Letter Sequence Other |
|---|
EPID:L-2023-TOP-0014, GE-Hitachi Nuclear Energy - NEDC-33926P/NEDO-33926, Revision 3, BWRX-300 Steel-Plate Composite Containment Vessel (Sccv) and Reactor Building (RB) Structural Design (Open) |
Results
Other: ML23219A022, ML23220A210, ML23220A211, ML23341A063, ML23341A064, ML24033A312, ML24227A557, ML24227A558, ML25022A028, ML25022A029, ML25022A052, ML25022A053, ML25140A019
|
MONTHYEARML23219A0222023-08-0909 August 2023 NRC 898 - Acceptance Determination for the BWRX-300 Containment Vessel and Reactor Building Structural Design LTR Project stage: Other ML23220A2102023-08-22022 August 2023 NRC 897 - Withholding Determination for the BWRX-300 Containment Vessel and Reactor Building Structural Design LTR Project stage: Other ML23220A2112023-08-23023 August 2023 Email: Withholding Determination Transmittal for the BWRX-300 Containment Vessel and Reactor Building Structural Design LTR Project stage: Other ML23341A0642023-12-11011 December 2023 NRC 898 - Acceptance Determination for the BWRX-300 Containment Vessel and Reactor Building Structural Design LTR Project stage: Other ML23341A0632023-12-11011 December 2023 Acceptance Determination Transmittal for the BWRX-300 Containment Vessel and Reactor Building Structural Design LTR Project stage: Other ML24033A3122024-02-0505 February 2024 Rev. 2, Updated NRC 898 - Acceptance Determination for the BWRX-300 Steel-Composite Containment Vessel and Reactor Building Structural Design LTR Project stage: Other ML24227A5572024-08-14014 August 2024 NRC 897 - Topical Report Withholding Determination Project stage: Other ML24227A5582024-08-15015 August 2024 Email: Topical Report Withholding Determination Transmittal Project stage: Other ML24338A1742024-12-0202 December 2024 GE-Hitachi Nuclear Energy - NEDC-33926P/NEDO-33926, Revision 3, BWRX-300 Steel-Plate Composite Containment Vessel (Sccv) and Reactor Building (RB) Structural Design Project stage: Request ML25022A0522025-01-28028 January 2025 NRC 898 - Additional Review for Rev. 3, BWRX-300 Steel-Composite Containment Vessel and Reactor Building Structural Design LTR Project stage: Other ML25022A0292025-01-28028 January 2025 NRC 897 - Withholding Determination for Rev. 3, GEH BWRX-300 Steel-Plate Composite Containment Vessel and Reactor Building Structural Design LTR Project stage: Other ML25022A0532025-01-28028 January 2025 NRC 898 Transmittal - Additional Review for Rev. 3, BWRX-300 Steel-Composite Containment Vessel and Reactor Building Structural Design LTR Project stage: Other ML25022A0282025-01-28028 January 2025 Topical Report Withholding Determination Transmittal for NEDC-33926P Revision 3 Project stage: Other ML25081A0032025-03-21021 March 2025 Supplement to NEDC-33926P/NEDO-33926, Revision 3, BWRX-330 Steel-Plate Composite Containment Vessel and Reactor Building Structural Design Project stage: Request ML25140A0192025-05-21021 May 2025 Audit Plan - Rev 3 Supplement, BWRX-300 Containment Vessel and Reactor Building Structural Design Topical Report Project stage: Other 2024-02-05
[Table View] |
Text
From:
Jordan Glisan To:
Wadkins, George (GE Power Portfolio)
Cc:
Diaz-Quiroz, Jesus G. (GE Power Portfolio); Michelle Hayes; Jim Shea; Ian Tseng; Allen Fetter
Subject:
Revised 898 for the BWRX-300 Steel-Composite Containment Vessel and Reactor Building Structural Design LTR Date:
Monday, December 11, 2023 11:21:00 AM Attachments:
Updated NRC 898 - Acceptance Determination for the BWRX-300 Steel-Composite Containment Vessel and Reactor Building Structural Design LTR.pdf Mr. George Wadkins Vice President New Power Plants and Product Licensing GE Hitachi Nuclear Energy
Mr. Wadkins,
By email transmittal (ML23220A017) dated August 9th, the U.S. Nuclear Regulatory Commission (USNRC) staff accepted the subject topical report. Attached to this email youll find the updated form for the USNRC staff topical report completeness determination for the submittal of GE-Hitachi BWRX-300 Steel-Plate Composite Containment Vessel (SCCV) and Reactor Building (RB) Structural Design. This updated form reflects the new RAI and Draft Safety Evaluation issuance dates due to the schedule adjustment. The schedule adjustment stems from a delay in receiving reference material and our agreement to extend the audit. This updated schedule remains dependent on several factors, such as the timeframe for resolution of technical issues, or other unanticipated factors.
If you have any questions, please let me know.
Docket No.: 99900003
Jordan Glisan Project Manager U.S. Nuclear Regulatory Commission NRR/DNRL/NLIB Phone: 301-415-3478