Annual Radioactive Effluent Release Report
ML23132A204
Person / Time
Site: Quad Cities  
Issue date: 05/12/2023
From:
Constellation Energy Generation
To:
Office of Nuclear Reactor Regulation
Shared Package
ML23132A201 List:
References
SVP-23-022
Download: ML23132A204 (1)


Text

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 22 of 78 Quad Cities Generating Station Period of Record: January - March 2022 Stability Class - Extremely Unstable - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 0 0 0 0 0 0 NE 0 0 1 0 0 0 1 ENE 0 1 0 0 0 0 1 E 0 0 0 2 0 0 2 ESE 0 0 1 1 0 0 2 SE 1 0 0 0 0 0 1 SSE 0 0 0 0 0 0 0 S 1 2 3 0 0 0 6 SSW 0 6 12 0 0 0 18 SW 0 1 1 0 0 0 2 WSW 0 0 4 0 0 0 4 W 0 0 2 0 0 0 2 WNW 0 0 7 1 0 0 8 NW 0 0 0 5 0 0 5 NNW 0 0 0 0 0 0 0 Variable 0 0 0 0 0 0 0 Total 2 10 31 9 0 0 52 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 23 of 78 Quad Cities Generating Station Period of Record: January - March 2022 Stability Class - Moderately Unstable - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 0 1 0 0 0 1 NE 0 1 0 0 0 0 1 ENE 0 2 1 0 0 0 3 E 0 0 0 0 0 0 0 ESE 0 0 0 2 0 0 2 SE 0 0 1 0 0 0 1 SSE 0 0 0 0 0 0 0 S 0 1 0 0 0 0 1 SSW 0 0 3 0 0 0 3 SW 0 1 1 0 0 0 2 WSW 0 0 1 0 0 0 1 W 0 0 3 0 0 0 3 WNW 0 0 2 0 0 0 2 NW 0 0 1 1 0 0 2 NNW 0 0 2 0 0 0 2 Variable 0 0 0 0 0 0 0 Total 0 5 16 3 0 0 24 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 24 of 78 Quad Cities Generating Station Period of Record: January - March 2022 Stability Class - Slightly Unstable - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 3 0 0 0 3 NNE 0 0 2 0 0 0 2 NE 0 0 0 0 0 0 0 ENE 0 2 5 0 0 0 7 E 0 0 1 0 0 0 1 ESE 0 0 2 4 0 0 6 SE 1 2 0 0 0 0 3 SSE 0 3 6 0 0 0 9 S 0 2 1 0 0 0 3 SSW 0 7 3 0 0 0 10 SW 0 0 2 0 0 0 2 WSW 0 2 5 0 0 0 7 W 0 2 8 5 0 0 15 WNW 0 0 16 1 0 0 17 NW 0 1 12 0 0 0 13 NNW 0 1 6 0 0 0 7 Variable 0 0 0 0 0 0 0 Total 1 22 72 10 0 0 105 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 25 of 78 Quad Cities Generating Station Period of Record: January - March 2022 Stability Class - Neutral - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 28 66 15 0 0 109 NNE 0 10 37 7 0 0 54 NE 0 15 34 6 0 0 55 ENE 1 8 14 0 0 0 23 E 2 6 14 6 0 0 28 ESE 2 13 17 14 0 0 46 SE 4 13 4 0 0 0 21 SSE 1 48 13 0 0 0 62 S 5 25 2 0 0 0 32 SSW 5 20 16 2 0 0 43 SW 4 13 18 2 0 0 37 WSW 10 29 18 4 1 0 62 W 4 71 62 36 7 0 180 WNW 3 83 175 41 1 0 303 NW 2 54 61 3 0 0 120 NNW 0 22 52 6 0 0 80 Variable 0 0 0 0 0 0 0 Total 43 458 603 142 9 0 1255 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 26 of 78 Quad Cities Generating Station Period of Record: January - March 2022 Stability Class - Slightly Stable - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 7 10 5 0 0 0 22 NNE 5 6 3 0 0 0 14 NE 3 5 0 0 0 0 8 ENE 2 6 1 0 0 0 9 E 6 15 4 0 0 0 25 ESE 4 13 7 0 0 0 24 SE 11 21 7 0 0 0 39 SSE 3 29 14 0 0 0 46 S 3 18 22 1 0 0 44 SSW 6 25 12 1 0 0 44 SW 12 20 9 1 0 0 42 WSW 12 24 6 0 0 0 42 W 7 40 5 0 0 0 52 WNW 13 24 0 0 0 0 37 NW 2 18 0 0 0 0 20 NNW 6 8 0 0 0 0 14 Variable 0 0 0 0 0 0 0 Total 102 282 95 3 0 0 482 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 27 of 78 Quad Cities Generating Station Period of Record: January - March 2022 Stability Class - Moderately Stable - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 2 0 0 0 0 0 2 NNE 3 1 0 0 0 0 4 NE 3 1 0 0 0 0 4 ENE 4 1 0 0 0 0 5 E 6 1 0 0 0 0 7 ESE 7 17 0 0 0 0 24 SE 12 4 0 0 0 0 16 SSE 10 10 0 0 0 0 20 S 4 2 0 0 0 0 6 SSW 5 5 0 0 0 0 10 SW 5 0 0 0 0 0 5 WSW 3 0 0 0 0 0 3 W 5 5 0 0 0 0 10 WNW 5 1 0 0 0 0 6 NW 1 0 0 0 0 0 1 NNW 5 0 0 0 0 0 5 Variable 0 0 0 0 0 0 0 Total 