SOUTH TEXAS PROJECT ELECTP!C GENERATING STATION UNIT 1 MONTHLY OPERATING REPORT HOUSTON LIGHTING AND POWER CO.

NRC DOCKET NO. 50-498 LICENSE NO. NPF-71 Prepared by: _ D 2 /[r ['

Lead P6rfordance Technician Dat.4 Reviewed by: -

01 !or d2 Performance Technician Supervisor Date

.- j -- -

Al1ldl Reviewed By: '_ .d L, fA / .

Ple(t Engineering Manager Date Approved By: bzthk A Ee Plant Manager \ bate

, c-dt I

8802180200 880131 PDR ADOCN 05000498 R DCD

\

s OPERATING DATA REPORT DOCKET NO. 50-498 UNIT 1 DATE 02/01/88 COMPLETED BY J. J. Nesrsta TELEPHONE 512-972-7827 OPERATIEG STATUS

1. REPORTING PERIOD: 01/01-01/31 GROSS HOURS IN REPORTING PERIOD: 744
2. CURRENTLY AUTHORIZED POWER LEVEL (NWt): 190 MAX. DEPEND. CAPACITY (MWe-Net): 0 DESIGN ELECTRICAL RATING (NWe-Net):1250.6
3. POWER LEVEL TO WHICH RESTRICTED (IF ANY)(NWe-Net): 5% _
4. REASONS FOR RESTRICTION (IF ANY): Condition of initial low-power license NPF-71.

THIS MOETH YR TO DATE CUNUIATIVE

5. NUMBER OF HOURS REACTOR WAS CR:'TICAL....... 0 0 0
6. REACTOR RESERVE SHU'"DOWN HOURS . . . . . . . . . . . . . 0 0 0
7. HOURS GENERATOR ON LINE.................... 0 0 0
8. UNIT RESERVE SHUTDOWN HOURS................ 0 0 0
9. GROSS THERMAL ENERGY GENERATED (MWH)....... 0 0 0
10. GROSS ELECTRICAL ENERGY GENERATED.......... 0 0 0
11. NET ELECTRICAL ENERGY GENERATED (MWH)...... O O O
12. REACTOR SERVICE FACTOR..................... N/A N/A N/A
13. REACTOR AVAILABILITY FACTOR. .............. N/A N/A .. N/A
14. UNIT SERVICE FACTOR........................ N/A _N/A N/A
15. UNIT AVAILABILITY FACTOR................... N/A N/A N/A
16. UNIT CAPACITY FACTOR (Using MDC)........... N/A N/A N/A
37. UNIT CAPACITY FACTOR (Using Design MWe).... N/A N/A__ N/A
18. UNIT FORCED OUTAGE RATE...................._El.fL._ N/A N/A _
19. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE AND DURATION OF EACH): N/A
20. IF SHUT DOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP: N/A
21. UNITS IN TEST STATUS (PRIOR TO COMMERCIAL OPERATION): FORECAST ACHIEVED INITIAL CRITICALITY 02/12/88 INITIAL ELECTRICITY 03/03/88 COMMERCIAL OPERATION 05/88 NRC.M.O.R.JAN

I AVERAGE DULY UNIT POWER I2YEL DOCKET NO. 50-498 UNIT 1 DATE 02/01/88 COMPLETED 3Y J.J. Nesrste TELEPHONE 512-972-7827 MONTH Januarv DM AVEEAGE DMLY POWER LEVEL DAY AYERAGE DAILY POWEE LEYEL (MWe-Net) (MWe-Net) 1 0 17 0 2 0 18 0 3 0 19 0 4 0 20 0 5 0 21 0 ,

