EXPORT LICENSE NRC FORM250 NRC LICENSE NO.: PXB234.01 United States of America Nuclear Regulatory Commission Washington, D.C. 20555 Page 1 of 3 NRC DOCKET NO.: 11006390 LICENSE EXPIRES: October 19, 2025 Pursuant to the Atomic Energy Act of 1954, as amended, and the regulations issued by the Nuclear Regulatory Commission (NRC) pursuant thereto, and in reliance on statements and representations heretofore made by the applicant/licensee, this license is hereby issued authorizing the licensee to export of the byproduct materials listed below, subject to the terms and conditions herein. This license is only valid if the licensee or 'Other Party (ies) to Export' maintain the requisite NRC or Agreement State domestic license(s).
LICENSEE Weatherford International LLC &
Subsidiaries & Affiliate Companies 2000 St. James Place Houston, TX 77056-4123 Attn: Jeff Pettigrew INTERMEDIATE CONSIGNEE(S) IN FOREIGN COUNTRY(IES)
See following page( s)
APPLICANTS
REFERENCE:
PAK2022 ULTIMATE CONSIGNEE(S) IN FOREIGN COUNTRY(IES)
(well logging)
OTHER U.S. PARTY(IES) TO EXPORT See following page(s)
ULTIMATE DESTINATION: Pakistan DESCRIPTIONS OF 10 CFR PART 110, APPENDIX P, BYPRODUCT MATERIALS TO BE EXPORTED, INCLUDING CONDITIONS AND NOTES (NOTE: SEE PAGE 2 FOR DEFINITIONS OF CATEGORY 1 AND CATEGORY 2)
Export of---.
and-. which may individually or combined aggregate to,,..,.,
a o
2 anities as well a. ~
for usein o~~~sauthorized. Tot~ntitiesare limitedto
-of
.-of
-.-of_,_..o,_._ of-
.and-of Sealed sources shall remain in the custody of either Weatherford International LLC & Affiliate Companies or an authorized ultimate foreign consignee at all times and when not in use, shall be stored in a secure facility controlled either by Weatherford International LLC & Subsidiaries & Affiliate Companies or an authorized ultimate foreign consignee.
Licensee is respons ble for compliance with all applicable export, and other domestic regulatory requirements, including all terms and conditions of domestic material possession licenses. The licensee, if not already submitted with its application, must submit pertinent information required by 10 CFR 110.32(d) and pertinent documentation required by 10 CFR 110.32(g) at least 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to shipment. See page 3 for Mandato,y Pre-Shipment Notifications.
Licensee shall submit by February 1 of each year one copy of a report of all americium shipments (under this license or under a general license) during the previous calendar year required by 10 CFR 11 0.54(b). The report must include: (1) a description of the material, including quantity; (2) approximate shipment dates; (3) a list of recipient countries, end users, and intended use keyed to the items shipped.
This license expiration date is based on established limits. This license replaces PXB234.00 and amends its authority by extending the date of expiration from December 13, 2022 to October 19, 2025.
Neither this license nor any right under this license shall be assigned or otherwise transferred in violation of the provisions of the Atomic Energy Act of 1954, as amended.
This license is subject to the right of recapture or control by Section 108 of the Atomic Energy Act of 1954, as amended, and to all the other provisions of said Acts, now or hereafter in effect and to all valid rules and regulations of the Nuclear Regulatory Commission.
THIS LICENSE IS INVALID UNLESS SIGNED BELOW BY AUTHORIZED NRC REPRESENTATIVE NAME AND TITLE:
DATE OF ISSUANCE:
Sabrina D. Atack, Deputy Director Office of International Programs October 19, 2023 EXPORT LICENSE
INTERMEDIATE CONSIGNEE(S) IN FOREIGN COUNTRY{IESl Continued:
- 1.
(freight forward/custom broker)
- 3.
(freight forward/custom broker)
OTHER U.S.PARTY(IES) TO EXPORT Continued:
- 1. Weatherford International LLC &
Subsidiaries & Affiliate Companies 7504 Benbrook Parkway Ft Worth, TX 76126 (well logging support services)
- 3. Weatherford International LLC &
Subsidiaries & Affiliate Companies 1040 Schlipf Road Katy, TX 77 493 (well logging support services)
- 2.
