NOC-AE-17003536, ERDS Data Point Library Change Submittal

From kanterella
Jump to navigation Jump to search
ERDS Data Point Library Change Submittal
ML18030A504
Person / Time
Site: South Texas  STP Nuclear Operating Company icon.png
Issue date: 01/30/2018
From: Marc-Anthony Murray
South Texas
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NOC-AE-17003536, STI: 34585603
Download: ML18030A504 (14)


Text

Nuclear Operating Company South Texas Protect Electric Generating Station RO.Box28? Wadsworth, Texas77483 January 30,2018 NOC-AE-17003536 10CFR 50 Appendix E STI:34585603 Attention: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 South Texas Project Units 1 and 2 Docket Nos. STN 50-498; STN 50-499 ERDS Data Point Library Change Submittal The Emergency Response Data System (ERDS) Data Point Library (DPL) for South Texas Project (STP) Units 1 and 2 was submitted in ST-HL-AE-4028, dated March 5, 1992. The attached changes are submitted in accordance with the provisions of that letter as prescribed in 10 CFR Part 50, Appendix E, VI.S.a and NUREG 1394, Rev. 1, Section 3.6.

There are no NRC commitments in this letter.

If you should have any questions on this matter, please contact Marilyn Kistler at (361)972-8385.

Michael K Murray Manager, Regulatory Affairs Attachments: 1. Emergency Response Data System - Data Point Library Changes (Replacement Pages) for STP Unit 1 (ST1)

Emergency Response Data System - Data Point Library Changes (Replacement Pages) for STP Unit 2(ST2)

NOC-AE-17003536 Page 2 of 2 ec:

(paper copy) (electronic copy)

Regional Administrator, Region IV Moman, Lewis & Bockius LLP U.S. Nuclear Regulatory Commission Paul Bessette 1600 East Lamar Boulevard Arlington, TX 76011-4511 U.S. Nuclear Regulatory Commission Lisa M. Regner Lisa M. Regner Senior Project Manager NRG South Texas LP U.S. Nuclear Regulatory Commission Mark Walker One White Flint North (08H04) Jim von Suskil 11555RockvillePike Skip Zahn Rockville, MD 20852 CPS Energy NRC Resident Inspector Kevin Polio U. S. Nuclear Regulatory Commission Cris Eugster P. 0. Box 289, Mail Code: MN116 L. D. Blaylock Wadsworth,TX 77483 City of Austin Elaina Ball John Wester Texas Dept. of State Health Services Helen Watkins Robert Free

NOC-AE-17003536 Attachment 1 Emergency Response Data System - Data Point Library Changes (Replacement Pages) for STP Unit 1 (ST1)

PAGE 9 SOUTH TEXAS PROJECT - UNIT 1 DATA POINT LIBRARY REFERENCE FILE Date 12/28/2017 Reactor Unit ST1 Data Feeder 1 NRC ERDS Parameter NOT LISTED Point ID EMSU0001 Plant Spec Point Desc PRI 10M WIND SPEED 15 MIN AVG Generic/Cond Desc WIND SPEED AT 10M REACTOR SITE Analog/Digital A Engr Units/Dig States MPH Engr Units Conversion N/A Minimum Instr Range 0 Maximum Instr Range 100 Zero Point Reference N/A Reference Point Notes N/A PROC or SENS s Number of Sensors 1 How Processed N/A Sensor Locations PRIMARY MET TOWER AT 10 METERS Alarm/Trip Set Points N/A N1 Detector Power Supply Cut-off Power Level N/A N1 Detector Power Supply Turn-on Power Level N/A Instrument Failure Mode Temperature Compensation For DP Transmitters Level Reference Leg N/A Unique System Desc 15 MINUTE AVERAGE, UPDATED EVERY 15 MINUTES REAL TIME DATA AVAILABLE ON ERFDADS/ICS. MOVE VALUE FROM EMSN0001

