NRC Generic Letter 80-19, Resolution of Enhanced Fission Gas Release Concern
text
GL80019
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555
March 10, 1980
Docket No. 50-263
Mr. L. O. Mayer, Manager Nuclear Support Services Northern States Power Company 414 Nicollet Mall - 8th Floor Minneapolis, Minnesota 55401
Dear Mr. Mayer:
During the last several years, data have begun to indicate that the fission gas release rate from LWR fuel pellets is increased (enhanced) with burnup. Many of the current fuel performance analyses do not consider the impact of burnup release on safety. By letters dated November 23, 1976, the NRC staff requested all LWR licensees to assess the higher fission gas release for fuel burnups above 20,000 Megawatt-day per metric ton (MWD/T).
Also, by NRC staff letter dated January 18, 1978, all U.S. LWR fuel suppliers were requested to revise their fuel performance analyses to include the enhancement of fission gas release at higher burnups.
All responses to the November 23, 1976 letters have been reviewed. We have concluded that no immediate licensing action is required for operating reactors. This conclusion is valid for typical reported LWR fuel bundle and batch burnups. Any extension of these burnups or other factors which significantly affect fission gas release, LOCA PCT or fuel rod internal pressure is outside the scope of the conclusion.
The effect of enhanced release on BWR ECCS performance has been discussed with General Electric (GE). GE has pointed out that because of operational restrictions and physical limitations, the LOCA analysis is not limiting in high burnup fuel (25,000 MWD/T). High burnup fuel generally cannot achieve linear power densities near the LOCA limit early in cycle. The limiting fuel bundle is usually in its second cycle of reactor operations where burnup levels are below 20,000 MWD/T. Late in a BWR fuel cycle, there is less axial power peaking reducing the feasibility for the fuel bundle power is generally limited by MCPR considerations. Thus, it is unlikely that a high burnup bundle can exceed the ECCS performance criteria in case of a LOCA. The argument is appropriate for Exxon fuel bundle design also based on the review of Exxon analyses for operating BWRs. Therefore, no immediate licensing action is necessary on operating BWRs.
.
Inasmuch as you and/or the staff will be evaluating all future reloads against fuel vendors' revised fuel performance codes which provide for increase in fission gas release at higher burnups, we consider this a satisfactory resolution of this concern. Harold R. Denton, Director Office of Nuclear Reactor Regulation
cc: See next page