From:

Lucieann Vechioli Feliciano To:

Schoedel, Anthony J; Spalding, Amanda J Cc:

Charles Moulton; Boyce Travis; Dan Beacon (He/Him); Greg Oberson (He/Him); Michael Wentzel

Subject:

Westinghouse Electric Company: Transmittal of Request for Additional Information in support of NRC staff review of the Principal Design Criteria Topical Report for the eVinci Microreactor Date:

Thursday, November 16, 2023 4:42:00 PM Attachments:

image001.png By letter dated June 28, 2023 (Agencywide Documents Access and Management System (ADAMS)

Accession Package No. ML23179A195), Westinghouse Electric Company (Westinghouse) submitted topical report EVR-LIC-RL-001-P/NP, Principal Design Criteria, for U.S. Nuclear Regulatory Commission (NRC) staff review.

The NRC staff reviewed the report and held clarification calls with Westinghouse on September 15 and October 31, 2023. Based on the review and discussions, the NRC staff has identified that additional information regarding how Westinghouse intends to address fire protection requirements is needed to complete the review. On November 14, 2023, I placed an electronic version of the Request for Additional Information (RAI) in the box.com folder. The NRC staff and Westinghouse representatives discussed the RAI on a clarification call held on November 16, 2023.

The NRC staff request a response along with identifying any proprietary information by December 20th, 2023.

If you would like to discuss or need additional time to provide the responses to the RAI, please do not hesitate to contact me.

This email will be placed in ADAMS and will be declared public.

Thank you, Docket: 99902079 EPID: L-2023-TOP-0040

Lucieann Vechioli Feliciano (She, Her, Hers)

Project Manager NRR/DANU/UAL2 U.S. Nuclear Regulatory Commission Phone: 301-415-6035