80 48 0 0 0 0 128 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 28 of 78 Quad Cities Generating Station Period of Record: January - March 2022 Stability Class - Extremely Stable - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 3 0 0 0 0 0 3 NNE 2 0 0 0 0 0 2 NE 2 0 0 0 0 0 2 ENE 1 0 0 0 0 0 1 E 17 5 0 0 0 0 22 ESE 23 14 0 0 0 0 37 SE 13 1 0 0 0 0 14 SSE 8 1 0 0 0 0 9 S 5 0 0 0 0 0 5 SSW 4 0 0 0 0 0 4 SW 2 0 0 0 0 0 2 WSW 1 0 0 0 0 0 1 W 1 0 0 0 0 0 1 WNW 1 0 0 0 0 0 1 NW 1 0 0 0 0 0 1 NNW 3 2 0 0 0 0 5 Variable 0 0 0 0 0 0 0 Total 87 23 0 0 0 0 110 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 29 of 78 Quad Cities Generating Station Period of Record: January - March 2022 Stability Class - Extremely Unstable - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 0 0 0 0 0 0 NE 0 0 0 0 0 0 0 ENE 0 0 0 0 0 0 0 E 0 0 0 0 0 0 0 ESE 0 0 0 0 0 0 0 SE 0 0 0 0 0 0 0 SSE 0 0 0 0 0 0 0 S 0 0 0 0 0 0 0 SSW 0 0 3 2 4 0 9 SW 0 0 1 0 0 0 1 WSW 0 0 0 0 0 0 0 W 0 0 0 0 0 0 0 WNW 0 0 0 1 0 0 1 NW 0 0 0 1 2 1 4 NNW 0 0 0 0 0 0 0 Variable 0 0 0 0 0 0 0 Total 0 0 4 4 6 1 15 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 30 of 78 Quad Cities Generating Station Period of Record: January - March 2022 Stability Class - Moderately Unstable - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 0 0 0 0 0 0 NE 0 0 1 0 0 0 1 ENE 0 1 2 0 0 0 3 E 0 0 0 0 0 0 0 ESE 0 0 0 0 5 0 5 SE 0 0 0 0 2 0 2 SSE 0 0 0 1 0 0 1 S 0 0 0 1 1 0 2 SSW 0 0 3 3 2 0 8 SW 0 0 1 3 1 0 5 WSW 0 0 0 0 0 0 0 W 0 0 3 5 0 0 8 WNW 0 0 0 3 0 0 3 NW 0 0 2 3 2 2 9 NNW 0 0 1 0 0 0 1 Variable 0 0 0 0 0 0 0 Total 0 1 13 19 13 2 48 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 31 of 78 Quad Cities Generating Station Period of Record: January - March 2022 Stability Class - Slightly Unstable - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 3 2 0 0 5 NNE 0 0 1 1 0 0 2 NE 0 0 1 0 0 0 1 ENE 0 0 3 0 0 0 3 E 0 0 2 5 0 0 7 ESE 0 0 0 3 1 3 7 SE 0 0 0 0 0 0 0 SSE 0 1 1 2 2 0 6 S 0 0 0 3 0 0 3 SSW 0 2 3 0 2 0 7 SW 0 0 3 1 2 0 6 WSW 0 0 8 1 0 0 9 W 0 0 6 3 1 2 12 WNW 0 0 2 7 3 2 14 NW 0 0 11 13 7 0 31 NNW 0 1 7 4 0 0 12 Variable 0 0 0 0 0 0 0 Total 0 4 51 45 18 7 125 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 32 of 78 Quad Cities Generating Station Period of Record: January - March 2022 Stability Class - Neutral - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 8 21 50 28 0 107 NNE 1 7 9 23 7 0 47 NE 0 1 16 35 23 3 78 ENE 0 3 10 7 3 0 23 E 0 2 4 10 1 0 17 ESE 2 2 3 11 14 18 50 SE 0 1 8 3 13 1 26 SSE 0 4 19 11 12 2 48 S 1 4 19 18 10 0 52 SSW 0 15 8 22 12 2 59 SW 1 6 11 13 13 8 52 WSW 2 12 12 14 3 2 45 W 1 16 35 34 15 26 127 WNW 0 12 56 88 50 31 237 NW 0 14 60 127 41 10 252 NNW 1 10 13 47 15 0 86 Variable 0 0 0 0 0 0 0 Total 9 117 304 513 260 103 1306 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 33 of 78 Quad Cities Generating Station Period of Record: January - March 2022 Stability Class - Slightly Stable - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 4 8 4 0 0 16 NNE 0 1 9 9 0 0 19 NE 1 1 8 9 0 0 19 ENE 0 0 3 0 0 0 3 E 0 1 5 3 0 0 9 ESE 0 0 3 8 6 0 17 SE 0 2 3 13 5 0 23 SSE 1 3 6 15 13 1 39 S 0 2 10 18 21 3 54 SSW 1 3 8 19 10 18 59 SW 0 4 9 9 9 4 35 WSW 3 4 12 14 6 0 39 W 0 5 20 23 4 0 52 WNW 1 2 14 14 0 0 31 NW 0 5 7 4 0 0 16 NNW 1 4 8 6 0 0 19 Variable 0 0 0 0 0 0 0 Total 8 41 133 168 74 26 450 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 34 of 78 Quad Cities Generating Station Period of Record: January - March 2022 Stability Class - Moderately Stable - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 3 2 1 0 