Issue date | Title | From | To | |
---|---|---|---|---|
NRC Generic Letter 1988-07 | 7 April 1988 | NRC Generic Letter 1988-007: Modified Enforcement Policy Relating to 10 CFR 50.49 Environmental Qualification of Electrical Equipment Important to Safety for Nuclear Power Plants. | Miraglia F Office of Nuclear Reactor Regulation | |
NRC Generic Letter 1988-12, Removal of Fire Protection Requirements from Technical Specification | 2 August 1988 | NRC Generic Letter 1988-012: Removal of Fire Protection Requirements from Technical Specifications | Miraglia F Office of Nuclear Reactor Regulation | |
ML20204J422 | 17 October 1988 | EN-88-085:on 881020,proposed Imposition of Civil Penalty in Amount of $150,000 Will Be Issued to Licensee.Action Based on Violation of Equipment Qualification Requirements of 10CFR50.49 | NRC OFFICE OF ENFORCEMENT (OE) Lieberman J Luehman J | |
ML20205A720 | 20 October 1988 | Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $150,000.Noncompliance Noted:Amp nylon- Insulated Butt Splices Used in Numerous Items of Electrical Equipment Important to Safety Not Properly Qualified | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) Davis A | |
ML20205A705 | 20 October 1988 | Discusses Insp on 861209 & 870608-0728 & Forwards Notice of Violation & Proposed Imposition of Civil Penalty | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) Davis A | Exelon Oconnor J |
ML20195G796 | 21 November 1988 | Responds to NRC Re Violations Noted in Insp Repts 50-254/86-21,50-254/87-11,50-265/86-21 & 50-265/87-11 Re Use of Unqualified AMP nylon-insulated Butt Splices in GE Foi Containment Penetration Enclosures at Facility | SIDLEY & AUSTIN Fieldman J | NRC OFFICE OF ENFORCEMENT (OE) Lieberman J |
ML20246A009 | 3 May 1989 | Order Imposing Civil Monetary Penalty in Amount of $75,000, Based on Util Lack of Demonstration That AMP Splices Environmentally Qualified | NRC OFFICE OF THE EXECUTIVE DIRECTOR FOR OPERATIONS (EDO) Thompson H | Exelon |
ML17285A808 | 18 October 1989 | Responds to Request for Info on Environ Qualification of Taped Electrical Splices.Scotch Tapes Allowed by Electrical Test Guide Included Scotch 33,23 & 70 | Energy Northwest Bouchey G | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V) Zimmerman R Office of Information Resources Management |
ML031140549 | 7 November 1991 | Withdrawn NRC Generic Letter 1991-018: Information to Licensees Regarding Two NRC Inspection Manual Sections on Resolution of Degraded and Nonconforming Conditions and on Operability | Partlow J Office of Nuclear Reactor Regulation | |
Information Notice 1992-81, Potential Deficiency of Electrical Cables with Bonded Hypalon Jackets | 11 December 1992 | Potential Deficiency of Electrical Cables with Bonded Hypalon Jackets | Grimes B Office of Nuclear Reactor Regulation | |
Information Notice 1993-33, Potential Deficiency of Certain Class IE Instrumental and Control Cables | 28 April 1993 | Potential Deficiency of Certain Class IE Instrumental and Control Cables | Grimes B Office of Nuclear Reactor Regulation | |
Information Notice 1993-33, Potential Deficiency of Certain Class Ie Instrumental and Control Cables | 28 April 1993 | Potential Deficiency of Certain Class Ie Instrumental and Control Cables | Grimes B K Office of Nuclear Reactor Regulation |