NRC Generic Letter 79-60, Discussion of Lessons Learned Short Term Requirements
text
GL79060
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555
November 9, 1979
TO ALL PENDING OPERATING LICENSE APPLICANTS
Gentlemen:
SUBJECT: DISCUSSION OF LESSONS LEARNED SHORT TERM REQUIREMENTS
On September 27, 1979, you received a letter which defined a set of "short term" requirements resulting from the NRC staff investigations of the TMI accident. Since the letter was issued, the staff has further defined these requirements.
Enclosure 1 provides the additional clarifications of the NRC staff requirements as provided to licensees of operating reactors. Enclosure 2 provides a list of modifications to these clarifications to make them applicable to applicants for operating licenses, applicants for construction permits and licensees of plants under construction. It should be noted that the intent of these requirements and the purpose of our letter of September 27, 1979 have not changed.
If you have any questions regarding these actions, please contact the NRC Project Manager for your facility.
Sincerely,
D. R. Vassallo, Acting Director Division of Project Management Office of Nuclear Reactor Regulation
Enclosure:
Discussion of TMI Lessons Learned Short Term Requirements
ccs:
Service List
.
UNDER OL REVIEW
- 1. Farely Alabama Power Company
- 2. Byron/Braidwood Commonwealth Edison
- 3. LaSalle "
- 4. Zion "
- 5. Midland Consumers Power
- 6. Greenwood Detroit Edison
- 7. Catawba Duke Power Company
- 8. McGuire "
- 9. So. Texas Houston Lighting & Power
- 10. Shoreham Long Island Lighting
- 11. Waterford Louisiana Power & Light
- 12. Grand Gulf Mississippi Power & Light
- 13. Ohio Edison Company
- 14. Diablo Canyon Pacific Gas & Electric
- 15. Susquehana Pennsylvania Power & Light
- 16. Salem 2 Public Service Gas & Electric
- 17. Summer So. Carolina Electric & Gas
- 18. San Onofre So. California Edison San Diego Gas & Electric Co.
- 19. Bellefonte Tennessee Valley Authority
- 20. Watts Bar "
- 21. Sequoyah "
- 22. Comanche Peak Texas Utilities Generating
- 23. Toledo Edison
- 24. North Anna 2 Virginia Electric & Power
- 25. WPPSS-2 Washington P. O. S. S.
- 26. Fermi Detroit Edison
- 27. Zimmer Cincinnati Gas & Electric
.
CONSTRUCTION PERMIT with Application for OL
Pressurized Water Reactors
50-275/323
50-311
50-327/328
50-329/330
50-361/362
50-364
50-369/370
50-373/374
50-382
50-390/391
50-395
50-438/439
50-445/446
50-454/455
50-456/457
50-498/499
.
CONSTRUCTION PERMIT with application for OL
Boiling Water Reactors
50-322
50-341
50-358
50-387/388
50-397
50-416/417