NRC Generic Letter 1984-16

From kanterella
Jump to navigation Jump to search
NRC Generic Letter 1984-016: Adequacy of On-Shift Operating Experience for Near Term Operating License Applicants
ML031180041
Person / Time
Site: Beaver Valley, Millstone, Hatch, Monticello, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Mcguire, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Kewaunee, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Oyster Creek, Watts Bar, Hope Creek, Grand Gulf, Cooper, Sequoyah, Byron, Pilgrim, Arkansas Nuclear, Braidwood, Susquehanna, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, Limerick, North Anna, Turkey Point, River Bend, Vermont Yankee, Crystal River, Haddam Neck, Ginna, Diablo Canyon, Callaway, Vogtle, Waterford, Duane Arnold, Farley, Robinson, Clinton, South Texas, San Onofre, Cook, Comanche Peak, Yankee Rowe, Maine Yankee, Quad Cities, Humboldt Bay, La Crosse, Big Rock Point, Rancho Seco, Zion, Midland, Bellefonte, Fort Calhoun, FitzPatrick, McGuire, LaSalle, 05000000, Zimmer, Fort Saint Vrain, Shoreham, Satsop, Trojan, Atlantic Nuclear Power Plant, Skagit, Marble Hill, Crane
Issue date: 06/27/1984
From: Eisenhut D
Office of Nuclear Reactor Regulation
To:
References
NUREG-0737 GL-84-016, NUDOCS 8406270142
Download: ML031180041 (16)


June 27, 1984 TO ALL LICENSEES OF OPERATING REACTORS, APPLICANTS FOR OPERATING

LICENSE, AND HOLDERS OF CONSTRUCTION PERMITS

Gentlemen:

SUBJECT: ADEQUACY OF ON-SHIFT OPERATING EXPERIENCE FOR

NEAR TERM OPERATING LICENSE APPLICANTS

(Generic Letter 84-16)

On June 14, 1984, the Chairman of the U. S. Nuclear Regulatory Commission, N. J. Palladino, sent J. H. Miller, President, Georgia Power Company, a letter in which the Commissioners presented their views on the subject of adequacy of on-shift operating experience for near-term operating license applicants.

This letter is enclosed and is applicable for near-term operating license applicants.

The June 14, 1984 letter accepted, with some clarifications, an Industry Working Group proposal on this subject, presented to the Commission on February 24, 1984.

Commissioners Gilinsky and Asselstine expressed individual views on the subject.

In accordance with the Chairman's letter, March 31, 1985, is the latest date for use of shift advisors. Beyond that date, utilities should plan to have sufficient operating experience on-shift such that there no longer is a need to rely on the use of shift advisors. We understand, of course, that circumstances may arise, beyond the control of the utility, which would mandate the use of advisors to cover one or more shifts, but these circumstances can be treated on a case-by-case basis.

The acceptance of these experience requirements by the NRC does not alter the guidance for eligibility, included in Regulatory Guide 1.8 and NUREG-0737, for RO and SRO licensing examination candidates. Further, acceptance of the Industry Working Group proposal does not foreclose the development of any long term requirements for crew operating experience.

We understand that each utility is in possession of a copy of the Industry Working Group proposal of February 24, 1984. Copies are also available from the NRC Public Document Room.

This letter contains no reporting requirement and is for information only.

Sincerely, Origimil 9ged by tobert A.forple f4 /EDarrell G. Eisenhut, Director Division of Licensing Enclosure:

Ltr of June 14, 1984

  • PREVIOUS CONCURRENCE SEE DATE

ORAB:DL* ORAB:DL* C:ORAB:DL* ELD* AD/SA:DL* D/DHFS9"'d- MFairtile:dm JZwolinski GHolahan FMiraglia HThompson DOssenhut

6/21/84 6/21/84 6/21/84 6/22/84 6/22/84 6/25/84 6/Zt384

8406270142.

X ,

'V :i .t.