0 7 NNE 0 2 0 1 0 0 3 NE 1 0 0 0 0 0 1 ENE 1 6 0 0 0 0 7 E 1 3 4 3 0 0 11 ESE 0 1 0 1 0 0 2 SE 0 2 2 2 2 0 8 SSE 1 0 6 7 3 0 17 S 0 1 5 21 2 0 29 SSW 0 2 7 5 1 0 15 SW 0 3 4 2 1 0 10 WSW 0 0 1 0 0 0 1 W 1 4 6 1 0 0 12 WNW 1 2 6 2 0 0 11 NW 0 0 1 0 0 0 1 NNW 0 0 6 0 0 0 6 Variable 0 0 0 0 0 0 0 Total 7 29 50 46 9 0 141 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 35 of 78 Quad Cities Generating Station Period of Record: January - March 2022 Stability Class - Extremely Stable - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 2 0 0 0 0 0 2 NNE 1 0 0 0 0 0 1 NE 0 0 0 0 0 0 0 ENE 1 1 1 0 0 0 3 E 1 1 2 1 0 0 5 ESE 1 1 0 0 0 0 2 SE 1 1 4 5 0 0 11 SSE 0 1 3 13 0 0 17 S 2 0 1 4 0 0 7 SSW 0 0 3 8 0 0 11 SW 0 0 1 1 0 0 2 WSW 0 1 1 0 0 0 2 W 0 1 0 3 0 0 4 WNW 1 0 0 0 0 0 1 NW 1 2 0 0 0 0 3 NNW 0 0 0 0 0 0 0 Variable 0 0 0 0 0 0 0 Total 11 9 16 35 0 0 71 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 36 of 78 Quad Cities Generating Station Period of Record: April - June 2022 Stability Class - Extremely Unstable - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 1 0 0 0 1 NNE 0 0 0 0 0 0 0 NE 0 0 4 0 0 0 4 ENE 0 2 5 0 0 0 7 E 0 3 13 3 0 0 19 ESE 0 2 6 9 2 0 19 SE 0 1 7 6 0 0 14 SSE 0 10 21 3 0 0 34 S 0 11 11 1 0 0 23 SSW 0 34 12 0 0 0 46 SW 0 6 7 1 0 0 14 WSW 0 0 6 1 2 0 9 W 0 0 17 0 0 0 17 WNW 0 5 31 1 0 0 37 NW 0 4 14 0 0 0 18 NNW 0 3 6 0 0 0 9 Variable 0 0 0 0 0 0 0 Total 0 81 161 25 4 0 271 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 37 of 78 Quad Cities Generating Station Period of Record: April - June 2022 Stability Class - Moderately Unstable - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 1 0 0 0 1 NNE 0 0 0 0 0 0 0 NE 0 1 0 0 0 0 1 ENE 0 1 0 0 0 0 1 E 0 1 5 0 0 0 6 ESE 0 1 3 1 0 0 5 SE 0 1 0 2 0 0 3 SSE 0 1 0 0 0 0 1 S 0 4 1 0 0 0 5 SSW 0 4 1 0 0 0 5 SW 0 1 1 0 0 0 2 WSW 0 1 2 1 0 0 4 W 0 3 2 0 0 0 5 WNW 0 6 5 0 0 0 11 NW 0 5 1 0 0 0 6 NNW 0 2 1 0 0 0 3 Variable 0 0 0 0 0 0 0 Total 0 32 23 4 0 0 59 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 38 of 78 Quad Cities Generating Station Period of Record: April - June 2022 Stability Class - Slightly Unstable - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 1 2 0 0 0 3 NNE 0 1 0 0 0 0 1 NE 0 6 0 0 0 0 6 ENE 0 3 1 0 0 0 4 E 0 4 9 0 0 0 13 ESE 0 2 3 2 0 0 7 SE 0 3 3 2 0 0 8 SSE 0 7 2 0 0 0 9 S 0 5 2 0 0 0 7 SSW 0 6 3 0 0 0 9 SW 0 4 1 1 0 0 6 WSW 0 4 3 1 2 0 10 W 0 14 3 5 0 0 22 WNW 0 9 8 0 0 0 17 NW 0 12 2 0 0 0 14 NNW 0 4 3 0 0 0 7 Variable 0 0 0 0 0 0 0 Total 0 85 45 11 2 0 143 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 39 of 78 Quad Cities Generating Station Period of Record: April - June 2022 Stability Class - Neutral - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 19 15 2 0 0 36 NNE 1 22 7 9 0 0 39 NE 2 15 12 1 0 0 30 ENE 0 45 24 0 0 0 69 E 3 42 27 1 0 0 73 ESE 3 20 19 3 0 0 45 SE 4 17 27 1 0 0 49 SSE 8 15 15 1 0 0 39 S 9 12 5 1 0 0 27 SSW 7 33 7 1 0 0 48 SW 7 20 21 4 0 0 52 WSW 6 20 29 14 0 0 69 W 8 29 36 13 0 0 86 WNW 4 40 55 8 0 0 107 NW 2 41 22 1 0 0 66 NNW 2 26 16 0 0 0 44 Variable 0 0 0 0 0 0 0 Total 66 416 337 60 0 0 879 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 40 of 78 Quad Cities Generating Station Period of Record: April - June 2022 Stability Class - Slightly Stable - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 7 10 0 0 0 0 17 NNE 7 8 3 0 0 0 18 NE 5 9 1 0 0 0 15 ENE 7 19 4 0 0 0 30 E 9 27 5 2 0 0 43 ESE 18 23 11 2 0 0 54 SE 17 18 8 0 0 0 43 SSE 11 23 13 0 0 0 47 S 9 19 3 0 0 0 31 SSW 7 39 4 0 0 0 50 SW 9 24 3 0 0 0 36 WSW 7 25 3 0 0 0 35 W 9 27 3 0 0 0 39 WNW 3 22 0 0 0 0 25 