IINNDDIIAANNAA M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision: 16.5 Table: 14.3.6-17 Page:

1 of 2 UNIT 2 CONTAINMENT REGION DESIGNATIONS/IGNITER ASSEMBLY LOCATIONS Region Train A Compartment/Area-Elev.

No.

Region Train B Compartment/Area-Elev.

No.

1 Upper Volume Dome Area -760' A-29 1

Upper Volume Dome Area -760' B-29 1

Upper Volume Dome Area -760' A-30 1

Upper Volume Dome Area -760' B-30 1

Upper Volume Dome Area -760' A-31 1

Upper Volume Dome Area -760' B-31 2

Upper Volume Dome Area -748' A-32 2

Upper Volume Dome Area -748' B-32 2

Upper Volume Dome Area -748' A-33 2

Upper Volume Dome Area -748' B-33 2

Upper Volume Dome Area -748' A-34 2

Upper Volume Dome Area -748' B-34 3

Ice Cond. Upper Plenum-708' A-1 3

Ice Cond. Upper Plenum-709' B-1 3

Ice Cond. Upper Plenum-709' A-2 3

Ice Cond. Upper Plenum-709' B-2 4

Ice Cond. Upper Plenum-709' A-3 4

Ice Cond. Upper Plenum-709' B-3 4

Ice Cond. Upper Plenum-709' A-4 4

Ice Cond. Upper Plenum-709' B-4 4

Ice Cond. Upper Plenum-709' A-5 4

Ice Cond. Upper Plenum-709' B-5 5

Ice Cond. Upper Plenum-710' A-6 5

Ice Cond. Upper Plenum-709' B-6 5

Ice Cond. Upper Plenum-709' A-7 5

Ice Cond. Upper Plenum-709' B-7 6

Outside #2 SG Enclosure-662' A-14 6

Outside #2 SG Enclosure-659' B-14 6

Outside #3 SG Enclosure-662' A-15 6

Outside #3 SG Enclosure-659' B-15 7

Outside #1 SG Enclosure-659' A-13 7

Outside #1 SG Enclosure-662' B-13 7

Outside #4 SG Enclosure-662' A-16 7

Outside #4 SG Enclosure-659' B-16 7

Outside PZR Enclosure-662' A-17 7

Outside PZR Enclosure-659' B-17 8

East Fan/Accumulator Room-631' A-24 8

East Fan/Accumulator Room-630' B-24 8

East Fan/Accumulator Room-629' A-25 8

East Fan/Accumulator Room-629' B-25 9

West Fan/Accumulator Room-629' A-26 9

West Fan/Accumulator Room-623' B-26 9

West Fan/Accumulator Room-634' A-27 9

West Fan/Accumulator Room-634' B-27 10 Instrument Room-620' A-35 10 Instrument Room-620' B-35 11 Primary Shield Wall-647' A-18 11 Primary Shield Wall-642' B-18 11 Primary Shield Wall-648' A-19 11 Primary Shield Wall-637' B-19 11 Primary Shield Wall-648' A-20 11 Primary Shield Wall-636' B-20 11 Primary Shield Wall-648' A-21 11 Primary Shield Wall-636' B-21 11 Primary Shield Wall-641' A-22 11 Primary Shield Wall-637' B-22 UFSAR Revision 32.0

IINNDDIIAANNAA M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision: 16.5 Table: 14.3.6-17 Page:

2 of 2 UNIT 2 Region Train A Compartment/Area-Elev.

No.

Region Train B Compartment/Area-Elev.

No.

11 Primary Shield Wall-648' A-23 11 Primary Shield Wall-645' B-23 12 Inside #1 SG Enclosure-686' A-8 12 Inside #1 SG Enclosure-686' B-8 13 Inside #2 SG Enclosure-686' A-9 13 Inside #2 SG Enclosure-686' B-9 14 Inside #3 SG Enclosure-686' A-10 14 Inside #3 SG Enclosure-686' B-10 15 Inside #4 SG Enclosure-686' A-11 15 Inside #4 SG Enclosure-685' B-11 16 Inside PZR Enclosure-686' A-12 16 Inside PZR Enclosure-682' B-12 17 Vicinity of PRT-618' A-28 17 Vicinity of PRT-618' B-28 Key:

SG - Steam Generator PZR - Pressurizer PRT - Pressurizer Relief Tank Note: The locations, igniter identification numbers, and containment region designations given are for Cook Nuclear Plant Unit 2 and are similar for Unit 1.

UFSAR Revision 32.0