ML993540247

From kanterella
Jump to navigation Jump to search
IRC Harris 1999005 Integrated
ML993540247
Person / Time
Issue date: 09/23/1999
From:
Division Reactor Projects II
To:
References
Download: ML993540247 (14)


Text

September 23, 1999 Carolina Power & Light Company ATTN: Mr. James Scarola Vice President - Harris Plant Shearon Harris Nuclear Power Plant P. O. Box 165, Mail Code: Zone 1 New Hill, NC 27562-0165

SUBJECT:

NRC INTEGRATED INSPECTION REPORT 50-400/99-05

Dear Mr. Scarola:

On August 28, 1999, the NRC completed an inspection at your Shearon Harris facility. The enclosed report presents the results of that inspection. The results of the inspection were discussed with you and other members of your staff on September 2, 1999.

The inspection was an examination of activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license. Within these areas, the inspection consisted of a selective examination of procedures and representative records, observations of activities, and interviews with personnel. Specifically the inspection covered periodic resident inspections and a scheduled public radiation safety inspection.

In accordance with 10 CFR 2.790 of the NRC's "Rules of Practice," a copy of this letter and its enclosure will be placed in the NRC Public Document Room (PDR).

Sincerely, (Original signed by Brian R. Bonser)

Brian R. Bonser, Chief Reactor Projects Branch 4 Division of Reactor Projects Docket No.: 50-400 License No.: NPF-63

Enclosure:

NRC Integrated Inspection Report cc w\\encl: (See page 2)

CP&L 2

cc w/encl:

Terry C. Morton, Manager Performance Evaluation and Regulatory Affairs CPB 9 Carolina Power & Light Company Electronic Mail Distribution Chris L. Burton Director of Site Operations Carolina Power & Light Company Shearon Harris Nuclear Power Plant Electronic Mail Distribution Bo Clark Plant General Manager--Harris Plant Carolina Power & Light Company Shearon Harris Nuclear Power Plant Electronic Mail Distribution Donna B. Alexander, Manager Regulatory Affairs Carolina Power & Light Company Shearon Harris Nuclear Power Plant Electronic Mail Distribution Johnny H. Eads, Supervisor Licensing/Regulatory Programs Carolina Power & Light Company Shearon Harris Nuclear Power Plant Electronic Mail Distribution William D. Johnson Vice President & Corporate Secretary Carolina Power & Light Company Electronic Mail Distribution John H. O'Neill, Jr.

Shaw, Pittman, Potts & Trowbridge 2300 N. Street, NW Washington, DC 20037-1128 Mel Fry, Director Division of Radiation Protection N. C. Department of Environmental Commerce & Natural Resources Electronic Mail Distribution Peggy Force Assistant Attorney General State of North Carolina Electronic Mail Distribution Public Service Commission State of South Carolina P. O. Box 11649 Columbia, SC 29211 Chairman of the North Carolina Utilities Commission P. O. Box 29510 Raleigh, NC 27626-0510 Robert P. Gruber Executive Director Public Staff NCUC P. O. Box 29520 Raleigh, NC 27626 Vernon Malone, Chairman Board of County Commissioners of Wake County P. O. Box 550 Raleigh, NC 27602 Richard H. Givens, Chairman Board of County Commissioners of Chatham County Electronic Mail Distribution Distribution w/encl: (See page 3)

CP&L 3

Distribution w/encl:

R. Laufer, NRR PUBLIC OFFICE DRP/RII DRP/RII DRP/RII DRS/RII SIGNATU NAME GMacDonal JBrady BHagar ETesta DATE 6/

6/ 6/ /25 6/ /25 6/

6/

6/

COPY?

YES YES YES YES YES YES YES OFFICIAL RECORD COPY DOCUMENT NAME: I:\\RPB4\\HARRIS\\Report\\99_05.wpd

U. S. NUCLEAR REGULATORY COMMISSION REGION II Docket No:

50-400 License No:

NPF-63 Report No:

50-400/99-05 Licensee:

Carolina Power & Light (CP&L)

Facility:

Shearon Harris Nuclear Power Plant, Unit 1 Location:

5413 Shearon Harris Road New Hill, NC 27562 Dates:

July 18 - August 28, 1999 Inspectors:

J. Brady, Senior Resident Inspector R. Hagar, Resident Inspector E. Testa, Senior Radiation Specialist (Sections 2PS1 and 2PS3)

Approved by:

B. Bonser, Chief, Projects Branch 4 Division of Reactor Projects

SUMMARY

OF FINDINGS Shearon Harris Nuclear Power Plant, Unit 1 NRC Inspection Report 50-400/99-05 The report covers a six-week period of resident inspection. In addition, it includes the results of announced inspections by a regional senior radiation specialist.