June 27, l9 TO ALL LICENSEES OF OPERATING REACTORS, APPLICANTS FOR OPERATING

LICENSE, AND HOLDERS OF CONSTRUCTION PERMITS

Gentlemen:

SUBJECT: ADEQUACY OF ON-SHIFT OPERATING EXPERIENCE FOR

NEAR TERM OPERATING LICENSE APPLICANTS

(Generic Letter 84- )

On June 14, 1984, the Chairman of the U. S. Nuclear Regulatory Commission, N. J. Palladino, sent J. H. Miller, President, Georgia Power Company, a letter in which the Commissioners presented their views on the subject of adequacy of on-shift operating experience for near-term operating license applicants.

This letter is enclosed and is applicable for near-term operating license applicants.

The June 14, 1984 letter accepted, with some clarifications, an Industry Working Group proposal on this subject, presented to the Commission on February 24, 1984.

Commissioners Gilinsky and Asselstine expressed individual views on the subject.

In the Chairman's letter, March 31, 1985 is presented as an acceptable date beyond which utilities should plan to have sufficient operating experience on-shift such that there no longer is a need to rely on the use of shift advisors. We understand, of course, that circumstances may arise, beyond the control of the utility, which would mandate the use of advisors to cover one or more shifts, but these circumstances can be treated on a case-by-case basis.

The acceptance of these experience requirements by the NRC does not alter the guidance for eligibility, included in Regulatory Guide 1.8 and NUREG-0737, for RO and SRO licensing examination candidates. Further, acceptance of the Industry Working Group proposal does not foreclose the development of any long term requirements for crew operating experience.

We understand that each utility is in possession of a copy of the Industry Working Group proposal of February 24, 1984. Copies are also available from the NRC Public Document Room.

This letter contains no reporting requirement and is for information only.

Sincerely, Darrell G. Eisenhut, Director Division of Licensing Enclosure:

Ltr of June 14, 1984

  • PREVIOUS CONCURRENCE SEE DATE

ORAB:DL* ORAB:DL* C:ORAB:DL* ELD* AD/SA:DL* D/DHFS D/DL

MFairtile:dm JZwolinski GHolahan FMiraglia HThompson DEisenhut

6/21/84 6/21/84 6/?1/84 6/22/84 6/22/84 6/25/84 6/ /84 B0 AloeV

w 011VS.7

June 27, 34 TO ALL LICENSEES OF OPERATING REACTORS, APPLICANTS FOR OPERATING

LICENSE, AND HOLDERS OF CONSTRUCTION PERMITS

Gentlemen:

SUBJECT: ADEQUACY OF ON-SHIFT OPERATING EXPERIENCE FOR

NEAR TERM OPERATING LICENSE APPLICANTS

(Generic Letter 84- )

On June 14, 1984, the Chairman of the U. S. Nuclear Regulatory Commission, N. J. Palladino, sent J. H. Miller, President, Georgia Power Company, a letter in which the Commissioners presented their views on the subject of adequacy of on-shift operating experience for near-term operating license applicants. We believe the information contained in this letter to be informative and should be forwarded to all interested parties, thus we are sending this letter to you.

This letter is enclosed.

The June 14, 1984 letter is in response to an Industry Working Group proposal on this subject, presented to the Commission on February 24, 1984. Specifically, note the varied opinions on the guidance as expressed by the individual views of Commissioners Gilinsky and Asselstine. However, the Commission believes that the industry proposal with the given clarifications will provide reasonable assurance of adequate on-shift operating experience pending any further rulemaking the Commission might choose to undertake.

The acceptance of these experience requirements by the NRC does not alter the guidance for eligibility, included in Regulatory Guide 1.8 and NUREG-0737, for RO and SRO licensing examination candidates. Further, acceptance of this proposal is not intended to foreclose any long term requirements for crew operating experience which the staff may develop for Commission consideration that would apply to operating plants.

We understand that each utility is in possession of a copy of the Industry Working Group proposal of February 24, 1984. Copies are also available from the NRC Public Document Room.

This letter contains no reporting requirement and is for information only.

