96Zlt,t, TP.A1t-l A
~UZ§
~
0PfN
~
Xf'jl",'1°r FCV 41 MAIN STEAM No.1 ISOLVALVE - CIRCUI T N0.l0292SV0I; I01%SV0I VAi.V E CIP.C. UlT
~Ol,vtV.TIUo,l>Ji..
SOVILV.TIWNI!.
Sl"'LICE.
L.Ot.r,.,io.
- CDC, f'CV-1,1 MA.IN ST£Ar,q [SOL~ 11'10/211D X f tV41 i~~i~\t~'i 1'11
)(SV2'1l 1'lf>
X!.V1'18
~
EN"D:2.4"1
£iJD32."f a,t:>UG fCV 41 I
I 2 1 I 11,012110 XFC.V41 I~~~~~~~:
300 X!>VlOO 301
)(SV30 I f{.V43 I
I 3 I I ll'H>/3150 XFCV43 i~!6!;:~:
303 6 '1,SV303 304 6 Y,SV304 FC.V44 t
'f 4 f * !1'10/3150 X_FC.V44 !~;~~::i:
301, 6 )(~1,'30'-
! Ol 6 )(W301 f:::. TRANSIENT SURGE Sl./pt>/(ESSOR REMOV&D I
.SA CNV !ca
~--ILl)---,Nl~Nl---o'=_jc,c=~---~
FCV 25 STE.AMG£N. 2-I MAIN !SOL. BY.PASS VALVE CKT NO I0/88SV0I OTHER MAIIJ ISOLATION BYPASS VALVe.$ SIMtLAl'f E)(CEf"r AS -SHOWN ON TABLE VALVE DESCRIPTION DC CIRCUIT SOL£NOID VI\LV= VALVE PaS MAINSTCl'tM UH& /SOL.
NP CKTH'i N*
NO LOC.
CLOSE;] OPEN Dvtce Loe. !CONTACT fCV2S SGZ:I MAJ!J !SOL 8 119D I0188SVOI 1ee I~ 18.!3 I 188 Kblb I ~
I~~~ -~
FCV24 SGz.2 MAIN /SOL Bffl'\SS 2.17D IOl87SVOJ 187 I XS!/18 7 187 I 18G K,16 --
FCV2J SGl*J MAIN JSOL BY.PASS 2I 7D IOIBG-SVOI 18* =
JBS 184 K,2.3 !N1£ 1'!41-'.:¢5381,~
POS 11:Z I, A::>S litt, F'<.IS b2..5, ~s 826 LOC.~l-~,XP,!!Sli23,~SBt.S KEY owe.
SEC TI ON_5 _
IO TAB LE OF DEVICES FUNLl l ON TYPE IT/OWC.,IJ ff! /fl) l$F'M" JltiNAl SV SOll<tJOIO VALVES t*n,2qa
- 8)
TACTSOPE '1 0URl~Tes (8)
PUSH!07£ST
- 2. MAIN STEAM ISOLATION VAL',ES AAE ATO/ FAIL C~D, SOLENOID \/ALVES AFle ENERGIZED 1'.0 V&IT, CLOSING JSOI.ATI0H Vi'lt.VES. (ATO= AIR. "TO OPEN)
~ TOl!,EREQU1PMfNf~scocl.TION NU~~BERS
~
COl*.ffA.OL BOl>..A.O
({H<C[N:!,ATf" f f£t;owAnlt.l 2VB31
~~
NUlLE A.P. !:!AfEC.UA.A.O OUTPUf FlAlK 'A~
X.fCV41 -
f LOW C.OtJTFlOL VALVE FCV41 ( AIR OPtRATEO)
RNS TA NUCLEAR SAFEGI.VIRO TEST RAC"-
TR-'I IN A C,NC2 -
- - - CONTROL BMRO REACTOR COOLANT
~- -
CONTROL 80,',RO Cl.EM/CAI.. 2. VOLUME CONTROL an1110 -
- -* TERMINAL 80K AREA H N'l 1/0 REFERENCE DRAW INGS
- 1. DESCRI PTION Of ELECT. SUHIIIAfll DIAC,~A"" 5YNBOlS AIJO l!A.(.UIT DE:!.IC.IJ"'-T I 0' -
owe., o,;0003
- 2. EQ.UIPMO:,,Jf L0(4TION NUll\ 0 [RS --- ----
owc.. /OJ (J/J 3
PIPl~G. SlHt"-\A.T!l -
TU!'ll!.INE foTEAM $()PPL'( sys,- OwG,108 00 4 4
IIJ5.T"'.()M£NT 5.CIIEM AHC. -
f lOW I NHIWMOJT ~YS.. -
OW(i. \08011
- s. S.11>1GU lll<IE MUER,i.n... Y DI"'
- ilSVCC SYSTEM -
owc., 44it40
- 6. MAIN ST[AM VALVf -
- --- - -- - RH. U30~9 7.@.UNC.Ti,'.JN OIAC,IIAM~---------- RE C..
tlb3J95 8.@.SOLID 5TArE. PROTE.GTION SYHf.M-- ---
RE.C..
663Z.31
- 5. 5::HE.i-1ATIC. OIAC,RA~ M/.11' At;h()N(.!ArQ/1' ~M.UTIJ --- D*!ti, 5 00718 10-SCMEMATIC DIAGRAM MONITOR LIGHT BOX O OWG. 44 / 455
//
Bwo:: 0/AG.
- ERFDSANPTECH. SUPPDRT cumR _
__ C,wG 445297 It. 5CHEU. O!AG. 55P5 OUTPUT RELAYS, TRAIN A, TRAIN f, _
DWG5 503089. S03093 NUCLEAR SAFETY RELATED VA L VE NOS:
FCV 25, 24, 23, 22, 4 1, 42, 43, 44 UNIT 2 SCHEMATI C DIAGRAM MA IN STEAM ISOLATI ON VALVES