ML20126F183
| ML20126F183 | |
| Person / Time | |
|---|---|
| Site: | Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png |
| Issue date: | 04/05/1974 |
| From: | Hartley F CONNECTICUT YANKEE ATOMIC POWER CO. |
| To: | James O'Reilly NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| References | |
| AO-74-06, AO-74-6, CYH-2628, NUDOCS 8103090798 | |
| Download: ML20126F183 (1) | |
Text
-... - -.
N D' Agulatorf t
4 CONNECTICUT YANKEE AT O M IC POWER COMPANY
. -[
~I HADDAM NECK PLANT.
f
' )Q/.'/
RR = 1, DOX 127E, EAST H AMPTON, CONN. 06424 i
3 April 5,1974 CYH-2628 DOCKET 50-213 -._,,,
{ V 'Q(/7-%
o ',
i 14r. James P. O'Reilly, Director p,' > ~
g Region 1
.g' / p;t W.u ' @M "
,-E, Directorate of Regulatory Operations U. S. Atomic Energy Commission w
ApR1013 631 Park Avenue
.c
.., pmt C/:
King of Prussia, Pennsylvania
.'.:... ty' wta tL' j;
p,
- g, Dear lir. O'Reilly; 4
w -)
r As defined by Technical Specifications for Connecticut Yankee Atomic Power Station, Section 5.3, the following information involving
[
the failure of a containment penetration to meet an acceptable leak rate during a routine periodic surveillance leak rate test is reported as Abnormal Occurrence 74-6.
~
Following a periodic leak rate test of containment penetration P-60 (component cooling water supply to the neutron shield tank cooler) calculations indicated a leak rate in excess of that allowed.
This test involves the measurement of any water leaking back through a check valve installed in the nornal cooling water supply line to l
the neutron shield tank while pressurized to containment design pressure of 40 psig.
An investigation into the cause of the excess leakage through J
the check valve is being conducted and a written report will be submitted within ten days.
Very truly yours, J
u j, a.