SAFETY ANALYSIS REPORT Revision 50a
Table of Contents Safety Analysis Report Page-i Rev 5050 Summary of Changes Rev 5050a Issue /
Date Change Description of Change 50 LBDCR-22-016 GCP-073:
SAR Section 1.1.3.2, pg 1.1-7, 1.1 Removed references to various Production Phases of Operations in Chapter 12, AC 171129: Updated SAR Section 1.3.2.3, pg 1.3-4 with Covenant Health Hobbs Hospital name change and updated the bed count from 250 to 99 AC 168390 - Updated SAR Section 1.2.1.2, pg 1.2-11 to state "The President and Chief Executive Officer" for consistency Corrected minor issues with SAR 5.6-7, pgs 5.6-7/10/11 tables (blue text and have inconsistent fonts)
AC 170888 - Updated SAR Section 8, pg 8.0-1 to indicate that the MOU files are kept by the Safety and Emergency Response Manager.
AC 170838: SAR Section 11.5.1, pg 11.5-1 Assessment, moved the nuclear criticality safety requirements from the 3rd paragraph that are applicable to the NCS assessment, into paragraph 7 discussion about the NCS assessment.
AC 169116: Revised table in SAR Section 12, p 12.0-2 to correct the accident sequence, as CHEM RELEASE-WORKER EVAC is not an EE sequence 50a LBDCR-23-nnn GCP-077, IROFS50 Reevaluation. Deleted IROFS50a, b, c, d, e, h, i, and j following deletion of accident sequences OC1-1, OC1-2, OC2-1, and OC3-1 which were found to be Not Credible or having no consequences of concern. Added Accident VC1-6 which credits IROFSC23.
3.6 Chapter 3 Tables Safety Analysis Report Page-3.6-17 Rev 5050 IROFS Monitoring Support Equipment Other Equipment Equipment Attributes Operated Support Equipment Other Equipment Equipment Attributes None Topographical survey equipment Accurate and reliable topography reading None None None IROFS39a None None None None None None IROFS39b None None None None None None IROFS39c None None None None None None IROFS39d None None None None None None IROFS42 Weigh Scale System including local digital readout from weighing system at the cylinder stations
- (Notes 2 and 3)
None Accurate and reliable indication None None None IROFS46 None None None None None None IROFS50a None None None None Barriers Visible and substantial IROFS50b None None None None Barriers Visible and substantial IROFS50c None None None None Barriers Visible and substantial IROFS50d None None None None Barriers Visible IROFS50e None None None None None None IROFS50f None None None None Barriers Visible and substantial IROFS50g None None None None Barriers Visible IROFS50h None None None None Barriers Visible and substantial IROFS50i None None None None Barriers Visible
3.6 Chapter 3 Tables Safety Analysis Report Page-3.6-18 Rev 5050 IROFS Monitoring Support Equipment Other Equipment Equipment Attributes Operated Support Equipment Other Equipment Equipment Attributes IROFS50j None None None None Barriers None IROFS53a None Instrument for determining cylinder content assay Accurate and reliable indication Select isolation valves *(Note 2)
None Valve Position IROFS53b None Instrument for determining cylinder content assay Accurate and reliable indication Select isolation valves *(Note 2)
None Valve Position IROFS54a None Portable weigh scale with built-in digital readout, independent of IROFS54b Accurate and reliable indication None None None IROFS54b None Portable weigh scale with built-in digital readout, independent of IROFS54a Accurate and reliable indication None None None IROFS55a N/A Instrument(s) for determining uranium enrichment level (wt.% 235U),
independent of IROFS55b Accurate and reliable indication N/A Circulation pumps(for Slab Tanks)
Supports withdrawal of representative liquid sample IROFS55b N/A Instrument(s) for determining uranium enrichment level (wt.
% 235U), independent of IROFS55a Accurate and reliable indication N/A Circulation pumps (for Slab Tanks)
Supports withdrawal of representative sample IROFS56a None Instrument for determining gross 235U content Accurate and reliable indication None None None