Sincerely, Darrell G. Eisenhut, Director Division of Licensing Enclosure:

Ltr of June 14, 1984 4L

ORAB:OT ORA14, C:ORAB:D R

EL " AD/ I D/DHFS D/DL

MFairtile:dm JZwolinski GHolahan FMir6Wa HThompson DEisenhut

6/ /84 6/I4/84 6/lk/84 6/P6 84 .3

6/g0 6/ /84 6/ /84

UNITED STATES

NUCLEAR REGULATORY COMMISSION

WASHINGTON, D. C. 2055 CHA AIRMAN June 14, 1984 Mr. J. H. Miller, President Georgia Power Company P. 0. Box 4545 Atlanta, Georgia 30302 Dear Mr. Miller:

The Commission appreciates the efforts you and the other members .of the Industry Working Group put forth in developing the proposal you presented to us on February 24, 1984, to assure the adequacy of on-shift operating experience for near-term operating license applicants. The level of utility participation in developing and supporting this proposal clearly reflects the needed degree of involvement by senior utility management to assure sound implementation.

The industry proposal recognizes that the use of shift advisors to supplement plant experietce depends upon the adequacy of the training of advisors and their integration into the shift crew. It is particularly important where advisors are used that there is a management commitment to (l) provide plant specific training for shift advisors which includes plant procedures, technical specifications, plant systems, and where available, time for use of a plant simulator, and (2) training for the remainder of the shift crew on the role of advisors. Furthermore, the industry proposal recognizes the desirability of phasing out the use of shift advisors as soon as is practically achievable, but proposed no specific date for terminating the use of advisors.

The Commission accepts the Industry Working Group proposal with the following clarifications:

With regard to the shift crews that meet the industry experience proposal:

1. The Hot Participation Experience tabulated in your slide 5 should be at a large, same type plant.

2. The use of an SRO-licensed STA to satisfy the Hot Participation Experience is acceptable provided that the STA serves as a member of the shift.

Mr. J. E. Miller -2- With regard to the use of shift advisors:

1. The shift advisors that have at least one year on shift as a licensed SRO at an operating plant of the same type are acceptable. Proposals to utilize an individual as an advisor who has only an RO license will be evaluated on a case-by-case basis to assure that an appropriate level of knowledge and supervisory experience has been accumulated.

2. The utility-administered examinations for advisors should include both oral and written examinations. If no plant-reference simulator is available, a board of at least three individuals, qualified at the SRO

level, should conduct the oral examination.

3. The utility should provide the NRC with a list of certified advisors and their qualifications. The NRC

staff should be notified one month prior to their release from the plant to which they are assigned.

Based upon operating experience, intormation submitted by individual utilities since the February 24, .1984 meeting, it appears that use of shift advisors may be required only at one plant now anticipating fuel load after March of 1985. Further, we understand that this utility is making plans to obtain necessary operating experience for its licensed operators prior to fuel load. Accordingly, it appears that March 31, 1985 would be an acceptable date beyond which utilities should plan to have sufficient operating experience on shift such that there no longer is a need to rely on the use of shift advisors.

We understand, of course, that circumstances may arise, beyond the control of the utility, which would mandate the use of advisors to cover one or more shifts, but these circumstances can be treated on a case-by-case basis.

The Commission believes that the industry proposal with the above clarifications will provide reasonable assurance of adequate on-shift operating experience pending any further rulemaking the Commission might choose to complete. The Commis- sion is therefore issuing a generic letter to all licensees which outlines this policy. The acceptance of these experience requirements by the NRC does not alter the guidance for eligi- bility, included in Regulatory Guide 1.8 and NUREG-0737, for RO

and SRO licensing examination candidates. Further, acceptance of this proposal is not intended to foreclose any long term

Mr. J. H. Miller -3- requirements for crew operating experience which the staff may develop for Commission consideration that would apply to operating plants.

Commissioner Asselstine adds:

I disagree with two aspects of the Commission's decision on the matter of shift experience requirements. first, I

do not believe that the "hot participation experience"

element in the industry proposal is adequate. I would only eliminate the requirement for a shift advisor if one licensed senior reactor operator on the shift has at least one year's prior experience as a licensed SRO at a similar plant. Without at least that amount of prior operating experience on the part of the shift crew, it seems prudent to me to require a shift advisor with that level of experience. Second, I believe that the matter of shift experience requirements should not be handled by means of a generic letter but rather should be the subject of a Commission policy statement. In my view, the Commission should have prepared a proposed policy statement on the subject and should have sougWt industry and public comment on it.

