Letter Sequence Meeting |
|---|
EPID:L-2024-LLQ-0000, Supplement to Request for Approval of the Tennessee Valley Authority Nuclear Quality Assurance Program Description (Open) |
|
MONTHYEARML23254A0502023-12-12012 December 2023 Transmittal Letter and Safety Evaluation - Tennessee Valley Authority Quality Assurance Program Description, New Nuclear Program Project stage: Request ML24037A1442024-02-0505 February 2024 Clinch River Nuclear Site, Approved -A Version of the Quality Assurance Program Description for Tennessee Valley Authority (TVA) New Nuclear, Revision 2 Project stage: Request ML24184B9162024-07-10010 July 2024 U.S. NRC Meeting Slides for Meeting with Tennessee Valley Authority Regarding NRC Questions Regarding Scope of Nuclear Quality Assurance Program Project stage: Meeting ML24228A2312024-08-15015 August 2024 TVA Meeting Slides for August 19 Public Meeting Re QAPD Supplement Project stage: Meeting ML24221A0132024-08-19019 August 2024 July 10, 2024, Summary of Meeting with Tennessee Valley Authority Regarding a Proposed Change to the Tennessee Valley Authority Nuclear Quality Assurance Plan Project stage: Request ML24262A0602024-09-23023 September 2024 Summary of August 19, 2024, Meeting with Tennessee Valley Authority Regarding a Proposed Supplement to the Tennessee Valley Authority Nuclear Quality Assurance Plan Project stage: Meeting CNL-24-060, Supplement to Request for Approval of the Tennessee Valley Authority Nuclear Quality Assurance Program Description2024-09-24024 September 2024 Supplement to Request for Approval of the Tennessee Valley Authority Nuclear Quality Assurance Program Description Project stage: Request ML24269A0062024-10-0303 October 2024 Correction to Summary of August 19, 2024, Meeting with Tennessee Valley Authority Regarding a Proposed Supplement to the TVA Nuclear Quality Assurance Plan Project stage: Meeting ML24345A2262024-11-21021 November 2024 November 21, 2024-Draft Request for Additional Information - TVA Request for Approval of Revision 43 to TVA Fleet Quality Assurance Program Description Project stage: Draft RAI ML24346A0412024-12-10010 December 2024 NRR E-mail Capture - Request for Additional Information - TVA Request for Approval of Revision 43 to TVA Fleet Quality Assurance Program Description Project stage: RAI ML25002A1432024-12-30030 December 2024 Request for Additional Information - TVA Request for Approval of Revision 43 to TVA Fleet Quality Assurance Program Description Project stage: RAI PMNS20250070, Meeting with Tennessee Valley Authority to Discuss Changes to Organization and Impacts on the Nuclear Quality Assurance Program Under Review2025-01-27027 January 2025 Meeting with Tennessee Valley Authority to Discuss Changes to Organization and Impacts on the Nuclear Quality Assurance Program Under Review Project stage: Request ML25056A3722025-01-27027 January 2025, 10 March 2025 Summary of February 13, 2025, Meeting with Tennessee Valley Authority Regarding Recent Organization Changes and Impacts on the Tennessee Valley Authority Nuclear Quality Assurance Plan Project stage: Request CNL-25-010, Clinch River, Sequoyah, Units 1 and 2, Watts Bar, Units 1 and 2, Response to Request for Additional Information - TVA Request for Approval of Revision 43 to TVA Fleet Quality Assurance Program Description2025-02-26026 February 2025 Clinch River, Sequoyah, Units 1 and 2, Watts Bar, Units 1 and 2, Response to Request for Additional Information - TVA Request for Approval of Revision 43 to TVA Fleet Quality Assurance Program Description Project stage: Response to RAI ML25056A4202025-03-10010 March 2025 Summary of February 13, 2025, Meeting with Tennessee Valley Authority Regarding Recent Organization Changes and Impacts on the Tennessee Valley Authority Nuclear Quality Assurance Plan Project stage: Meeting ML25092A0552025-04-0101 April 2025 TVA Fleet - TVA Quality Assurance Program Description Second Round Request for Additional Information Project stage: RAI CNL-25-065, Second Round