Issue date | Title | Topic | |
---|---|---|---|
ML20126F118 | 5 September 1975 | AO 50-213/75-3:on 750904,greater than 2 Delta Dissolved Oxygen Alarm Received.Caused by Oxygen Scavanging from Canal Water on Start of Dredging Operation.Backup Sys Started. Monitoring & Grab Sample Results Encl | Grab sample |
ML20126F179 | 6 May 1974 | AO 74-08:emergency Diesel Generator 2B Caught Fire Before Completion of Monthly Load Test.Caused by Overheating of Field Excitation Transformer & Subsequent Burn in Winding. Transformer Removed Pending Receipt of Replacement | |
ML20126F183 | 5 April 1974 | AO 74-06:containment Penetration P-60 Failed to Meet Acceptable Leak Rate During Routine Surveillance Test. Cause Under Investigation |