Commissioner Gilinsky adds:

Every recipient of this letter should understand its full implications. In pressuring the Commission to accept a feeble approach toward shift experience requirements at a few plants nearing operation, the industry is jeopardizing its long standing safety record. I do not think I have to underline what that means.

I would remind you that the original NRC staff proposal --

that at least one member of a shift have one year of previous licensed operating experience -- was very modest, as any experienced shift supervisor will tell you. It is also feasible -- I have attached an NRC staff memorandum on the number of experienced operators available. The suggestion that it is sufficient for the most senior person on shift to have six months of "hot participation",

of which only six weeks need be at power, is simply ridiculous. The Commissioners who approved this approach may not realize what they have done, but you do. It says to me the industry is not yet capable of policing its members.

Mr. J. H. Miller -4- I do not agree with the way the advisor issue is being handled, in particular the decision of the Commission not to require that advisors pass the equivalent of the two-day NRC SRO examination. I am not at all impressed by the two hour quiz administered by the utility seeking an operating permit. There are cases, and this is one of them, where going half-way is worse than doing nothing.

Rather than have advisors whose knowledge of the plant is in question, it would be better to have no advisors at all. Inexperienced supervisors may well disregard their training to follow the advice of an advisor installed by the NRC. If the advisor does not know the plant specifications and limitations, we could get into serious trouble.

Finally, the Commission's disregard of its existing regulation on operator experience at new plants, 10 CFR

55.25(b), and its General Counsel's advice on that point, does not encourage respect for the system of safety regulation. Neither does the Commission's promulgation of a major policy decision by means of an informal letter which three Commissioners vote4.not to discuss in public.

Thank you again for your efforts toward resolving this issue.

Sincerely, Nunzio J. Palladino Enclosure:

Memo dtd. 3/8/84 from W.J. Dircks to Cmr. Gllinsky (per Cmr. Gilinsky's additional views)

UNITED STATES

S0 . NUCLEAR REGULATORY COMMISSION

WASHINGTON. 0. C. 20555 A.1 Attached per Commissioner Gilinsky's added comments MEMORArNDUP' -?: Cc ner Gilinsky FROM:-- viiliai J. Dircks Executive Director for Operations SUBJECT: LIErNSED OPERATOR POOL

The s_:af has developed the enclosed responses to the questions you asked in your Karch 2, 1984, memorandum. The responses include our best estimate f-oc Infomnation in the Operator Licensing Tracking System (OLTS).

William J. Dircks Executive Director for Operations Enclosure:

As Stated cc: Chair-ar Failadino Commissioner Roberts Commiss;.oner Asselstine Con.m1issiorner Bernthal OGC

OPE

SECY

RESPONSES T0

COMMISSIONER GI!LINSKY'S QUESTIONS

ON LICENSED OPEIRATOR POOLS

1. How many Senior Reactor Operator (SP.O) licenses have been issued in the history of the NRC7 Response It is not Dossible to determine exactly how many SRO or RC licenses have been issued in the history of NRC. The Operator Licensing Tracking System (OLTS) was not initiated until 1982. Hard copy files were used before OLTS. The Privacy Act requires that record retention periods be established and maintained. Since the four year retention period for some of the earlier licenses has elapsed, the hard copy files of inactive operators were destroyed or purged of information prior to initiation of OLTS. These files cannot be recovered.

The totals that are indicated in OLTS as of March 5, 1984, are 4,505 SRO's and 3,231 RO's. This includes both power and non-power reactors.

We estimate that approximately 6O' cf. the licenses are for power reactors. Particularly for older dockets, the information in OLTS is difficult to verify; However, we consumer these fioures to be conservative estimates. There may be as many as 2,000 more operators and senior operators whose files have been purged. I hope this information is sufficient for your needs. For additional information to be generated, special programs will have To be developed or a hand count of the Regional dockets performed, delaying our work on upgrading the capability of the OLTS. This could ultimately cause delays in future requests.

