ML25336A268

From kanterella
Jump to navigation Jump to search
Commercial Grade Dedication Inspection Report 05000382/2025010
ML25336A268
Person / Time
Site: Waterford 
Issue date: 12/03/2025
From: Wes Cullum
NRC/RGN-IV/DORS/EB1
To: Sullivan J
Entergy Operations
References
IR 2025010
Download: ML25336A268 (0)


See also: IR 05000382/2025010

Text

December 03, 2025

Joseph Sullivan, Site Vice President

Entergy Operations, Inc.

17265 River Road

Killona, LA 70057

SUBJECT:

WATERFORD STEAM ELECTRIC STATION, UNIT 3 - COMMERCIAL GRADE

DEDICATION INSPECTION REPORT 05000382/2025010

Dear Joseph Sullivan:

On September 24, 2025, the U.S. Nuclear Regulatory Commission (NRC) completed an

inspection at Waterford Steam Electric Station, Unit 3 and discussed the results of this

inspection with David Oertling and other members of your staff. The results of this inspection

are documented in the enclosed report.

Due to the temporary cessation of government operations, which commenced on October 1,

2025, the NRC began operating under its Office of Management and Budget-approved plan for

operations during a lapse in appropriations. Consistent with that plan, the NRC operated at

reduced staffing levels throughout the duration of the shutdown. However, the NRC continued to

perform critical health and safety functions and make progress on other high-priority activities

associated with the ADVANCE Act and Executive Order 14300. On November 13, 2025,

following the passage of a continuing resolution, the NRC resumed normal operations.

However, due to the 43-day lapse in normal operations, the Office of Nuclear Reactor

Regulation granted the Regional Offices an extension on the issuance of inspection reports that

could not be issued within 45 days after the end of the inspection because of the shutdown.

No findings or violations of more than minor significance were identified during this inspection.

This letter, its enclosure, and your response (if any) will be made available for public inspection

and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document

Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public

Inspections, Exemptions, Requests for Withholding.

Sincerely,

Wes L. Cullum, Chief

Engineering Branch 1

Division of Operating Reactor Safety

Signed by Cullum, Wes

on 12/03/25

J. Sullivan

2

Docket No. 05000382

License No. NPF-38

Enclosure:

As stated

cc w/ encl: Distribution via LISTSERV

ML25336A268

SUNSI Review

ADAMS:

Non-Publicly Available

Non-Sensitive

By: RJK

Yes No

Publicly Available

Sensitive

OFFICE

RI:DORS/EB1

RI:DORS/EB1

SPE:DORS/PBC

C:DORS/EB1

NAME

DBryen

BNwafor

RKumana

WCullum

SIGNATURE

/RA/

/RA/

/RA/

/RA/

DATE

12/03/25

12/02/25

12/03/25

12/03/25

Enclosure

U.S. NUCLEAR REGULATORY COMMISSION

Inspection Report

Docket Number:

05000382

License Number:

NPF-38

Report Number:

05000382/2025010

Enterprise Identifier:

I-2025-010-0041

Licensee:

Entergy Operations, Inc.

Facility:

Waterford Steam Electric Station, Unit 3

Location:

Killona, LA

Inspection Dates:

September 08, 2025, to September 24, 2025

Inspectors:

D. Bryen, Reactor Inspector

R. Kumana, Senior Project Engineer

B. Nwafor, Reactor Inspector

Approved By:

Wes L. Cullum, Chief

Engineering Branch 1

Division of Operating Reactor Safety

2

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees

performance by conducting a commercial grade dedication inspection at Waterford Steam

Electric Station, Unit 3, in accordance with the Reactor Oversight Process. The Reactor

Oversight Process is the NRCs program for overseeing the safe operation of commercial

nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more

information.

List of Findings and Violations

No findings or violations of more than minor significance were identified.

Additional Tracking Items

Type

Issue Number

Title

Report Section

Status

CAPR

05000382/2024040-07

Waterford 95001 CAPR CR-

WF3-2024-03099-00084

Develop and Incorporate

Quality Requirements for

Replacement Relays

71111.21N.03

Closed

3

INSPECTION SCOPES

Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in

effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with

their attached revision histories are located on the public website at http://www.nrc.gov/reading-

rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared

complete when the IP requirements most appropriate to the inspection activity were met

consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection

Program - Operations Phase. The inspectors reviewed selected procedures and records,

observed activities, and interviewed personnel to assess licensee performance and compliance

with Commission rules and regulations, license conditions, site procedures, and standards.

