Semantic search
Jump to navigation
Jump to search
Issue date | Title | From | To | |
---|---|---|---|---|
NRC Generic Letter 1988-06 | 22 March 1988 | NRC Generic Letter 1988-006: Removal of Organization Charts from Technical Specification Administrative Control Requirements | Miraglia F Office of Nuclear Reactor Regulation | |
NRC Generic Letter 1989-04 | 3 April 1989 | NRC Generic Letter 1989-004: Guidance on Developing Acceptable Inservice Testing Programs | Varga S Office of Nuclear Reactor Regulation | |
ML18094A535 | 19 June 1989 | LER 89-019-00:on 890520,both Loops of RHR Sys Were Declared Inoperable Due to Gas Binding of RHR Pumps.Caused by Personnel Error.Use of Test Procedure Discontinued Until Completion of Review.Procedure Revised | PSEG Pollack M | |
ML18094A528 | 20 June 1989 | LER 89-019-00:on 890520,both Loops of RHR Sys Declared Inoperable Due to Gas Binding of Both RHR Pumps.Caused by Personnel Error.Control Room Panel Mods Will Be Completed During Next Refueling outage.W/890620 Ltr | PSEG Miller L Pollack M | Office of Information Resources Management |
ML18094A749 | 3 October 1989 | Forwards Response to Generic Ltr 89-04 & Rev 2 to Inservice Testing Program for Pumps & Valves for 2nd 10-yr Insp Interval. | PSEG Crimmins T | Office of Information Resources Management |
ML18094A753 | 3 October 1989 | Rev 2 to Inservice Testing Program for Pumps & Valves for 2nd 10-yr Insp Interval. | PSEG | |
ML18094B214 | 21 December 1989 | Forwards Revised Attachment 1 to Util 891003 Response to Generic Ltr 89-04.Rev Changes Date Ref in Page 2,Position 5 from 891231 to 900115 | PSEG Labruna S | Office of Information Resources Management |
ML18094B249 | 11 January 1990 | Forwards Rev to Attachment 1 of 891221 Revised Response to Generic Ltr 89-04 & Requests That 900115 Date Re Procedural Revs Be Extended to 900215 Due to Transfer of Inservice Insp Program & Upcoming NRC Insp on Stated Procedures | PSEG Labruna S | Office of Information Resources Management |
ML18094B320 | 28 February 1990 | Responds to NRC 900119 Request for Addl Info Re Generic Ltr 89-04, Inservice Insp Program. Encl Contains List of Inservice Testing Program Relief Requests Not Previously Approved & Not in Conformance W/Generic Ltr 89-04 | PSEG Miltenberger S | Office of Information Resources Management |
ML18095A440 | 23 August 1990 | LER 90-023-00:on 900725,discovered That Surveillance of Svc Water Sys Check Valves Not Completed Per Inservice Testing Program Manual Requirements.Caused by Inadequate Administrative Controls.Program modified.W/900823 Ltr | PSEG Miller L Pollack M | Office of Information Resources Management |
ML18095A805 | 14 March 1991 | Forwards Rev to Inservice Testing Program & Relief Requests Re Qualifications of Test Supervisors,Auxiliary Feedwater Pumps 11,12 & 13 & Boric Acid Transfer Pumps 11 & 12 | PSEG Labruna S | Office of Information Resources Management |
ML18095A936 | 16 May 1991 | Forwards Addl Info Re Inservice Testing Program for Plant Per Generic Ltr 89-04 | PSEG Labruna S | Office of Information Resources Management |
ML031140549 | 7 November 1991 | Withdrawn NRC Generic Letter 1991-018: Information to Licensees Regarding Two NRC Inspection Manual Sections on Resolution of Degraded and Nonconforming Conditions and on Operability | Partlow J Office of Nuclear Reactor Regulation | |
ML17349A927 | 31 August 1992 | Technical Evaluation Rept,Pump & Valve Insevice Testing Program,Salem Generating Station,Units 1 & 2. | INC. EG&G IDAHO IDAHO NATIONAL ENGINEERING & ENVIRONMENTAL LABORATORY Yost M Ransom C Hartley R | NRC |
Information Notice 1993-13, Undetected Modification of Flow Characteristics in High Pressure Safety Injection System | 16 February 1993 | Undetected Modification of Flow Characteristics in High Pressure Safety Injection System | Grimes B Office of Nuclear Reactor Regulation | |
ML18100A662 | 12 October 1993 | Submits Suppl Info Requested in Response to Anomalies Identified in Technical Evaluation Rept Encl to Se,Per GL 89-04.Attachment 1 to Ltr Contains Brief Description of Anomaly & Response to Anomaly | PSEG Hagan J | Office of Information Resources Management |
