7 to Updated Final Safety Analysis Report, Chapter 7, Figure 7.2-1, Drawing 495841, Sheet 1, Functional Logic Diagram Index & Symbols
ML23241A427
Person / Time
Site: Diablo Canyon  
Issue date: 05/25/2023
From:
Pacific Gas & Electric Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML23241A052 List: ... further results
References
DCL-23-044
Download: ML23241A427 (1)


Text

1 v8S6v,

LOGIC SY MBOLS SYMBOL LOGIC FUNCTION y

A DEVICE WHICH PRODUCES AN OUTPUT ONLY WHEN EVERY INPUT EXISTS.

+

AOEVlCEWHICHPROOUCESANOUTPUTONLY WHEN THE INPUT DOES NOT fXJST.

~

A 0EVJCEWHJCHPR00UCESAN0UTPUT WHEN ONE INPUT (QR MORE ) EXISTS.

~

OFF RETURN ADEVlCEWHlCHRETAINSTHECONOlT!ONOF' MEMORY OUTPUT CORRESPONDING TO THE LAST ENERGIZED INPUT, EXCEPTUPONJNTERRUPT!ONOFPOWER IT RETURNS TO THE Off CONO!T!ON.

~

RETENTIVE A DEVICE WHICH RETAINS THE CONOlTION OF MEMORY OUTPUTCORRESPONDINGTOTHE LASTENERGIZEO INPUT (ALSO UPON I NTERRUPTION OF POWER).

~

ADJUSTABLE A DEVICE WM!Cfl PRODUCES AN OUTPUT TI ME DELAY FOLLOWING DEF INITE INTENTIONAL TJME ENERGIZING DELAY AFTER RECEIVING Ml INPUT.

tjx ADJUSTABLE AOEV1CEWH1CHCONTINUES TOPRODUCEAN TIME DELAY OUTPUT FOR A DEFINITE INTENT IONAL PERIOD C

DE - ENERGIZING OF TIME AFTER THE INPUT HAS BEEN REMOVED.

1$1 COINCIDENCE A DEVICE WHICH PRODUCES AN OUT PUT

!20UTOFJSHO',/Nl

',/HEN THE PRESCRIBED NUMBER OF INPUT S EXIST (EXAMPLE 2 INPUTS ~ST EXIST FOR AN OUTPUT J.

~

MS RETENTIVE ADEVICEHAVINGTHELOG!CAL FUNCTION MEMORY AS INDlCATED BYTHEDlAGRAMBELOW,

WITH MANUAL RESET ACTUA TI NG MANUA L RESET SIGNAL (MOMENTARY P.B.)

ADDITIONAL SYMBOLS

~

NSTRUHEflT CHANNEL BISTABLE ; A TAG NOTATION OF

  • -.* I NDICATES A GENERIC BISTABLE ASSOCIATED WITH A GEflERIC OR TYPICAL FUNCTION BLOCK INDICATES THAT THE DEVICE OR INSTRUMENT CHANNEL HAS A BISTABL E LOGIC
  • t
  • OUTPUT WHEN :