6 0 22 0 7 0 23 0 8 0 24 0 9 0 25 0 10 0 26 0 11 0 27 0 12 0 28 0 13 0 29 0 14 0 30 0 15 0 31 0 16 0 NRC.M.O.R.JAN

UNIT SHUTDOWES AND POWER REDUCTIONS DOCKET NO. 50-498 UNIT NAME 1 DATE O2/01/88 COMPLETED BY J. J. Nesrsta TELEPHONE 512-972-7827 REPORT MONTH Jam a.II I I I I I I I I I I I I I I I I I I I I I I I No. I Date l Type i Duration i Reason i Method of I Licensee 1 Systgm l Compongnt I Cause & Corrective l I I I I (Hours) l I Shutting i Event I Code i Code i Action to i I I I I I I Down Reactor i Report # I I I Prevent Recurrence l I I I I I I I I I I I i l i i l I i I i I i I I I I I I i I I i i IN/A I N/A I N/A I N/A I N/A I N/A 1 N/A I N/A I N/A I N/A I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I i 1 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I F: Forced Rex son: Method: IEEE 805-1983 S: Scheduled A a.quipment Failure (Explain) 1-Manual B-Naintenance or Test 2-Manual Scram.

C-Refueling 3-Automatic Scram.

5 D-Regulatory Restriction 4-Cont. of Existing IEEE 803A-1983 E-Operator Training & License Examination Outage F-Administrative 5-Reduction G-Operational Error (Explain) 9-Other H-Other (Explain)

NRC.N.O.R.JAN

3 PORV's and Saftey Valves Summary On January 3, 1988, while filling and venting the reactor coolant system, a reactor coolant pump was actuated with the reactor coolant system at less than 350 degrees F in a water solid condition and secondary water temperatures greater than 50 degrees F above RCS cold leg temperatures. This resulted in a pressure spike which prompted the actuation of a pressurizer power-operated relief valve (PORV). This event is described in detail in LER 88-001.

l l

l l

l i

l l

i l

l l

. The Light company PO. Box 1700 liouston. 'lixas 77001 (713) 228 9211 llouston 1.ighting & Power February 10, 1988 ST-HL-AE-2503 File No.- G02 10CFR50.71 U. S. Nuclear Regulatory Cor. mission Attention: Document Control Desk Washington, DC 20555 South Texas Proj ect Electric Generating Station Unit 1 Docket No. STN 50-498 Monthly Operating Report - January 1988 Pursuant to 10CFR50.7)(a) and the South Texas Proj ect Electric Generating Station (STPEGS) Unit 1 Technical Specification 6.9.1.5, the attached Monthly Operating Report f or January 1988 is submitted.

If you should have any questions on this matter, please contact Mr. C.A. Ayale at (512) 972-8628.

y N

. G. E. Vaughn Vice President Nuclear Plant Operations GEV/CAA/krm Attachn.ent: STPEGS Unit 1 Monthly Operating Report - January 1988 NL . NRC . MOR . J AN A 5uliudim <>f flouston Industries incorporated h !

lloust<m Lighting & Power Company ST-HL-AE-2503 File No.: G02 Page 2 cc:

Regional Administrator, Region IV Rufus S. Scott Nuclear Regulatory Commission Associate General Counsel 611 Ryan Plaza Drive, Suite 1000 Houston Lighting & Power Company Arlington, TX 76011 P. O. Box 1700 Houston, TX 77001 N. Prasad Kadambi, Project Manager U. S. Nuclear Regulatory Commission INPO 1 White Flint North Records Center 11555 Rockville Pike 1100 Circle 75 Parkway Rockville, MD 20859 Atlanta, Ga. 30339-3064 Dan R. Carpenter Senior Resident Inspector / Operations e/o U. S. Nuclear Regulatory Commission P. O. Box 910 Bay City, TX 77414 J. R. Ne' n, Esquire Newman & Holtzinger, P.C.

1615 L Street, N.W.

Washington, DC 20036 R. L. Range /R. P. Verret Central Power & Light Company P. O. Box 2121 Corpus Christi, TX 78403 R. John Miner (2 copies)

Chief Operating Officer City of Austin Electric Utility 721 Barton Springs Road Austin, TX 78704 R. J. Costello/M. T. Hardt City Public Service Board P. O. Box 1771 San Antonio, TX 79296 i

i i

Revised 02/03/88 NL.LER. DISTR.1

. . - . . , - , , - .- , - , - . . , -. ,,---.-,-n , . - . .