Performance Indicators Verification The initiating events cornerstone performance indicators were reviewed and verified. These included Unplanned Scrams Per 7,000 Critical Hours, Scrams With A Loss Of Normal Heat Removal, and Unplanned Power Changes Per 7,000 Critical Hours. Two years of data was reviewed. No findings were identified.

No findings were identified during this inspection period.

Report Details The unit was at essentially 100% power for the entire period.

1.

REACTOR SAFETY Cornerstones: Initiating Events, Mitigating Systems, Barrier Integrity 1R03 Emergent Work

a.

Inspection Scope The inspectors reviewed the emergent items described in the following Work Requests/Job Orders (WRJOs):

WR/JO Title 98-AGUQ1 Replace the leaking gasket(s) for 1CS-E016 (excess letdown heat exchanger) 99-AFYL1 Emergency Service Water Pump main reservoir traveling screen will not rotate due to broken coupling 99-AGDL1 A vacuum pump would not stay running

b.

Observations and Findings No findings were identified and documented through this inspection.

1R04 Equipment Alignment

a.

Inspection Scope The inspectors performed a detailed review of the emergency diesel generator (EDG) system. This included a review of the Final Safety Analysis Report, and system descriptions; a review of the status of work orders and condition reports (CR) with the system engineer; and a walkdown of the EDG system.

b.

Observations and Findings No findings were identified and documented through this inspection.

1R05 Fire Protection

a.

Inspection Scope The inspectors reviewed the high fire risk areas which included four fire zones that did not screen out using the Fire Induced Vulnerability Evaluation methodology in the Individual Plant Examination for External Events (IPEEE). Two zones contained the control room envelope and the other two contained the two switchgear rooms. The

3 inspectors also discussed the fire drill schedule with the licensee to determine when drills would be conducted in the high fire risk areas.

b.

Observations and Findings No findings were identified and documented in relation to inspection of the high fire risk areas.

The inspectors observed that no drills were scheduled in the switchgear areas. In discussing this with the licensee, the inspectors learned that no fire drill in these areas had been scheduled in at least the past seven years. The licensee had decided that since full scale fire drills in the switchgear rooms could inadvertently initiate plant events, drills would not be conducted in those areas. The IPEEE indicated that the core damage frequency contribution from the two switchgear rooms was 3.1E-6/year and 4.0E-6/year (highest of any room in the plant). The licensee initiated CR 99-01973 to review the fire brigade training for the switchgear areas and to reassess the decision not to conduct drills there.

1R09 Inservice Testing (IST) of Pumps and Valves

a.

Inspection Scope The inspectors reviewed the performance of the following IST tests:

Number Rev.

Title OST-1041 5

A Train Heating Ventilation and Air Conditioning (HVAC) Safety Related Essential Service Chilled Water (ESCW) Temperature Control Valves (TCVs) Inservice Inspection (ISI) Operability Test OST-1085 13 1A-SA Diesel Generator Operability Test Semiannual Interval MST-I0116 11 Hydrogen Monitor Operability Test

b.

Observations and Findings No findings were identified and documented through this inspection.

1R12 Maintenance Rule Implementation

a.

Inspection Scope The inspectors reviewed the licensees implementation of the Maintenance Rule (10 CFR 50.65) with respect to the equipment issues described in the following CRs:

CR 99-01450 Emergency Safeguards Sequencer relay 2-30/1161 was found out of tolerance

4 CR 99-01808 Turbine Driven Auxiliary Feedwater Manual/Automatic station failed CR 99-02087-1 A Waste Gas Compressor Breaker tripped

b.

Observations and Findings No findings were identified and documented through this inspection.

1R13 Maintenance Work Prioritization & Control

a.

Inspection Scope The inspectors reviewed the licensees assessments of the risk impacts of removing from service the components associated with the Emergent Work items listed in section 1R03.

b.

Observations and Findings No findings were identified and documented through this inspection.

1R14 Nonroutine Evolutions

a.

Inspection Scope The inspectors observed the operating crews performance during the following non-routine evolutions:

Placing excess letdown in service and removing normal letdown from service, August 4, 1999, and August 12-13, 1999, and Response to unidentified reactor coolant system leakage greater than Technical Specification limits, August 4, 1999.

b.

Observations and Findings No findings were identified and documented through this inspection.

1R15 Operability Evaluations

a.

Inspection Scope The inspectors reviewed the operability evaluations described in the following Engineering Service Requests (ESRs):

ESR No.

Rev.