NW 10 13 5 0 0 0 28 NNW 5 9 0 0 0 0 14 Variable 0 0 0 0 0 0 0 Total 140 315 66 4 0 0 525 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 41 of 78 Quad Cities Generating Station Period of Record: April - June 2022 Stability Class - Moderately Stable - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 2 3 0 0 0 0 5 NNE 6 0 0 0 0 0 6 NE 4 0 0 0 0 0 4 ENE 6 2 0 0 0 0 8 E 19 7 0 0 0 0 26 ESE 28 10 0 0 0 0 38 SE 15 3 0 0 0 0 18 SSE 9 9 0 0 0 0 18 S 12 0 0 0 0 0 12 SSW 6 0 0 0 0 0 6 SW 6 0 0 0 0 0 6 WSW 3 2 0 0 0 0 5 W 5 2 0 0 0 0 7 WNW 8 2 0 0 0 0 10 NW 4 3 0 0 0 0 7 NNW 4 5 0 0 0 0 9 Variable 0 0 0 0 0 0 0 Total 137 48 0 0 0 0 185 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 42 of 78 Quad Cities Generating Station Period of Record: April - June 2022 Stability Class - Extremely Stable - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 0 0 0 0 0 1 NNE 6 0 0 0 0 0 6 NE 3 0 0 0 0 0 3 ENE 8 1 0 0 0 0 9 E 12 8 0 0 0 0 20 ESE 23 3 0 0 0 0 26 SE 8 0 0 0 0 0 8 SSE 3 0 0 0 0 0 3 S 7 0 0 0 0 0 7 SSW 10 0 0 0 0 0 10 SW 3 0 1 0 0 0 4 WSW 3 0 0 0 0 0 3 W 3 0 0 0 0 0 3 WNW 5 1 0 0 0 0 6 NW 5 0 0 0 0 0 5 NNW 2 0 0 0 0 0 2 Variable 0 0 0 0 0 0 0 Total 102 13 1 0 0 0 116 Hours of calm in this stability class: 4 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 43 of 78 Quad Cities Generating Station Period of Record: April - June 2022 Stability Class - Extremely Unstable - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 0 0 0 0 0 0 NE 0 0 1 0 0 0 1 ENE 0 0 0 0 0 0 0 E 0 0 3 4 1 0 8 ESE 0 0 1 2 3 0 6 SE 0 0 0 0 2 10 12 SSE 0 0 1 2 6 11 20 S 0 0 2 6 13 1 22 SSW 0 0 13 12 3 0 28 SW 0 0 4 5 0 0 9 WSW 0 0 0 2 0 0 2 W 0 0 0 0 0 0 0 WNW 0 0 1 12 4 0 17 NW 0 0 3 8 0 0 11 NNW 0 0 1 0 0 0 1 Variable 0 0 0 0 0 0 0 Total 0 0 30 53 32 22 137 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 44 of 78 Quad Cities Generating Station Period of Record: April - June 2022 Stability Class - Moderately Unstable - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 1 0 0 1 NNE 0 0 0 0 0 0 0 NE 0 2 1 0 0 0 3 ENE 0 0 6 0 0 0 6 E 0 0 5 2 1 0 8 ESE 0 0 2 4 0 0 6 SE 0 0 3 3 1 5 12 SSE 0 0 4 0 0 4 8 S 0 2 3 2 3 3 13 SSW 0 0 7 5 3 1 16 SW 0 0 1 3 0 0 4 WSW 0 0 2 3 2 4 11 W 0 0 0 5 0 0 5 WNW 0 0 6 7 4 0 17 NW 0 1 12 9 2 0 24 NNW 0 0 7 5 0 0 12 Variable 0 0 0 0 0 0 0 Total 0 5 59 49 16 17 146 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 45 of 78 Quad Cities Generating Station Period of Record: April - June 2022 Stability Class - Slightly Unstable - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 1 2 1 0 0 4 NNE 0 1 0 0 0 0 1 NE 0 5 1 0 0 0 6 ENE 0 0 1 0 0 0 1 E 0 1 5 7 2 0 15 ESE 0 0 4 4 4 0 12 SE 0 3 3 1 3 5 15 SSE 0 3 0 2 0 1 6 S 0 4 4 3 4 0 15 SSW 0 4 3 4 2 0 13 SW 0 3 1 4 0 0 8 WSW 0 1 2 3 2 3 11 W 0 5 7 2 0 0 14 WNW 0 4 7 1 7 0 19 NW 0 3 15 2 1 0 21 NNW 0 0 7 2 0 0 9 Variable 0 0 0 0 0 0 0 Total 0 38 62 36 25 9 170 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 46 of 78 Quad Cities Generating Station Period of Record: April - June 2022 Stability Class - Neutral - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 5 11 12 1 0 29 NNE 0 5 12 11 5 2 35 NE 0 8 13 12 9 0 42 ENE 1 3 9 13 8 0 34 E 0 10 39 31 4 1 85 ESE 0 9 13 25 15 3 65 SE 1 8 7 17 15 8 56 SSE 3 5 7 4 17 16 52 S 3 11 7 10 12 5 48 SSW 3 10 8 20 9 3 53 SW 3 5 11 14 8 3 44 WSW 0 5 8 14 15 5 47 W 1 10 18 24 26 11 90 WNW 1 7 19 39 26 4 96 NW 2 17 34 54 8 3 118 NNW 0 6 22 22 1 0 51 Variable 0 0 0 0 0 0 0 Total 18 124 238 322 179 64 945 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 1 Hours of missing stability measurements in all stability classes: 2