ML18101A497 | 16 January 1995 | Responds to NRC 941130 Ltr Re Violations Noted in Insp Repts 50-272/94-21 & 50-311/94-21.Corrective Actions:Util Developed Relief Request for SJ3 Valve Open Exercise Test to Be Submitted to NRC | PSEG Hagan J | Office of Information Resources Management |
ML18101B104 | 14 November 1995 | Notifies That Listed Pse&G Commitments to GL 89-04 Not Yet Properly Completed.Pse&G Continuing to Review Plant IST Program & IST Program Implementation | Eric Simpson PSEG | Office of Information Resources Management |
NRC Generic Letter 1996-05 | 18 September 1996 | NRC Generic Letter 1996-005: Periodic Verification of Design-Basis Capability of Safety-Related Motor-Operated Valves | Martin T Office of Nuclear Reactor Regulation | |
ML18102A538 | 30 October 1996 | LER 96-026-00:on 961002,inadequate Testing of RHR Hot Leg Flow Path Discovered.Caused by Inadequate IST Program & Lack of Program Maint.Completed Procedure Revs to Ensure Adequate IST Program Maint & Implementation | PSEG Bernard Thomas | |
ML18102A708 | 26 December 1996 | Forwards Proposed Rev to Inservice Testing Program,Including Relief Requests for V-24 & V-25 for Check Valves SJ55 & SJ56 | PSEG Storz L | Office of Information Resources Management |
ML18102B516 | 7 August 1997 | LER 97-009-00:on 970711,failure to Stroke Pump Discharge Valves for Potential Pressure Locking Concern Was Noted. Caused by Personnel Error.Revised Procedures to Address Addl Instances of CS Pump operation.W/970811 Ltr | Mel Gray PSEG Garchow D | Office of Information Resources Management |
ML18102B668 | 1 October 1997 | Rev 8 to Inservice Testing Manual for Pumps & Valves Program. | PSEG Lake L Binz R Neyhard J | |
ML18106A420 | 27 March 1998 | Provides Response to NRC 980127 Ltr Requesting Util Review Concern Re Item in TP-6,Section II.4,as It Applies to ASME Code Re Inservice Testing Program.Util Will Clarify Statement in TP-6 Re Testing of Check Valves | Eric Simpson PSEG | Office of Information Resources Management |
ML20211Q877 | 27 August 1999 | Rev 0 to Inservice Testing Manual for Pumps & Valves Program | PSEG Rich Smith Binz R Treston W | |
ML033370985 | 2 January 2004 | Relief Request Review, Evaluation of Relief Requests S2-RR-03-V01 and S2-RR-03-V02 | Darrell Roberts NRC/NRR/DLPM/LPD1 | PSEG Richard Anderson |
LR-N04-0299, Inservice Inspection Program Relief Requests S1-RR-04-V01 and V02 | 9 July 2004 | Inservice Inspection Program Relief Requests S1-RR-04-V01 and V02 | PSEG Mannon S | Office of Nuclear Reactor Regulation Document Control Desk |
LR-N05-0424, Attachment 1, Calculation S-1-SJ-MDC-1539, Revision 2, Accumulator Pressure Decay Time During Discharge Test. | 12 August 2005 | Attachment 1, Calculation S-1-SJ-MDC-1539, Revision 2, Accumulator Pressure Decay Time During Discharge Test. | PSEG Jerome Murphy Chandra V Duffy J | Office of Nuclear Reactor Regulation Document Control Desk |
ML052580266 | 30 September 2005 | Evaluation of Relief Requests S1-RR-04-V01 and S1-RR-04-V02 Related to the Third 10-Year Interval Inservice Testing Program | Stewart Bailey NRC/NRR/DLPM/LPD1 | PSEG Levis W |
ML082550218 | 10 October 2008 | Safety Evaluation of Relief Requests for the Third 10-Year Interval of the Inservice Testing Program for Salem Nuclear Generating Station, Unit Nos. 1 and 2 | Chernoff H Plant Licensing Branch I | PSEG Levis W |
ML090850066 | 2 April 2009 | Evaluation of Relief Request V-07 | Chernoff H Plant Licensing Branch I | PSEG Joyce T |
ML092030464 | 11 August 2009 | Safety Evaluation of Relief Requests for the Fourth 10-Year Interval of the Inservice Testing Program for Salem Nuclear Generating Station, Unit 1 & 2 (TAC ME0322, ME0323, ME0324, ME0325, ME0326, ME0327, ME0328, ME0329, ME0330, ME0331, ME03 | Chernoff H Plant Licensing Branch I | PSEG Joyce T |
LR-N10-0238, Inservice Testing Manual for Pumps and Valves | 31 August 2009 | Inservice Testing Manual for Pumps and Valves | PSEG Kittle W | Office of Nuclear Reactor Regulation |
ML12185A162 | 11 July 2012 | Safety Evaluation of Relief Request Regarding Inservice Pump Testing - Salem Nuclear Generating Station, Unit Nos. 1 and 2 | Meena Khanna Plant Licensing Branch I | PSEG Joyce T |