2. How many Reactor Operator (RO) licenses have been issued?

ResDonse Same as Question 1.

3. How many SRO's have held a license for more than one year?

Response Of the licensed SRO's 1,040 have held a license for more than one year, but have not had the license renewed. This number does not include SRO's and RO's whose licenses have been renewed (Question 5).

.S

4. How imany RO's have held a license for more than one year?

ResDonse Of the licensed RO's, 1,457 have held a license for more than one year, but nave not had the licenses renewed.

5. How many SRO and RO licenses have been renewed at least once?

Response Of the licensed SRO's and RO's, 1,703 SRO's and 823 RO's have had their licenses renewed at least once.

.. 1 INDUSTRY WORKING GROUP

Arizona Public Service Company ATTN: Mr. J. R. Bynum Director, Nuclear Operations P. 0. Box 2166 Phoenix, Arizona 85036 Arizona Public Service Company Palo Verde --1 ATTN: Ron Younger Operations Superintendent P. 0. Box 2166 Phoenix, Arizona 85036 Carolina Power & Light Company ATTN: Mr. J. A. Jones Vice Chainman

411 Fayetteville Street Raleigh,. North Carolina 27602 Carolina Power & Light Company Shearon Harris ATTN: Mr. Al Cutter Vice President, Engineering & Licensing P. 0. Box 1551 Raleigh, North Carolina: 2760Z

Cleveland Electric Illuminating Company ATTN: Mr. Murray R. Edelman Vice President, Nuclear Group P. 0. Box 5000

Cleveland, Ohio 44101 Cleveland Electric Illuminating Company Perry Plant SB 307 ATTN: Mr. M. D. Lyster Plant Superintendent

10 Center Road Perry, Ohio 44081 Commonwealth Edison Company ATTN: Mr. Cordell Reed Vice President P. 0. Box 767 Chicago, Illinois 60690

Consumers Power Company ATTN: Mr. Russell B. DeWitt Vice President - Nuclear Operations

1945 West Parnall Road Jackson, Michigan 49201

Consumers Power Company Midland ATTN: Mr.. Joseph F. Firlit General Plant Manager

3249 East Gordonville Road Midland, Michigan 48640

Detroit Edison Company ATTN: Mr. Harry Tauber Group Vice President

2000 Second Avenue Detroit, Michigan 48226 Detroit Edison Company Fermi 2 ATTN: Mr. Wayne H. Jens Vice President Nuclear Operations

6400 North Dixie Highway New Port, Michigan 48166 Duke Power Company ATTN: Hal B. Tucker, Jr.

Vice President Nuclear Production Department P. 0. Box 33189 Charlotte. North Carolina 28242 Duquesne Light Company ATTN: Mr. E. J. Woolever Vice President, Beaver Valley II Project Robinson Plaza Building 2, Suite 210

Pennsylvania Rt. 60

Pittsburgh, Pennsylvania 152(05 Duquesne Light Company Beaver Valley 2 ATTN: Mr. Joseph F. Zagorski Station Superintendent P. 0. Box 4, New Training Bldg.

Shippingport, Pennsylvania 15077 Georgia Power Company ATTN: Mr. Doug Dutton Vice President-Project Management P. 0. Box 4545 Atlanta, Georgia 30302

Georgia Power Company Vogtle ATTN: Mr. George Bockhold, Jr.

General Manager, Vogtle Operations P. 0. Box 4545 Atlanta, Georgia 30302 gulf States Utilities Company ATTN: Mr. Jim Deddens Vice President - River Bend Nuclear Group P. 0. Box 2951 Beaumont, Texas 77704 Gulf States Utilities Company River Bend ATTN: Mr. W. H. Odell Director, Nuclear Training P. 0. Drawer 220

St. Francisville, LA 70775 Houston Lighting & Power Company ATTH: Mr. George A. Oprea, Jr.