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 47 of 78 Quad Cities Generating Station Period of Record: April - June 2022 Stability Class - Slightly Stable - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 1 4 3 0 0 8 NNE 0 6 10 5 0 0 21 NE 0 1 11 3 1 0 16 ENE 0 1 9 5 1 0 16 E 1 0 8 11 2 0 22 ESE 1 2 9 21 5 7 45 SE 0 1 9 13 11 1 35 SSE 1 8 11 22 6 4 52 S 1 2 18 30 20 8 79 SSW 0 2 12 35 12 1 62 SW 0 3 9 15 7 1 35 WSW 0 1 7 11 0 0 19 W 1 2 9 18 2 0 32 WNW 1 3 10 15 0 0 29 NW 0 1 15 16 2 0 34 NNW 0 4 8 10 1 0 23 Variable 0 0 0 0 0 0 0 Total 6 38 159 233 70 22 528 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 48 of 78 Quad Cities Generating Station Period of Record: April - June 2022 Stability Class - Moderately Stable - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 2 3 5 0 0 10 NNE 0 0 7 3 1 0 11 NE 0 1 4 5 0 0 10 ENE 1 0 0 0 0 0 1 E 0 3 0 5 0 0 8 ESE 1 1 3 10 3 1 19 SE 0 2 3 5 1 0 11 SSE 1 3 8 10 3 0 25 S 0 1 11 16 0 0 28 SSW 0 1 9 10 0 0 20 SW 0 1 2 3 0 0 6 WSW 0 0 3 1 0 0 4 W 0 0 3 3 0 0 6 WNW 1 2 2 4 0 0 9 NW 0 1 3 0 0 0 4 NNW 1 0 0 4 0 0 5 Variable 0 0 0 0 0 0 0 Total 5 18 61 84 8 1 177 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 49 of 78 Quad Cities Generating Station Period of Record: April - June 2022 Stability Class - Extremely Stable - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 1 0 0 0 1 NNE 0 1 3 0 0 0 4 NE 1 2 6 0 0 0 9 ENE 2 4 0 0 0 0 6 E 0 1 1 0 0 0 2 ESE 1 1 2 1 0 0 5 SE 0 0 1 3 2 0 6 SSE 0 0 3 5 1 0 9 S 0 1 2 2 0 0 5 SSW 0 3 6 2 0 0 11 SW 0 0 2 2 0 0 4 WSW 0 0 3 3 0 0 6 W 0 2 3 1 0 0 6 WNW 1 3 0 0 0 0 4 NW 0 0 0 0 0 0 0 NNW 0 0 0 0 0 0 0 Variable 0 0 0 0 0 0 0 Total 5 18 33 19 3 0 78 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 50 of 78 Quad Cities Generating Station Period of Record: July - September 2022 Stability Class - Extremely Unstable - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 1 5 0 0 0 6 NNE 0 1 0 0 0 0 1 NE 0 2 0 0 0 0 2 ENE 0 8 0 0 0 0 8 E 0 4 0 0 0 0 4 ESE 0 7 0 0 0 0 7 SE 0 13 0 0 0 0 13 SSE 0 37 1 0 0 0 38 S 0 20 2 0 0 0 22 SSW 0 23 0 0 0 0 23 SW 0 2 0 0 0 0 2 WSW 0 4 0 0 0 0 4 W 0 8 7 0 0 0 15 WNW 0 12 5 0 0 0 17 NW 0 4 8 0 0 0 12 NNW 0 0 3 0 0 0 3 Variable 0 0 0 0 0 0 0 Total 0 146 31 0 0 0 177 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 33