Request for Additional Information - TVA Request for Approval of Revision 44 to TVA Fleet Quality Assurance Program Description2025-04-14014 April 2025 Second Round Request for Additional Information - TVA Request for Approval of Revision 44 to TVA Fleet Quality Assurance Program Description Project stage: Request CNL-25-059, Nuclear Quality Assurance Plan, TVA-NQA-PLN-89A, Revision 432025-04-16016 April 2025 Nuclear Quality Assurance Plan, TVA-NQA-PLN-89A, Revision 43 Project stage: Request CNL-25-075, Revision to Second Round Request for Additional Information - TVA Request for Approval of Revision 44 to TVA Fleet Quality Assurance Program Description2025-05-0606 May 2025 Revision to Second Round Request for Additional Information - TVA Request for Approval of Revision 44 to TVA Fleet Quality Assurance Program Description Project stage: Request ML25149A0502025-05-30030 May 2025 Clinch River Early Site Permit; Sequoyah Nuclear Plant, Units 1 and 2; Watts Bar Nuclear Plant, Units 1 and 2 - Review of TVA Nuclear Quality Assurance Plan Project stage: Approval 2024-09-23
[Table View] |
Text
Meeting with Tennessee Valley Authority NRC Staff Questions regarding Scope of Nuclear Quality Assurance Program July 10, 2024 10:00 am - 11:00 am
Agenda
=
Background===
- Request for approval submitted April 1, 2024 (ML24093A47)
- Convert Quality Assurance Program Description for TVA Nuclear (TVA NQA-PLN89-A, Revision 43)
- Changes to Technical Specification 5.4 (Browns Ferry and Sequoyah) and 5.7.1 (Watts Bar)
- License Amendment Request portion accepted for review April 30, 2024 3
TVA Nuclear QAPD
- TVA NQA-PLN89-A, Revision 43
- Current format follows ANSI N45.2-1971, Quality Assurance Program Requirements for Nuclear Power Plants, and ANSI N18.7-1976, Administrative Controls and Quality Assurance for the Operational Phase of Nuclear Power Plants
- Convert to ASME NQA-1-2015, Quality Assurance Requirements for Nuclear Facility Applications 4
TVA Nuclear QAPD (continued)
- Provides description for operation of nuclear plant(s) at multiple sites, and the Clinch River Nuclear (CRN) Small Modular Reactor (SMR)
Project while under an approved early site permit (ESP)
- Applies to the TVA New Nuclear Program which addresses infrastructure and programmatic matters with siting, licensing, and planning for new nuclear projects 5
TVA Nuclear QAPD (continued)
- Site-selection, design, construction, and operation of new TVA nuclear plants (including the CRN SMR Project after issuance of the Construction Permit) are addressed under the TVA New Nuclear QA Program Description 6
TVA New Nuclear QAPD
- NNP-TR-001-NP, Revision 2, Quality Assurance Program Description for Tennessee Valley Authority (TVA) New Nuclear (ML24037A144)
TVA New Nuclear QAPD (continued)
- Provides a description of the TVA New Nuclear QAP for the site-selection, design, construction, and operation of nuclear plant(s) at multiple sites and projects.
- TVA New Nuclear organization is divided into two groups:
New Nuclear Program group and New Nuclear Projects group.
- New Nuclear Program group addresses site characterization, advanced design engineering, fabrication licensing, supply chain, and planning for multiple new nuclear projects across multiple sites.
- New Nuclear Projects group supports engineering, procurement, construction, startup, and operational development of specific projects at designated sites.
8
TVA New Nuclear QAPD (continued)
- The ESP for CRN SMR Project was produced under TVA-NQA-PLN89-A, Revision 39, and is excluded from compliance with NNP-TR-001-NP, Revision 2.
- ESPs for future SMR projects will comply with NNP-TR-001-NP.
9
NRC Questions
- 1. Does the TVA New Nuclear QAPD or QAPD for TVA Nuclear govern the activities performed by TVA New Nuclear Programs?
- 2. What is meant by statement in both QAPDs and operation of nuclear plant(s) at multiple sites?
- 3. Which aspects of the CRN SMR are covered by TVA NQA-PLN89-A, and which aspects are covered by NNP-TR-001-NP?