Issue date | Title | Topic | |
---|---|---|---|
ML14211A071 | 13 August 2014 | Relief from Examination Coverage Requirements of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section XI, for the Fourth 10-Year Inservice Inspection Program Interval | Non-Destructive Examination VT-2 Incorporated by reference |
L-MT-13-089, 10 CFR 50.55a Request No. 21: Relief from Impractical Examination Coverage Requirements Pursuant to 10 CFR 50.55a(g)(5)(iii) for the Fourth Ten-Year Lnservice Inspection Interval | 28 August 2013 | 10 CFR 50.55a Request No. 21: Relief from Impractical Examination Coverage Requirements Pursuant to 10 CFR 50.55a(g)(5)(iii) for the Fourth Ten-Year Lnservice Inspection Interval | Nondestructive Examination VT-2 Aging Management Pressure Boundary Leakage |
ML13099A275 | 9 April 2013 | NRR E-mail Capture - Monticello Nuclear Generating Plant - Request for Additional Information Fifth 10-Year Inservice Inspection Program Plan Review | |
ML102210517 | 9 August 2010 | Revised Draft RAI on Relief Request 19 | |
ML102080492 | 27 July 2010 | Draft RAI on Relief Request No. 19 Re. Impractical Exam Coverage | |
L-MT-10-034, Relief Request from Certain Examination Coverage Requirements Imposed by the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section Xl, Rules for Inservice Inspection of Nuclear Power Plant Components. | 6 May 2010 | Relief Request from Certain Examination Coverage Requirements Imposed by the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section Xl, Rules for Inservice Inspection of Nuclear Power Plant Components. | Nondestructive Examination VT-2 |
L-MT-09-078, Submittal of Cycle No. 24 Inservice Inspection Summary Report for Inservice Inspection and ASME Section Xl Repairs and Replacements | 7 August 2009 | Submittal of Cycle No. 24 Inservice Inspection Summary Report for Inservice Inspection and ASME Section Xl Repairs and Replacements | Stroke time Weld Overlay Hydrostatic Anchor Darling Nondestructive Examination VT-2 EVT-1 Liquid penetrant Pressure Boundary Leakage |
ML081050678 | 19 May 2008 | Granting of Relief Regarding Limited Ultrasonic Examination Coverage of Five Welds | Nondestructive Examination VT-2 Incorporated by reference |
L-MT-07-071, CFR 50.55a Request No. 15: Relief from Impractical Examination Coverage Requirements Pursuant to 10 CFR 50.55a(g)(5)(iii) for the Fourth Ten-Year Inservice Inspection Interval | 26 September 2007 | CFR 50.55a Request No. 15: Relief from Impractical Examination Coverage Requirements Pursuant to 10 CFR 50.55a(g)(5)(iii) for the Fourth Ten-Year Inservice Inspection Interval | Nondestructive Examination VT-2 |
L-MT-07-058, Cycle No. 23 Lnservice Inspection Summary Report for Lnservice Inspection and ASME Section XI Repairs and Replacements | 27 July 2007 | Cycle No. 23 Lnservice Inspection Summary Report for Lnservice Inspection and ASME Section XI Repairs and Replacements | Stroke time Hydrostatic Coatings Nondestructive Examination VT-2 Scram Discharge Volume Code Reconciliation EVT-1 Liquid penetrant Scaffolding |
ML061780172 | 18 July 2006 | Fourth 10-Year Interval Inservice Inspection Program Plan, Relief Request No. 13 | Nondestructive Examination VT-2 Incorporated by reference |
L-MT-05-088, 10 CFR 50.55a Request No. 13: Relief from Impractical Examination Coverage Requirements Pursuant to 10 CFR 50.55a(g)(5)(iii) for the Fourth Ten-Year Inservice Inspection Interval | 27 September 2005 | 10 CFR 50.55a Request No. 13: Relief from Impractical Examination Coverage Requirements Pursuant to 10 CFR 50.55a(g)(5)(iii) for the Fourth Ten-Year Inservice Inspection Interval | Nondestructive Examination VT-2 |
L-MT-05-078, Summary Report for Inservice Inspections and ASME Section XI Repairs and Replacements | 12 July 2005 | Summary Report for Inservice Inspections and ASME Section XI Repairs and Replacements | Stroke time Hydrostatic Nondestructive Examination Squib VT-2 EVT-1 Liquid penetrant Pressure Boundary Leakage |
L-MT-04-050, Fourth Interval Inservice Inspection Examination Plan, Revision 2 | 16 September 2004 | Fourth Interval Inservice Inspection Examination Plan, Revision 2 | Hydrostatic Probabilistic Risk Assessment Nondestructive Examination VT-2 Large early release frequency Scaffolding |
ML031400119 | 19 May 2003 | Relief, Third 10-Year Interval Inservice Inspection Relief Request No 16, Parts a, B, and C | VT-2 Incorporated by reference |
L-MT-03-004, Change to Inservice Program Plan & Inservice Inspection Examination Plan 10-Year Intervals | 23 January 2003 | Change to Inservice Program Plan & Inservice Inspection Examination Plan 10-Year Intervals | Hydrostatic Scaffolding |
ML021680035 | 30 May 2002 | Request for Review and Approval of Relief Request Nos. 15 and 16 for Monticello 3rd 10-Year Interval Inservice Inspection Examination Plan | Nondestructive Examination VT-2 |
ML20210Q052 | 4 August 1999 | Safety Evaluation Approving Relief Request 10 to License DPR-22 Per 10CFR50.55a(g)(6)(i).Inservice Exam for Relief Request 10,Parts A,B,C,D & E Impractical & Reasonable Assurance of Structural Integrity Provided | Boric Acid Hydrostatic Incorporated by reference |
Information Notice 1998-42, Implementation of 10 CFR 55.55a(g) Inservice Inspection Requirements | 1 December 1998 | Implementation of 10 CFR 55.55a(g) Inservice Inspection Requirements | |
ML20236U699 | 24 July 1998 | Requests Review & Approval of ISI Relief Request 10 to Third 10-yr Plan.Ltr Contains No New NRC Commitments | Hydrostatic |
ML20236W504 | 21 July 1998 | ISI Exam Summary Rept - Refueling Outage 19 | Hydrostatic Nondestructive Examination VT-2 |
ML20198P958 | 13 January 1998 | Forwards Operability Determination for ISI Components That Were Not Fully Examined in Second ten-year ISI Interval as Requested by Ts,For NRC Info | Boric Acid Non-Destructive Examination Hydrostatic Dissimilar Metal Weld |