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 51 of 78 Quad Cities Generating Station Period of Record: July - September 2022 Stability Class - Moderately Unstable - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 5 1 0 0 0 6 NNE 0 3 0 0 0 0 3 NE 0 5 0 0 0 0 5 ENE 0 7 0 0 0 0 7 E 0 0 0 0 0 0 0 ESE 0 3 1 0 0 0 4 SE 0 5 1 0 0 0 6 SSE 0 6 0 0 0 0 6 S 0 1 0 0 0 0 1 SSW 0 4 0 0 0 0 4 SW 0 3 1 0 0 0 4 WSW 0 5 0 0 0 0 5 W 0 8 5 0 0 0 13 WNW 0 2 6 0 0 0 8 NW 0 2 3 0 0 0 5 NNW 0 0 1 0 0 0 1 Variable 0 0 0 0 0 0 0 Total 0 59 19 0 0 0 78 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 33

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 52 of 78 Quad Cities Generating Station Period of Record: July - September 2022 Stability Class - Slightly Unstable - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 9 1 0 0 0 10 NNE 0 7 2 0 0 0 9 NE 0 15 0 0 0 0 15 ENE 0 7 1 0 0 0 8 E 0 1 0 0 0 0 1 ESE 1 11 2 0 0 0 14 SE 0 10 0 0 0 0 10 SSE 0 14 1 0 0 0 15 S 0 4 0 0 0 0 4 SSW 0 10 0 0 0 0 10 SW 0 5 1 0 0 0 6 WSW 0 16 2 0 0 0 18 W 0 8 6 0 0 0 14 WNW 0 12 10 0 0 0 22 NW 0 10 2 0 0 0 12 NNW 0 6 3 0 0 0 9 Variable 0 0 0 0 0 0 0 Total 1 145 31 0 0 0 177 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 33

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 53 of 78 Quad Cities Generating Station Period of Record: July - September 2022 Stability Class - Neutral - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 6 31 24 2 0 0 63 NNE 5 45 5 1 0 0 56 NE 11 40 4 0 0 0 55 ENE 6 47 1 0 0 0 54 E 6 18 1 0 0 0 25 ESE 5 39 0 0 0 0 44 SE 12 33 0 0 0 0 45 SSE 7 35 0 0 0 0 42 S 4 16 1 0 0 0 21 SSW 8 17 1 0 0 0 26 SW 6 19 1 0 0 0 26 WSW 4 20 4 0 0 0 28 W 7 22 12 0 0 0 41 WNW 10 28 20 0 0 0 58 NW 5 29 10 0 0 0 44 NNW 2 24 10 0 0 0 36 Variable 0 0 0 0 0 0 0 Total 104 463 94 3 0 0 664 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 33

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 54 of 78 Quad Cities Generating Station Period of Record: July - September 2022 Stability Class - Slightly Stable - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 11 8 0 0 0 0 19 NNE 14 16 1 0 0 0 31 NE 15 9 0 0 0 0 24 ENE 13 6 0 0 0 0 19 E 12 13 0 0 0 0 25 ESE 20 11 0 0 0 0 31 SE 32 11 0 0 0 0 43 SSE 28 14 0 0 0 0 42 S 15 20 0 0 0 0 35 SSW 7 33 0 0 0 0 40 SW 10 28 1 0 0 0 39 WSW 7 18 2 0 0 0 27 W 18 62 4 0 0 0 84 WNW 26 33 7 0 0 0 66 NW 14 21 1 0 0 0 36 NNW 6 13 0 0 0 0 19 Variable 0 0 0 0 0 0 0 Total 248 316 16 0 0 0 580 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 33