PAGE 10 SOUTH TEXAS PROJECT - UNIT 1 DATA POINT LIBRARY REFERENCE FILE Date 12/28/2017 Reactor Unit ST1 Data Feeder 1 NRC ERDS Parameter NOT LISTED Point ID EMSU0008 Plant Spec Point Desc PRI 60M WIND SPEED 15 MIN AVG Generic/Cond Desc WIND SPEED AT 60M REACTOR SITE Analog/Digital A Engr Units/Dig States MPH Engr Units Conversion N/A Minimum Instr Range 0 Maximum Instr Range 100 Zero Point Reference N/A Reference Point Notes N/A PROC or SENS s Number of Sensors 1 How Processed N/A Sensor Locations PRIMARY MET TOWER AT 60 METERS Alarm/Trip Set Points N/A N1 Detector Power Supply Cut-off Power Level N/A N1 Detector Power Supply Turn-on Power Level N/A Instrument Failure Mode Temperature Compensation For DP Transmitters Level Reference Leg N/A Unique System Desc 15 MINUTE AVERAGE, UPDATED EVERY 15 MINUTES REAL TIME DATA AVAILABLE ON ERFDADS/ICS. MOVE VALUE FROM EMSN0008

PAGE 11 SOUTH TEXAS PROJECT - UNIT 1 DATA POINT LIBRARY REFERENCE FILE Date 12/28/2017 Reactor Unit ST1 Data Feeder 1 NRC ERDS Parameter NOT LISTED Point ID EMSU0009 Plant Spec Point Desc PRI 60M WIND DIR 15 MIN AVG Generic/Cond Desc WIND DIR AT 60M REACTOR SITE Analog/Digital A Engr Units/Dig States DEG Engr Units Conversion N/A Minimum Instr Range 0 Maximum Instr Range 360 Zero Point Reference N/A Reference Point Notes N/A PROC or SENS s Number of Sensors 1 How Processed N/A Sensor Locations PRIMARY MET TOWER AT 60 METERS Alarm/Trip Set Points N/A N1 Detector Power Supply Cut-off Power Level N/A N1 Detector Power Supply Turn-on Power Level N/A Instrument Failure Mode Temperature Compensation For DP Transmitters Level Reference Leg N/A Unique System Desc 15 MINUTE AVERAGE, UPDATED EVERY 15 MINUTES REAL TIME DATA AVAILABLE ON ERFDADS/ICS. MOVE VALUE FROM EMSN0009. WIND DIRECTION USES "FROM"!

CONVENTION.

PAGE 12 SOUTH TEXAS PROJECT - UNIT 1 DATA POINT LIBRARY REFERENCE FILE Date 12/28/2017 Reactor Unit ST1 Data Feeder 1 NRC ERDS Parameter NOT LISTED Point ID EMTU0004 Plant Spec Point Desc PRI DELTA TEMP 15 MIN AVG Generic/Cond Desc AIR STABILITY AT REACTOR SITE Analog/Digital A Engr Units/Dig States DEGF Engr Units Conversion N/A Minimum Instr Range -8 Maximum Instr Range +12 Zero Point Reference N/A Reference Point Notes N/A PROCorSENS p Number of Sensors 2 How Processed SEE BELOW Sensor Locations PRIMARY MET TOWER ONE AT 10 METER AND ONE AT 60 METER Alarm/Trip Set Points N/A N1 Detector Power Supply Cut-off Power Level N/A N1 Detector Power Supply Turn-on Power Level N/A Instrument Failure Mode Temperature Compensation For DP Transmitters Level Reference Leg N/A Unique System Desc 15 MINUTE AVERAGE, UPDATED EVERY 15 MINUTES.

REAL TIME DATA AVAILABLE ON ERFDADS/ICS. MOVE VALUE FROM EMTN0004. ONE TEMPERATURE SENSOR AT EACH ELEVATION.

THE 10 METER TEMPERATURE VALUE IS SUBTRACTED FROM THE 60 METER TEMPERATURE VALUE IN THE MET DATA LOGGER. THE RAW DELTA TEMPERATURE CALCULATION IS BASED UPON DEGF PER 50 METER ELEVATION DIFFERENCE.

