Evinci Principal Design Criteria Topical Report Final Safety Evaluation Cover Letter
ML24283A136
Person / Time
Site: 99902079
Issue date: 10/16/2024
From: John Segala
NRC/NRR/DANU/UAL2
To: Schoedel A
Westinghouse
References
EPID L-2023-TOP-0040
Download: ML24283A136 (1)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 October 16, 2024 Mr. Anthony Schoedel, Manager Advanced Reactors Licensing Engineering Westinghouse Electric Company, LLC.

51 Bridge Street Pittsburgh, PA 15223

SUBJECT:

WESTINGHOUSE ELECTRIC COMPANY, LLC. - FINAL SAFETY EVALUATION FOR TOPICAL REPORT EVR-LIC-001-P/NP, WESTINGHOUSE PRINCIPAL DESIGN CRITERIA TOPICAL REPORT FOR THE EVINCITM MICROREACTOR (EPID: L-2023-TOP-0040)

Dear Mr. Schoedel:

By letter dated June 28, 2023 (Agencywide Documents Access and Management System, Accession Number, ML23179A196), Westinghouse Electric Company, LLC. (WEC) submitted the EVR-LIC-RL-001-P/NP, Principal Design Criteria [PDC] Topical Report [(TR)], Revision 0, for the U.S. Nuclear Regulatory Commission (NRC) staffs review of the safety evaluation (SE).

By email dated August 15, 2023 (ML23226A275), the NRC staff accepted the subject TRs for review. On September 15, 2023 (ML23271A068) and October 31, 2023 (ML23331A266), the NRC staff held clarification meetings support the review and development of the SE. By email dated November 16, 2023 (ML23325A036), the NRC staff issued requests for additional information (RAIs) to WEC. By letter dated May 15, 2024 (ML24137A080), WEC submitted Revision 1 of the eVinciTM Microreactor PDC incorporating changes from the clarification meetings and RAI responses.

The NRC staff's final SE for the TR is enclosed. Enclosure 1 is the redacted version of the SE and will be made publicly available. Enclosure 2, contains proprietary information and access to this document will be controlled consistent with the regulations in Title 10 of the Code of Federal Regulations, section 2.390, Public inspections, exemptions, requests for withholding.

The NRC staff concluded that that WEC developed a sufficient set of PDCs that are appropriate for establishing requirements for the eVinciTM Microreactor design. The subject TR is therefore suitable for referencing in future licensing applications for the eVinciTM Microreactor, subject to the limitations and conditions included in section 4.0, Limitations and Conditions, of the SE.

The NRC staff requests that WEC submit an accepted proprietary and non-proprietary version of the PDC TR within 3 months of receipt of this letter. The accepted version shall incorporate this letter and the enclosed SE.

to this letter contains proprietary information. When separated from the Enclosure, this letter is DECONTROLLED.

If you have any questions regarding this matter, please contact Patrick Boyle at (301) 415-3936 or via email at patrick.boyle@nrc.gov.

Sincerely, John Segala, Chief Advanced Reactor Licensing Branch 2 Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation Project No.: 99902079

Enclosures:

As stated cc: Westinghouse eVinci GovDelivery schoedaj@westinghouse.com John P. Segala Digitally signed by John P.

Segala Date: 2024.10.16 11:28:23

-04'00'

Package: ML24283A133 Letter: ML24283A136 : ML24283A137 : ML24283A150 (Proprietary)

  • SE Only NRR-106 OFFICE NRR/DANU/UAL2:PM NRR/DANU/UAL2:LA NRR/DEX/UTB1:BC*

NAME PBoyle CSmith GOberson DATE 10/09/2024 10/10/2024 04/15/2024 OFFICE OGC*

NRR/DANU/UAL2:BC NAME MWoods JSegala DATE 07/26/2024 10/15/2024