(freight forward/custom broker)
- 2. Weatherford International LLC &
Subsidiaries & Affiliate Companies 16210 West Hardy Road Houston, TX 77060 (well logging support services)
PXB234.01 Page 2 of 3
MANDATORY ADVANCED NOTIFICATIONS PER 10 CFR PART 110.50(c)
The following Advanced Notifications must be made to both the NRC and, in case of exports, the government of the importing country in advance of each shipment:
Mandatory Advanced Notifications to the NRC are to be emailed to hoo,hoc@nrc,goy (preferred method) or faxed to the NRC at 301-816-5151. In the subject line of the email or on the fax cover page include: "10 CFR 110.50(c)
Notification." For technical assistance, use the same e-mail address or call 301-287-9056.
Mandatory Advanced Notifications to the government of the importing country must be emailed or faxed to the appropriate foreign government authorities. To locate the point-of-contact for international Advanced Notifications see: bUP;llwww-ns jaea org(down1oads(rw(jmp-export1jmport-export-contact-pojnts pgt. In the subject line of the email or on the fax cover page include: "NOTIFICATION TO THE IMPORTING STATE PRIOR TO SHIPMENT OF CATEGORY 1 OR 2 RADIOACTIVE SOURCES." For technical assistance or for countries not listed, contact the Office of International Programs' exporVimport staff at 301-287-9056.
Jable 1; Appendjx e 1° Part 110 c ategory 1 and category 2 Radjoactjye Material Jbresb01d biroiJs Radioactive Category1 Category2 Material Terabequerels (TBq)
Curies (Ci)'
Terabequerels (TBq)
Curies(Ci)1 Americium-241 (Am-241) 60 1.~
0.6 16 Americium-241 /Beryflium (Am-60 1.60C 0.6 16 241/Be)
Califomium-252 (Cf-252) 20 o4l 02 5.4 Curium-244 (Cm-244) 50 1,40C 0.5 14 Cobalt-60 (Co-60) 30 81(
0.3 8.1 Cesium-1 37 (Cs-1 37) 100 2.7lA 1.0 27 Gadolinium-153 (Gd-153) 1,000 27,IJUI.
10.0 270 lridium-192 Clr-1 92) 80 2.7fI 0.8 22 Plutonium-238' (Pu-238}
60 1,6UC 0.6 16 Plutonium-23~1:lefY11iUITI" (PIJ..239/Be) 60 1,60C 0.6 16 Promethium-147(Pm-147) 40,000 1,100,000 400 11,000 Radium-2263 CRa-226) 40 1,1fI 0.4 11 Selenium-75 (Se-75) 200 5,4lA 2.0 54 stron ium-90 (Y-90) 1,000 27,IXX 10.0 270 Thulium-170 (Tm-170) 20,000 540,0lA.
200 5,400 Ytterbium-169 (Yb-169) 300 8,1 0C 3.0 81 Calculation of Shipments Containing Multiple Sources or Radionuclides:
The "sum of fractions" methodology for evaluating combinations of radionuclides being transported is to be used when import or export shipments contain multiple sources or multiple radionuclides. The threshold limit values used in a sum of the fractions calculation must be the metric values (i.e., TBq).
I. If multiple sources and/or multiple radionuclides are present in an import or export shipment, the sum of the fractions of the activity of each radionuclide must be determined to verify the shipment is less than the Category 1 or 2 limits of Table 1, as appropriate. If the calculated sum of the fractions ratio, using the following equation, is greater than or equal to 1.0, then the import or export shipment exceeds the threshold limits of Table 1 and the applicable security provisions of this part apply.
II. Use the equation below to calculate the sum of the fractions ratio by inserting the actual activity of the applicable radionuclides or of the individual sources (of the same radionuclides) in the numerator of the equation and the corresponding threshold activity limit from the Table 1 in the denominator of the equation. Ensure the numerator and denominator values are in the same units and all calculations must be performed using the TBq (i.e., metric) values of Table 1.
R1 = activity for radionuclides or source number 1 AR1 = activity limit for radionuclides or source number 1 R2 = activity for radionuclides or source number 2 AR2 = activity limit for radionuclides or source number 2 RN = activity for radionuclides or source number n ARN = activity limit for radionuclides or source number n
~ I R 1 R 2 Rn ]
L., l --+ --+ -
~ 1 1
AR I A R 2 ARn 1 The values to be used to determine whether a license is required are given in TBq. Curie (Ci) values are provided for practical usefulness only and are rounded after conversion.
2 The limits for exports of Pu-238 and Pu-239/Be can be found in § 110.21.
3 Discrete sources of Radium-226 PXB234.01 Page 3 of 3