PAGE 13 SOUTH TEXAS PROJECT- UNIT 1 DATA POINT LIBRARY REFERENCE FILE Date 12/28/2017 Reactor Unit ST1 Data Feeder 1 NRC ERDS Parameter NOT LISTED Point ID EMXU0002 Plant Spec Point Desc PRI 10M WIND DIR 15 MIN AVG Generic/Cond Desc WIND DIR AT 10M REACTOR SITE Analog/Digital A Engr Units/Dig States DEG Engr Units Conversion N/A Minimum Instr Range 0 Maximum Instr Range 360 Zero Point Reference N/A Reference Point Notes N/A PROCorSENS s Number of Sensors 1 How Processed N/A Sensor Locations PRIMARY MET TOWER AT 10 METERS Alarm/Trip Set Points N/A N1 Detector Power Supply Cut-off Power Level N/A N1 Detector Power Supply Turn-on Power Level N/A Instrument Failure Mode Temperature Compensation For DP Transmitters Level Reference Leg N/A Unique System Desc 15 MINUTE AVERAGE, UPDATED EVERY 15 MINUTES REAL TIME DATA AVAILABLE ON ERFDADS/ICS.

MOVE VALUE FROM EMXN0002. WIND DIRECTION USES "FROM" CONVENTION.

NOC-AE-17003536 Attachment 2 Emergency Response Data System - Data Point Library Changes (Replacement Pages) for STP Unit 2 (ST2)

PAGE 9 SOUTH TEXAS PROJECT - UNIT 2 DATA POINT LIBRARY REFERENCE FILE Date 12/28/2017 Reactor Unit ST2 Data Feeder 1 NRC ERDS Parameter NOT LISTED Point ID EMSU0001 Plant Spec Point Desc PRI 10M WIND SPEED 15 MIN AVG Generic/Cond Desc WIND SPEED AT 10M REACTOR SITE Analog/Digital A Engr Units/Dig States MPH Engr Units Conversion N/A Minimum Instr Range 0 Maximum Instr Range 100 Zero Point Reference N/A Reference Point Notes N/A PROC or SENS s Number of Sensors How Processed N/A Sensor Locations PRIMARY MET TOWER AT 10 METERS Alarm/Trip Set Points N/A N1 Detector Power Supply Cut-off Power Level N/A N1 Detector Power Supply Turn-on Power Level N/A Instrument Failure Mode Temperature Compensation For DP Transmitters Level Reference Leg N/A Unique System Desc 15 MINUTE AVERAGE, UPDATED EVERY 15 MINUTES REAL TIME DATA AVAILABLE ON ERFDADS/ICS. MOVE VALUE FROM EMSN0001

PAGE 10 SOUTH TEXAS PROJECT - UNIT 2 DATA POINT LIBRARY REFERENCE FILE Date 12/28/2017 Reactor Unit ST2 Data Feeder 1 NRC ERDS Parameter NOT LISTED Point ID EMSU0008 Plant Spec Point Desc PRI 60M WIND SPEED 15 MIN AVG Generic/Cond Desc WIND SPEED AT 60M REACTOR SITE Analog/Digital A Engr Units/Dig States MPH Engr Units Conversion N/A Minimum Instr Range 0 Maximum Instr Range 100 Zero Point Reference N/A Reference Point Notes N/A PROC or SENS s Number of Sensors 1 How Processed N/A Sensor Locations PRIMARY MET TOWER AT 60 METERS Alarm/Trip Set Points N/A N1 Detector Power Supply Cut-off Power Level N/A N1 Detector Power Supply Turn-on Power Level N/A Instrument Failure Mode Temperature Compensation For DP Transmitters Level Reference Leg N/A Unique System Desc 15 MINUTE AVERAGE, UPDATED EVERY 15 MINUTES REAL TIME DATA AVAILABLE ON ERFDADS/ICS. MOVE VALUE FROM EMSN0008

