UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 July 30, 2024 NOTICE OF MEETING Organization:
HOLTEC INTERNATIONAL (HOLTEC)
Date and Time:
August 26, 2024, 1:00 p.m. - 2:30 p.m. (EST)
Location:
By videoconference
Purpose:
Pre-application Meeting for the Model No. HI-STAR 80 Package (agenda enclosed).
Participants:
NRC/NMSS/DFM HOLTEC Pierre Saverot, et al.
Khalil Wise, et al.
Meeting Category:
This is an Observation Meeting. The public is invited to observe this meeting and will have one or more opportunities to communicate with the NRC after the business portion, but before the meeting is adjourned. The NRCs Policy Statement, Enhancing Public Participation on NRC Meetings, effective May 28, 2002, applies to this meeting. The policy statement may be found on the NRC website, www.nrc.gov, and contains information regarding visitors and security.
Because this is a virtual meeting, please inform the NRCs meeting contact of your intention to participate by August 20, 2024. This step will ensure that the link for the Teams videoconference meeting will be provided to attendees participating virtually or by telephone.
Contact:
Pierre Saverot at pierre.saverot@nrc.gov Attendance at this meeting by other than those listed above should be made known by August 20, 2024, by email to the above contact with their full name, company/organization, and phone number.
Docket No.: 71-9374 EPID: L-2024-LLA-0096
Enclosure:
Agenda
ML24212A098 C=Without attachment/enclosure E=With attachment/enclosure N=No copy OFFICE NMSS/DFM E
NMSS/DFM NAME PSaverot SFigueroa DATE 07/30/2024 7/30/2024
Enclosure AGENDA Meeting between HOLTEC INTERNATIONAL and the U.S.
Nuclear Regulatory Commission August 26, 2024 1:00 p.m. - 2:30 p.m.
Public Session: 1:00 p.m. - 1:25 p.m.
- 1.
Introduction.
- 2.
Package Description.
- 3.
Summary of Proposed Changes for the HI-STAR 80 package.
- 4.
Acceptance Criteria Unique to this Amendment.
- 5.
Summary and Proposed Schedule.
- 6.
Questions from the Public.
Proprietary Session: 1:30 p.m. - 2:30 p.m.
- 1.
Review of Changes for the HI-STAR 80 package.
- 2.
Design Overview F-12P CBS Basket F-32B CBS Basket
- 3.
Structural Evaluation: Criteria and Modeling Methodology.
- 4.
Thermal Evaluation: Criteria and Modeling Methodology.
- 5.
Containment Evaluation.
- 6.
Shielding Evaluation.
- 7.
Licensing Schedule.
- 8.
Summary and Questions.