Title

5 99-00254 0

Operability Determination for Preaction and Multicycle System 99-00323 0

Excess Letdown Heat Exchanger Piping Operability Determination 99-00331 0

Operability Determination for Response Spectrum Analyzer

b.

Observations and Findings No findings were identified and documented through this inspection.

1R16 Operator Workarounds

a.

Inspection Scope The inspectors reviewed the operator work-around associated with operating the letdown pressure control valve in manual rather than automatic control. The inspectors reviewed plant conditions to assess whether operator work-around items were being identified in the operator work-around program.

b.

Observations and Findings The inspectors observed a fire alarm in the EDG building and the licensees investigation of that alarm. The investigation revealed that the alarm was spurious and was caused by the starting of the motor driven fire pump (MDFP). Licensee operations personnel revealed that these spurious alarms occur frequently when the MDFP is started. The inspectors determined that spurious alarms would direct operator attention and fire brigade response from a real fire. As a result, the licensee initiated CR 99-02369 to document this condition and added the work-around to the program. No findings were identified and documented through this inspection.

1R19 Post Maintenance Testing

a.

Inspection Scope The inspectors reviewed the following post-maintenance tests:

Number Rev.

Title Related maintenance task EPT-33 20 Emergency Safeguards 99-AEZK1, Replace 2 relays Sequencer System Test in A emergency sequencer OST-1085 13 1A-SA Diesel

6 Generator Various preventive-Operability Test Semiannual maintenance tasks Interval OST-1032 9

Reactor Auxiliary Building 99-ADUF1, Replace E-6 fan Emergency Exhaust System outboard bearing Train A Operability Monthly Interval Modes 1-4

b.

Observations and Findings No findings were identified and documented through this inspection.

1R22 Surveillance Testing

a.

Inspection Scope The inspectors reviewed the following surveillance tests:

OST-1026, Reactor Coolant System Leakage Evaluation, Computer Calculation, Daily Interval, Modes 1-2-3-4, Revision 12 MST-I0145, Steam Generator A Narrow Range Level Loop (L-0476) Operational Test, Revision 4 MST I0146, Steam Generator B Narrow Range Level Loop (L-0484) Operational Test, Revision 4

b.

Observations and Findings No findings were identified and documented through this inspection.

Cornerstone: Emergency Preparedness 1EP1 Drill, Exercise, and Actual Events

a.

Inspection Scope The inspectors reviewed licensee participation in the August 26, 1999, emergency drill.

b.

Observations and Findings No findings were identified and documented through this inspection.

7

2.

RADIATION SAFETY Cornerstone: Public Radiation Safety 2PS1 Gaseous and Liquid Effluent Treatment Systems

a.

Inspection Scope The inspectors reviewed the licensees performance to ensure that the gaseous and liquid effluent processing systems are maintained so that radiological releases are properly mitigated, monitored, and evaluated to limit public exposure.

b.

Observations and Findings No findings were identified and documented through this inspection.

2PS3 Radiological Environmental Monitoring Program

a.

Inspection Scope The inspectors reviewed the licensees performance in implementing the Radiological Environmental Monitoring Program (REMP) as required by Technical Specifications and the Offsite Dose Calculation Manual (OCDM).

b.

Observations and Findings No findings were identified and documented through this inspection.

4.

OTHER ACTIVITIES 4OA2 Performance Indicator Verification

a.

Inspection Scope The inspectors reviewed and verified the July 1999 performance indicator data for all of the initiating events cornerstone performance indicators. The inspectors reviewed two years of data that included inspection reports, monthly operating reports and operator logs.

b.

Observations and Findings No findings were identified and documented through this inspection.

8 4OA5 Management Meetings

.1 Exit Meeting Summary The inspectors presented the inspection results to members of licensee management on September 2, 1999. The licensee acknowledged the findings presented.

The inspectors asked the licensee whether any of the material examined during the inspection should be considered proprietary. No proprietary information was identified.

9 PARTIAL LIST OF PERSONS CONTACTED Licensee D. Alexander, Manager, Regulatory Affairs C. Burton, Director, Site Operations B. Clark, General Manager, Harris Plant R. Field, Manager, Nuclear Assessment T. Hobbs, Acting Manager, Operations J. Holt, Manager, Outage and Scheduling G. Kline, Manager, Harris Engineering Support Services J. Scarola, Vice President, Harris Plant B. Waldrep, Manager, Maintenance E. Wills, Manager, Environmental & Radiation Control NRC B. Bonser, Chief, Reactor Projects Branch 4 R. Laufer, Harris Project Manager, NRR

10 ITEMS OPENED, CLOSED, AND DISCUSSED Opened None Closed None Discussed None