Executive Vice President P. 0. Box 1700

Houston, Texas 77001 Houston Lighting & Power Company South Texas Project ATTN: Mr. Gary Helgeson Reactor Operations Superintendent P. 0. Box 1700

Houston, Texas 77001 Illinois Power Company ATTN: Mr. D. P. Hall Vice President

500 South 27th Street Decatur, Illinois 62525 Kansas Gas & Electric Company ATTN: Mr. Glenn L. Koester Vice President, Nuclear

201 North Market Street Wichita, Kansas 67201

Kansas Gas & Electric Company Wolf Creek ATTN: Mr. Paul E. Turner Manager, Nuclear Training

201 North Market Street Wichita, Kansas 67201 Long Island Lighting Company ATTN: Mr. M. S. Pollack Vice President-Nuclear

175 East Old Country Road Hicksville, New York 11801 Long Island Lighting Company ATTN: Mr. James W. Dye, Jr.

Senior Vice President

175 East Old Country Road Hicksville, New York 11801 Long Island Lighting Company ATTN: Mr. Jack Notaro Chief Operations Engineer

175 East Old Country Road Hicksville, New York 11801 Louisiana Power & Light Company ATTN: Mr. L. V. Maurin Vice President-Nuclear Operations

142 Delaronde Street New Orleans, Louisiana 70174 Louisiana Power & Light Company Waterford 3 ATTN: Mr. Ross P. Barkhurst Plant Manager P. 0. Box B

Killona, Louisiana 70066 Mississippi Power & Light Company ATTN: Mr. Jack B. Richard Senior Vice President-Nuclear P. 0. Box 1640

Jackson, Mississippi 39205 Niagara Mohawk Power Corporation ATTN: Mr. Gerald K. Rhode Senior Vice President

300 Erie Boulevard West Syracuse, New York 13202

Niagara Mohawk Power Corporation ATTN- Mr. Thomas E. Lempges Vice President, Nuclear

300 Erie Boulevard West Syracuse, New York 13202 Pacific Gas & Electric Company ATTNf: Mr. James 0. Schuyler Vice President, Nuclear

77 Beale Street San Francisco, California 94106 Pennsylvania Power and Light Company ATTN: Mr. Bruce D. Kenyon Nuclear Operations

2 North Ninth Street Allentown, Pennsylvania 18101 Philadelphia Electric Company ATTN: Mr. W. T. Ullrich Superintendent

2301 Market Street Philadelphia, Pennsylvania 19101 Public Service Company of New Hampshire ATTN: Mr. George S. Thomas Vice President, Nuclear Production P. 0. Box 330

Manchester, New Hampshire 03105 Public Service Electric & Gas Company ATTN: Mr. R. A. Underitz Vice President, Nuclear

80 Park Place, Room 816 MP

Newark, New Jersey 07101 Public Service Electric & Gas Company Hope Creek Generating Station ATTN: Mr. Roger S. Salvesen General Manager P. 0. Box 236 Hancocks Bridge, New Jersey 08038 Tennessee Valley Authority ATTN: Mr. H. G. Parris Manager of Power

500A Chestnut Tower II

Chattanooga, Tennessee 37401

Tennessee Valley Authority Watts Bar ATTN: Mr. William T. Cottle Power Plant Superintendent P. 0. Box 800

Spring City, Tennessee 37381 Texas Utilities Generating Company ATTN: Mr. R. J. Gary. Executive Vice President & General Manager

2001 Bryan Tower Dallas, Texas 75201 Texas Utilities Generating Company Comanche Peak ATTN: Mr. J. C. Kuykendall Manager, Nuclear Operations

2001 Bryan Tower Dallas, Texas 75201 Union Electric Company ATTN: Mr. D. F. Schnell Vice President - Nuclear'

P. O. Box 149 -

St. Louis, Missouri 63166 Union Electric Company ATTN: Mr. E. K. Dille Executive Vice President P. 0. Box 149 St. Louis, Missouri 63166 Union Electric Company ATTN: Mr. Steve Miltenberger Manager, Callaway P. 0. Box 149 St. Louis, Missouri 63166 Washington Public Power Supply System ATTN: Mr. 0. W. Mazur Managing Director

3000 George Washington Way P. 0. Box 968 Richland, Washington 99352 Washington Public Power Supply System ATTN: Mr. Robert Glasscock Manager, QA

3000 George Washington Way P. 0. Box 968 Richland, Washington 99352

Template:GL-Nav