Watts Bar Nuclear Plant September 12, 2023 Watts Bar Nuclear Plant (WBN)

Pre-submittal Meeting for License Amendment Request Modify the Watts Bar Nuclear Plant Unit 1 and Unit 2 Technical Specification Surveillance Requirement 3.9.5.1

Agenda

  • Introduction
  • System Description
  • Description of the Proposed Change
  • Reason for the Proposed Change
  • Technical Evaluation
  • Precedent
  • Schedule Milestones
  • Closing Remarks 2

Introduction

  • The purpose of this meeting is to discuss a proposed license amendment request (LAR) for WBN Units 1 and 2.

l 3

=

System Description===

  • Heat is removed from the RCS by circulating reactor coolant through the RHR heat exchangers, where the heat is transferred to the Component Cooling Water System. The coolant is then returned to the RCS via the RCS cold leg(s).
  • Portions of the RHRS also serve as parts of the emergency core cooling system (ECCS) during the injection and recirculation phases of a loss of coolant accident (LOCA). The RHRS is also used to transfer refueling water between the refueling cavity and the refueling water storage tank at the beginning and end of the refueling operations.

l 4

Description of the Proposed Change l 5

Reason for the Proposed Change

  • The proposed change to WBN Units 1 and 2 SR 3.9.5.1 incorporates a reduction in the minimum RHR flow requirement from 2,500 gpm to 2,000 gpm during refueling operations with high water level conditions (Mode 6 with the water level greater than or equal to 23 ft above the top of the reactor vessel flange).
  • The proposed change allows operation of the RHR system at reduced flow during refueling operations with high water level conditions and is consistent with similar RHR flow requirements in WBN Units 1 and 2 SR 3.9.6.1 and SQN SRs 3.9.5.1 and 3.9.6.1.

Technical Evaluation

  • The technical evaluation supporting the proposed change is provided in Westinghouse Electric Company LLC (Westinghouse) Letter Report, LTR-SEE-23-4-P, Revision 1, Technical Evaluation in Support of Watts Bar Units 1 & 2 Residual Heat Removal System (RHRS) Flow Rate Reduction During Mode 6 Operation at Refueling Water Level 23 Feet, which is a technical evaluation performed by Westinghouse to support the proposed change to WBN Units 1 and 2 SR 3.9.5.1, which will be discussed during the closed portion of the meeting.

l 7

Precedent l 8

  • The proposed change is similar to a license amendment for SQN Units 1 and 2 (ML013300379), which also approved a reduction in the RHR flowrate from 2,500 gpm to 2,000 gpm for all water levels.

Schedule Milestones l 9

  • TVA to submit LAR to NRC by September 30, 2023.
  • Request NRC approval within 1-year from submittal.
  • 30-day implementation following NRC approval.