NRC Generic Letter 82-08, Transmittal of NUREG-0909 Relative to the Ginna Tube Rupture
text
April 15, 1982
TO ALL PRESSURIZED WATER REACTOR PLANT LICENSEES AND APPLICANTS
Gentlemen:
SUBJECT: TRANSMITTAL OF NUREG-0909 RELATIVE TO THE GINNA TUBE RUPTURE (Generic Letter No. 82-08)
On January 25, 1982, the R. E. Ginna Nuclear Power Plant experienced a rupture of a steam generator tube. Shortly after the event, Chairman Palladino directed that a task force be established to gather and report on the factual information surrounding the event.
The task force has now completed its investigation and has documented the factual information and their findings associated with the event (See Enclosed NUREG-0909). You should review the information for applicability to your facility.
In addition, you should ensure that the information in NUREG-0909 is made available to your plant staff as part of your training program under TMI Action Plan Item I.C.5, Feedback of Operating Experience to Plant Staff.
Sincerely,
Darrell G. Eisenhut, Director Division of Licensing Office of Nuclear Reactor Regulation
Enclosure:
8204160155