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 55 of 78 Quad Cities Generating Station Period of Record: July - September 2022 Stability Class - Moderately Stable - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 8 3 0 0 0 0 11 NNE 12 0 0 0 0 0 12 NE 11 1 0 0 0 0 12 ENE 7 0 0 0 0 0 7 E 28 7 0 0 0 0 35 ESE 31 3 0 0 0 0 34 SE 29 2 0 0 0 0 31 SSE 12 0 0 0 0 0 12 S 5 0 0 0 0 0 5 SSW 12 0 0 0 0 0 12 SW 7 0 0 0 0 0 7 WSW 4 1 0 0 0 0 5 W 12 6 1 0 0 0 19 WNW 15 3 0 0 0 0 18 NW 5 2 0 0 0 0 7 NNW 5 0 0 0 0 0 5 Variable 0 0 0 0 0 0 0 Total 203 28 1 0 0 0 232 Hours of calm in this stability class: 9 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 33

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 56 of 78 Quad Cities Generating Station Period of Record: July - September 2022 Stability Class - Extremely Stable - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 5 0 0 0 0 0 5 NNE 14 0 0 0 0 0 14 NE 24 0 0 0 0 0 24 ENE 18 0 0 0 0 0 18 E 42 4 0 0 0 0 46 ESE 16 0 0 0 0 0 16 SE 3 1 0 0 0 0 4 SSE 2 0 0 0 0 0 2 S 4 0 0 0 0 0 4 SSW 2 0 0 0 0 0 2 SW 4 0 0 0 0 0 4 WSW 6 0 0 0 0 0 6 W 11 0 0 0 0 0 11 WNW 12 0 0 0 0 0 12 NW 9 0 0 0 0 0 9 NNW 7 0 0 0 0 0 7 Variable 0 0 0 0 0 0 0 Total 179 5 0 0 0 0 184 Hours of calm in this stability class: 74 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 33

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 57 of 78 Quad Cities Generating Station Period of Record: July - September 2022 Stability Class - Extremely Unstable - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 0 0 0 0 0 0 NE 0 0 0 0 0 0 0 ENE 0 0 0 0 0 0 0 E 0 0 0 0 0 0 0 ESE 0 0 0 0 0 0 0 SE 0 0 0 0 0 0 0 SSE 0 0 9 0 0 0 9 S 0 0 2 5 2 0 9 SSW 0 0 5 3 0 0 8 SW 0 0 0 0 0 0 0 WSW 0 0 0 0 0 0 0 W 0 0 0 1 0 0 1 WNW 0 0 1 0 0 0 1 NW 0 0 3 1 0 0 4 NNW 0 0 0 0 0 0 0 Variable 0 0 0 0 0 0 0 Total 0 0 20 10 2 0 32 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 33

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 58 of 78 Quad Cities Generating Station Period of Record: July - September 2022 Stability Class - Moderately Unstable - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 2 3 0 0 5 NNE 0 0 0 1 0 0 1 NE 0 1 3 0 0 0 4 ENE 0 3 11 0 0 0 14 E 0 1 0 0 0 0 1 ESE 0 0 4 0 0 0 4 SE 0 0 8 0 0 0 8 SSE 0 3 12 2 0 0 17 S 0 1 15 8 1 1 26 SSW 0 5 7 3 0 0 15 SW 0 1 1 0 0 0 2 WSW 0 0 0 0 0 0 0 W 0 2 2 5 0 0 9 WNW 0 0 4 4 0 0 8 NW 0 0 7 1 3 0 11 NNW 0 0 3 4 0 0 7 Variable 0 0 0 0 0 0 0 Total 0 17 79 31 4 1 132 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 33

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 59 of 78 Quad Cities Generating Station Period of Record: July - September 2022 Stability Class - Slightly Unstable - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 5 4 0 0 0 9 NNE 0 1 2 0 0 0 3 NE 0 10 10 0 0 0 20 ENE 0 5 10 0 0 0 15 E 0 1 1 0 0 0 2 ESE 0 2 2 0 0 0 4 SE 1 7 5 2 2 0 17 SSE 0 8 8 0 0 0 16 S 0 2 6 5 2 0 15 SSW 0 5 3 3 0 0 11 SW 0 3 3 0 1 0 7 WSW 0 2 5 3 0 0 10 W 0 8 8 3 0 0 19 WNW 0 8 2 8 4 0 22 NW 0 10 3 10 5 0 28 NNW 0 5 2 5 0 0 12 Variable 0 0 0 0 0 0 0 Total 1 82 74 39 14 0 210 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 33

