program for Salem Nuclear Generating Station, Unit 1 & 2 (TAC ME0322, ME0323, ME0324, ME0325, ME0326, ME0327, ME0328, ME0329, ME0330, ME0331, ME03Chernoff H
Plant Licensing Branch I
PSEG
Joyce T
LR-N10-0238, Inservice Testing Manual for Pumps and Valves31 August 2009Inservice Testing Manual for Pumps and ValvesPSEG
Kittle W
Office of Nuclear Reactor Regulation
ML12185A16211 July 2012Safety Evaluation of Relief Request Regarding Inservice Pump Testing - Salem Nuclear Generating Station, Unit Nos. 1 and 2Meena Khanna
Plant Licensing Branch I
PSEG
Joyce T