REACTOR SAFETY

71111.21N.03 - Commercial Grade Dedication

Commercial Grade Dedication (9 Samples)

(1)

Item Number 00022950222, Bulk Diesel Fuel, Commercial Grade Dedication

(2)

Item Number 00011420222, VAR Meter, Commercial Grade Dedication

(3)

Item Number 0005804562, Nuclear Instrument Module (NIM) Bin Assembly, Safety

Related Procurement

(4)

Item Number 00321979822, Flexible Hose, Commercial Grade Dedication

(5)

Item Number 14110020832, Counter Thrust Bearing, Safety Related Procurement

(6)

Item Number 139-A654012, Control Relay, Commercial Grade Dedication

(7)

Item Number 00321039641, Ball Valve, Safety Related Procurement

(8)

Item Number 932040051, Rotary Relay, Safety Related Procurement

(9)

Item Number 111-C03964, Molded Case Circuit Breaker, Commercial Grade

Dedication

INSPECTION RESULTS

No findings were identified.

EXIT MEETINGS AND DEBRIEFS

The inspectors verified no proprietary information was retained or documented in this report.

On September 24, 2025, the inspectors presented the design basis assurance

inspection (programs) inspection results to David Oertling and other members of the

licensee staff.

4

DOCUMENTS REVIEWED

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

ECC 92-025

Calculation Change Sheet

0

ECE 90-006

Emergency Diesel Generator Loading and Fuel Oil

Consumption

11

SA1047

Stress Analysis of Reactor Building Feedwater Piping -

Outside Containment

08

Calculations

SQ-MN-25

Valve Anchor Darling 20"

08

Corrective Action

Documents

Condition Report

(CR-WF3-)

2019-08482, 2019-08482, 2019-08903, 2021-02100,

2022-07017, 2023-13571, 2024-01460, 2024-02362,

2024-02363, 2024-02785, 2024-03099, 2025-00174,

2025-01000, 2025-01977, 2025-02145, 2025-02448

Corrective Action

Documents

Resulting from

Inspection

Condition Report

(CR-WF3-)

2025-04407, 2025-04261, 2025-04279, 2025-04252,

2025-04261, 2025-04328, 2025-04323, 2025-04407,

2025-04213, 2025-04279, 2025-04426, 2025-04455,

2025-04553, 2025-04555

5817-10206

2FW-V823A & 2FW-V824B Actuator Maintenance

Enhancement

01

5817-523 SH.2

20 Inch Feedwater Isolation Valve with 2FW-V823A &

2FW-V824B with A/DV Hydraulic Actuator

01

B430-23B.3R0,

B430-23B.2R1

Instrument Plate for Main Feedwater Isolation Valves

ESSE-FW602

Feedwater Isolation (FW184A) Accumulator Pressure

Switch Tubing

Drawings

SS-400-1-6STH

Male Connector Heavy Duty SAE

03/14/2008

EC-0000011723

Emergency Diesel Generator Limited Operating

Frequency

0

EC-0000094637

Storage and Use of Low Concentration Biodiesel Blends

in EDGs

0

WF3-EC-

0000083491

MFIV (FW-184A) Nitrogen Accumulator Leak - Change to

Flex Tubing to Reduce Vibration at the Nitrogen Pre-

Charge Fitting

09/22/2020

71111.21N.03

Engineering

Changes

WF3-EC-

0000084913

FW-184A Flex Tube - Planned FCR

05/24/2022

5

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

Procurement

Engineering

Evaluations (PE-

WF3-)

00108054, 00205295, 00205449, 00205578, 00206120,

00216385, 00217241, 00536211, 00549153, 00566283,

00566287

Quality Control

Inspection (QC-

WF3-)

00127596, 00151847, 00156703

Engineering

Evaluations

WF3-490224-001

ESFAS MDR Relay Evaluation

0

QUAL-E-017

Qualification of Potter Brumfield MDR Series Relays

3

Specifications

MS-01-107, MS-01-140, MS-01-180

Miscellaneous

WT-HQN-2024-

00258

Entergy Commercial Grade Item Survey Report of Saybolt

5/23/2025

CE-002-030

Maintaining Diesel Fuel Oil

38

EM-MP-101

Supply Chain Process

8

EM-MP-111

Inventory Control

19

EN-CY-122

Diesel Fuel Oil Program

9

EN-DC-306

Acceptance of Commercial-Grade Items/Services in

Safety-Related Applications

010

EN-DC-308

Safety and Quality Classification of Replacement Parts

8

EN-DC-313

Procurement Engineering Process

023

EN-DC-313-02

Procurement Engineering - Technical Evaluation of

Replacement Parts

008

EN-LI-108-01

10 CFR 21 Evaluations and Reporting

16

EN-MP-112

Shelf Life Program

011

EN-MP-117

Standardized Materials and Item Purchasing Process

15

EN-MP-120

Material Receipt

23

EN-MP-125

Control of Material

21

Procedures

EN-OE-100

Operating Experience Program

37

Purchase Orders

(PO-WF3-)

10356552, 10620937, 10664937

Shipping Records

Receipts

5818653, 6622543, 6732836, 6837967, 6939438,

10557929

Work Orders

WO- 00547982, 00575629, 00584408, 52901470, 52965525,

54125083, 54158891, 54163201, 54163202

6