ATTACHMENT 1 FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE 1, ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE TABLE 2, ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE

FORM OAR-1 OWNER'S ACTIVITY REPORT A1R24 Report Number ------------------------------------------------

Plant ______________

B_ra_id_w_o_o_d_G_e_ne_r_a_ti_ng.:..._S_ta_t_io_n_, _35_1_0_0_I_L_-5_3_,_s_u_it_e_8_4_, _B_ra_c_e_v_ill_e_, _IL_6_0_4_0_7 _________ _

Unit No. ______________ Commercial servicedate (1f applicable)

July 29, 1988

____________ Refueling outage no.

Applicable inspection interval Fourth ISi Interval, Third CISI Interval Applicable inspection period Edition and Addenda of Section XI applicable to the inspection plans Date and revision of inspection plans (1st 2nd 3rd 4th other)

Second Inspection Period (1st 2nd 3rd)

ASME Sec XI 2013 Edition, No Addenda Revision 1 March 20, 2024 A1R24 Edition and Addenda of Section XI applicable to repair/replacement activities, if different than the inspection plans 2013 Ed, No Addenda Code Cases used for inspection and evaluation:

Remarks N-532-5, N-513-4, N-729-6, N-722-1, N-885, N-770-5, N-578-1, N-805, N-648-2, N-864 (1f applicable)

CERTIFICATE OF CONFORMANCE I certify that (a) the statements made 111 this report are correct: (b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI and (c) the repair/replacement activities and evaluations supporting the completion of _______

A_1_R_2_4 ______ ~conform to the requirements of the ASME Code.Section XI (re(uel;ng outage number)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Hartford CT have inspected the items described in this Owner's Activity Report and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of the ASME Code.Section XI.

By signing this certificate. neither the Inspector nor the lnspector"s employer makes any warranty, expressed or implied, concerning the repair/re-placement activities and evaluations described in this report. Furthermore, neither the Inspector nor the Inspector's employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection Ste,eo Aod~,,&kc::::_ '-/'

(l11speclors Signature)

Commission NB15305 N I R (Nal1ona! Board Number and Endorsement)

Date l_)_,4()(7 2.o2Jf (07/23)

FORM OAR-1 OWNER'S ACTIVITY REPORT (Cont'd)

Table 1 Items With Flaws or Relevant Conditions That Required Evaluation for Continued Service Examination Category Item and Flaw or Relevant and Item Number Condition Description Evaluation Description D-B, A01SX-000011-M04-01A 1 SX25AA-6" through-wall leak (see IR EC 638242 - Affected components and 04546554) f nes are operable so long as EC and N-513-4 are complied with.

D-8, A01 SX-000011-M04-01 A 1SX27DA-10" through-wall leak (see IR l,Ec 638358 - Affected components and 04550393)

!lines are operable so long as EC and N-513-4 are complied with.

Code Class 3

3 (07/15)

FORM OAR-1 OWNER'S ACTIVITY REPORT (Cont'd)

Item Description 1SX25AA-6" 1 SX27DA-1 0" Table 2 Abstract of Repair/Replacement Activities Required for Continued Service Description of Work Date Completed Replace pipe and elbows due to through-wall 4/20/2024 leak and MIC (IR 04546554)

Replace flange, elbow, and pipe due to through-9/28/2023 wall leak and MIC (see IR 04550393)

Repair/Replacement Plan Number 1-23-024 (WO 04815840-01 }

1-23-003 (WO 5331156-03)