PAGE 11 SOUTH TEXAS PROJECT - UNIT 2 DATA POINT LIBRARY REFERENCE FILE Date 12/28/2017 Reactor Unit ST2 Data Feeder 1 NRC ERDS Parameter NOT LISTED Point ID EMSU0009 Plant Spec Point Desc PRI 60M WIND DIR 15 MIN AVG Generic/Cond Desc WIND DIR AT 60M REACTOR SITE Analog/Digital A Engr Units/Dig States DEG Engr Units Conversion N/A Minimum Instr Range 0 Maximum Instr Range 360 Zero Point Reference N/A Reference Point Notes N/A PROCorSENS s Number of Sensors 1 How Processed N/A Sensor Locations PRIMARY MET TOWER AT 60 METERS Alarm/Trip Set Points N/A N1 Detector Power Supply Cut-off Power Level N/A N1 Detector Power Supply Turn-on Power Level N/A Instrument Failure Mode Temperature Compensation For DP Transmitters Level Reference Leg N/A Unique System Desc 15 MINUTE AVERAGE, UPDATED EVERY 15 MINUTES REAL TIME DATA AVAILABLE ON ERFDADS/ICS. MOVE VALUE FROM EMSN0009. WIND DIRECTION USES "FROM" CONVENTION.

PAGE 12 SOUTH TEXAS PROJECT - UNIT 2 DATA POINT LIBRARY REFERENCE FILE Date 12/28/2017 Reactor Unit ST2 Data Feeder 1 NRC ERDS Parameter NOT LISTED Point ID EMTU0004 Plant Spec Point Desc PRI DELTA TEMP 15 MIN AVG Generic/Cond Desc AIR STABILITY AT REACTOR SITE Analog/Digital A Engr Units/Dig States DEGF Engr Units Conversion N/A Minimum Instr Range -8 Maximum Instr Range +12 Zero Point Reference N/A Reference Point Notes N/A PROC or SENS p Number of Sensors 2 How Processed SEE BELOW Sensor Locations PRIMARY MET TOWER ONE AT 10 METER AND ONE AT 60 METER Alarm/Trip Set Points N/A N1 Detector Power Supply Cut-off Power Level N/A N1 Detector Power Supply Turn-on Power Level N/A Instrument Failure Mode Temperature Compensation For DP Transmitters Level Reference Leg N/A Unique System Desc 15 MINUTE AVERAGE, UPDATED EVERY 15 MINUTES.

REAL TIME DATA AVAILABLE ON ERFDADS/ICS, MOVE VALUE FROM EMTN0004. ONE TEMPERATURE SENSOR AT EACH ELEVATION.

THE 10 METER TEMPERATURE VALUE IS SUBTRACTED FROM THE 60 METER TEMPERATURE VALUE IN THE MET DATA LOGGER. THE RAW DELTA TEMPERATURE CALCULATION IS BASED UPON DEGF PER 50 METER ELEVATION DIFFERENCE,

PAGE 13 SOUTH TEXAS PROJECT - UNIT 2 DATA POINT LIBRARY REFERENCE FILE Date 12/28/2017 Reactor Unit ST2 Data Feeder 1 NRC ERDS Parameter NOT LISTED Point ID EMXU0002 Plant Spec Point Desc PRI 10M WIND DIR 15 MIN AVG Generic/Cond Desc WIND DIR AT 10M REACTOR SITE Analog/Digital A Engr Units/Dig States DEG Engr Units Conversion N/A Minimum Instr Range 0 Maximum Instr Range 360 Zero Point Reference N/A Reference Point Notes N/A PROCorSENS s Number of Sensors 1 How Processed N/A Sensor Locations PRIMARY MET TOWER AT 10 METERS Alarm/Trip Set Points N/A N1 Detector Power Supply Cut-off Power Level N/A N1 Detector Power Supply Turn-on Power Level N/A Instrument Failure Mode Temperature Compensation For DP Transmitters Level Reference Leg N/A Unique System Desc 15 MINUTE AVERAGE, UPDATED EVERY 15 MINUTES REAL TIME DATA AVAILABLE ON ERFDADS/ICS. MOVE VALUE FROM EMXN0002. WIND DIRECTION USES "FROM" CONVENTION.