J PARAME TE:R MEASURED rs GREATER THAN A PRESET VALUE 1

PARAHETER MEASURED IS LESS HIAN A PRESET VALUE U

A~~~nfRA~~~¥~ED DEVIATES FROM A PRESET VUUE BY MORE HlAN

-=\::::F-oR+oR +

SAMEASABOVEEXCEPTWITHANAUTOMATICALLYSET VAR[ABLEVALUE U

OR J OR l

~~~ET~i/~n~ EXCEPT WITH REQUIRED HYnERES I S BETWEHI TURN ON

.,,,,,- NON - I NSTRUHENTBISTABLE 9~

ou,eu, 1<01CH0< 5'ME,s rnc.1,rn "°

& 2 0

CD ANALOG INPUT CONTR0Lr1-,ANALOG ie~i~----u GATE ANALOG OUTPUT ALARM ANNUNC I ATOR I ALARMS ON THE SAHE SHEET WITH THE SAME SUBSCRIPT SHARE A COMMON ANNUNCIATOR WINDOW)

COMPUTER INPUT INDICATOR LAMP T

TRIP STil.TUS LIGHTS P

PERMISSIVE ST ATUS LIGHTS B

BYPASS STA TUS L IGHTS A

ACTUAT ION SIGNAL LIGHTS LOGIC INFORMATION TRANSMISSION A ALOG INFORMATION TRANSMISSION :

AL VARIABLE FOR O!GITA L SYSTEM ANALOG DISPLAY I

ANALOG INDICATOR R

RECORDER R2 RECORDER 2 CliMINEL RJ RECOROER3CHANNEL R8 RECORDER 8 POINT AOEV!CE WHICHPERHITSANANALOGSIGNAL TO PASS IN AN ISOLA TE CIRCUIT IF THE CONTROL LOG I C INPUT EXISTS.

--- ~

SIGNAL MULT IPLICA T ION WFUNC TJONC

  • A* B I

C 0~

~ /* 1 LOG!CACTUATEOSWITCH!NG FUNCTIONC

  • B IF O*I C*A I F 0
  • 0 C
  • -~"I" f - -~- '"""1'" """"

l_

B* f ! A l DEV I CE FUNCT ION LETTERS AND NUMBERS DC

>C PC SC 20 27 POSITION !DISPLACEMENT) CHANNEL FLOW CHANNEL LEVEL CHANNEL NUCLEAR CHANNEL PRESSURE CHANNEL RADIATION CHANNEL TEMPERATURE CHANNEL ELECTRIC OPERATED VALVE UNOERVOLTAGERELAY POSITION SWITCH SUFFI X LETTER :

cc, oo, be, bo - LIMIT SWI TCH to, to,

TORQUE SWITCH 010;,;

b 101/4 POSITION SWITCH DEVELOPMENTS FULL TR AVEL r

..l..---.. -

AC CIRCUIT BREAKER SUFFIX LETTER :

PRESSURE SWITCH LEVEL SWITCH FLOWSW] TCH UNOERFREOUENCY RELAY AUKILIARY CONTACT -

OPEN WHEN MAIN CONTACTS ARE OPEN AUXILIARY CONTACT -

CLOSED WHEN MAIN CONTACTS ARE OPEN NOT ES I. EXCEPT WHERE I NDICATED OTHERWISE THE FOLLOWING JS TRUE :

All LOGIC CIRCUITS ARE REDUNDANT. ALL INSTRUMENT CHANNELS, B!STABLES, ANNUNCIA TORS, COMPUTER INPUTS, ANO INDICATOR LAMPS ARE NOT REDUNDANT. MANUAL CONTROL 00 NOT HAVE REDUNDAN T ACT UATORS, BUT 00 HAVE REDUNDANT CONTACTS WHERE LOGIC !S REDUNDANT.

ALL INDICATOR LAMPS, COMPUTER INPUTS & ANNUNCIATORS ARE CONNEC TED TO BOTH TRAINS SO THAT A SIGNAL I N EITHER TRAI N WILL ACTUATE.

2. THIS SET OF DRAWINGS IS IDENTICAL FOR UNITS I & 2 EXCEPT FOR Tt,E TAC NUMBERS.

FOR UNIT I, TAG NUMBERS ADD A

  • I *. EXAMPL E; IPC-SSE FOR UN!T 2. TAG NUMBERS ADD A " 2 ". EXAMPLE :

2PC-55 E

3. WHENEVER A PROCESS SIGNA L IS USED FOR CONTROL ANO IS OER!VED FROH A PROTECTION CHANNEL,

ISOLAT I ON HUST BE PROVIDED.

. THIS DRAWI NG I L LUSTRATES THE FUNCTIONAL REQUIREMENTS OF THE REACTOR CONTROL AND PROTECTION SYSTEM. THIS DRAWING DOES NOT REPRESENT ACTUAL HARDWARE

~MENTA T !ON.FOR HAROWAREIHPLEMENTATION.REFERTOTHEAPPL ICABLESCHEMAT[C.

L---

NUMBERSREFERTOTHEREFERENCENUHBERS ~

10 WE DWG PG&E DWG FUNCTIONAL LOG!C DIAGRAM INDEX AND SYl-llOlS __

_ ____ ___ ____ ____ 5653014-1 __ __ __ 495841 FUNCTIONAL LOGICDIAGRAHREACTO!lTRIPSICNALS_

_ __ 56530 74

  • L ----- 95M2 FUNCTIONAL LOG IC DIAGRAM NUCL EAR INSTR AND MANUAL TR I P S1GNALS. _____ ___ __ __ ____ _ 56530H ___ __ 49s8 3 FUNCTIONAL LOGIC DIAGRAM NUCLHR IN>>TR PERMISSIVE$ ANO BLOC~S. __________________ 5653074-4 ______ 495844 FUNCTIONAL LOGIC OUCRAMPRIH.1.RY COOLANT SYSTEM TRIP SIGNALS..

___ 5653074

  • 5 __ ___ _ 495845 6. FUNCTIONAL LOGICOIAGRAI-IPRESSL.RIZER TRIP SIGNALS, __________________ ____ __ __ ___ 5653DH
  • 6 __

___ 495846 FUNCTIONAL LOGIC DIAGRAM STEAM GENERATOR TRI P SIGNALS ___

_ ______ ______ ____ $653074-7 __ ___ _ 495847 FUNCTIONAL LOGIC OIAGRAI-ISAFEGUAROS ACTUATIONSIGNALS

_____ _____ ___ _ 56530H -s ______ 495848

9. FUNCTIONAL LOGIC DI AGRAMROOCONTROLSANOROOBLOCKS ______________________ _____ 5653DH - 9_ __ ___ 495849
10. FUNCTIONAL LOGIC DIAGRAM STEAM OUW CONTROL

____ _______ _______ __ 5653D74-I 0 *

  • ___ ~95850 I I.FUNCT JONALLOGJCD IAGRAMPRESSURI ZERPRESSUREANDLEVElCONTRQl__

_ _____ S6S3074 -l l ___ __ 9585 I

12. FUNCTIONAL LOGIC O!AGAAH PRESSURIZER MEATER CONTROL

_ __ 5653D14 - I2 ___ __ 495852

13. FUNCTIONAL lOG!C D!AGRAMFEEO\/ATERCONTROL AND ISOLATION ___ ___ ________ ________ 565307 4-13_ ____ 495853 I4.

FUNCT!ONALLOGICD!AGRAMF[EO\/ATERCONTROL ANDISOLATJON.__

_ _______ ___ _ 5653074-14 __ ___ 95854

15. FUNCTIONAL LOGIC DIAGRAM AUX I LIARY F'EEOWUER PLM'S STAATLP _____________ ________ 56530H
  • l5 __ __ _ 95BS5
16. FUNC TIONAL LOG I C DIAGRAM TURBINE TRIPS, RUNBACKS 1. SIGNALS. ___________ __________ 5653D74-I6 ___ __ 95856
17. F'UNCTIONAl LOGIC OIAGRAH AMSAC SIGNALS_

_ ___________ 56530H-I 7_ ____ 4958S7

18. FUNCTIONAL LOGIC OlAGRAHSE I SM l C TRIP, _____________ ____________ __ __ __

________ 8759077 _______

95858

19. FUNCTIONAL LOGI C DIAGRAM DIGI TAL n1 CONT SYS INPUT SIGNAL H Ll OATJON ___________ _ 565307 -

1 8 ___ __ 495859 20. FUNCTIONAL LOGIC OUGRAI-I DIGITAL FIi CONT SYS FW FLOII CONTROLLER 1. C,, OEMANQ ______ 56530H -I 9_ ____ 495860 2 1. FUNCTIONAL LOGIC OIAGRM-1 DIGITAL F'II CONT SYS CONT vcv SEO 1. TRACKING ux;1c_ ___ ___ 56530H - 2o __ ___ 49586 I 22. FUNCTIONAL LOGIC OUGRAI-IOIGITAL fll CONT SYS SI GNAL SELECTOR LOGIC _____________ 5653DH - 2I ___ 495862

23. ORAi/iNG !~DEX SOLID STATE PROTECTION SYS INTERCONNECT!O'I L SCHEM. DI AGRAM ___ __ _ __ 1080442 -- - 458826 NUCLEAR SAFETY RELATED KEY OWG--SEC TI ON _l_

UNIT I FUNCTIONAL LOGIC DI AGRAM INDEX AND SYl-'60LS PACIFIC GAS ANO ELECTRIC COMPANY SANFRANCISCO, CALIFORNIA RM U<IDEXEO REV_!_

COAST VAUOSOIVISIOH 495841 j 10 U2 -

495871