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 60 of 78 Quad Cities Generating Station Period of Record: July - September 2022 Stability Class - Neutral - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 15 22 19 3 0 59 NNE 3 14 15 7 0 1 40 NE 0 28 36 6 3 0 73 ENE 2 18 35 2 0 0 57 E 0 13 11 3 0 0 27 ESE 1 9 10 5 1 0 26 SE 1 11 20 10 0 0 42 SSE 2 14 24 9 1 0 50 S 0 5 23 27 6 0 61 SSW 1 16 4 12 3 0 36 SW 3 4 10 11 1 0 29 WSW 0 4 18 4 3 0 29 W 7 7 6 14 2 0 36 WNW 4 8 15 25 7 0 59 NW 0 14 21 18 14 0 67 NNW 2 13 20 13 2 0 50 Variable 0 0 0 0 0 0 0 Total 26 193 290 185 46 1 741 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 33

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 61 of 78 Quad Cities Generating Station Period of Record: July - September 2022 Stability Class - Slightly Stable - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 3 11 7 0 0 21 NNE 2 8 19 5 0 0 34 NE 1 5 19 7 0 0 32 ENE 0 5 13 3 0 0 21 E 0 9 16 1 1 0 27 ESE 0 4 10 12 0 0 26 SE 1 6 11 16 1 0 35 SSE 0 3 13 14 1 0 31 S 1 4 20 47 2 0 74 SSW 0 2 18 38 11 1 70 SW 0 5 7 25 2 0 39 WSW 1 2 10 5 3 0 21 W 0 4 11 17 1 0 33 WNW 1 4 14 38 6 0 63 NW 0 2 17 18 7 0 44 NNW 1 4 8 8 0 0 21 Variable 0 0 0 0 0 0 0 Total 8 70 217 261 35 1 592 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 33

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 62 of 78 Quad Cities Generating Station Period of Record: July - September 2022 Stability Class - Moderately Stable - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 5 10 0 0 0 16 NNE 2 4 3 2 0 0 11 NE 0 5 5 1 0 0 11 ENE 2 4 10 0 0 0 16 E 0 4 8 1 0 0 13 ESE 0 2 11 10 0 0 23 SE 0 2 5 15 1 0 23 SSE 1 2 9 14 0 0 26 S 0 0 15 28 0 0 43 SSW 0 0 4 19 0 0 23 SW 0 1 2 3 1 0 7 WSW 0 3 4 5 0 0 12 W 2 4 3 6 0 0 15 WNW 0 1 7 9 1 0 18 NW 0 3 4 14 0 0 21 NNW 0 7 5 2 0 0 14 Variable 0 0 0 0 0 0 0 Total 8 47 105 129 3 0 292 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 33

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 63 of 78 Quad Cities Generating Station Period of Record: July - September 2022 Stability Class - Extremely Stable - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 3 1 1 0 0 0 5 NNE 1 8 0 0 0 0 9 NE 0 5 1 0 0 0 6 ENE 0 2 2 0 0 0 4 E 3 5 12 1 0 0 21 ESE 2 5 11 10 0 0 28 SE 2 4 3 4 0 0 13 SSE 2 8 7 6 0 0 23 S 2 7 5 4 0 0 18 SSW 1 2 4 0 0 0 7 SW 0 5 5 0 0 0 10 WSW 1 4 1 0 0 0 6 W 3 0 0 0 0 0 3 WNW 4 4 2 0 0 0 10 NW 1 4 2 0 0 0 7 NNW 1 3 2 0 0 0 6 Variable 0 0 0 0 0 0 0 Total 26 67 58 25 0 0 176 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 33

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 64 of 78 Quad Cities Generating Station Period of Record: October - December 2022 Stability Class - Extremely Unstable - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 2 1 0 0 0 3 NNE 0 1 1 0 0 0 2 NE 0 2 1 0 0 0 3 ENE 0 0 0 0 0 0 0 E 0 0 1 0 0 0 1 ESE 0 2 5 1 0 0 8 SE 0 5 4 0 0 0 9 SSE 0 4 10 0 0 0 14 S 0 7 6 0 0 0 13 SSW 0 17 12 0 0 0 29 SW 0 4 1 0 0 0 5 WSW 1 1 7 0 0 0 9 W 0 0 10 0 0 0 10 WNW 0 0 8 0 0 0 8 NW 0 0 2 0 0 0 2 NNW 0 0 0 0 0 0 0 Variable 0 0 0 0 0 0 0 Total 1 45 69 1 0 0 116 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 0

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 65 of 78 Quad Cities Generating Station Period of Record: October - December 2022 Stability Class - Moderately Unstable - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 1 0 0 0 1 NNE 0 2 1 0 0 0 3 NE 0 0 0 0 0 0 0 ENE 0 0 0 0 0 0 0 E 0 0 0 0 0 0 0 ESE 0 3 2 0 0 0 5 SE 0 0 0 0 0 0 0 SSE 0 2 2 0 0 0 4 S 0 1 3 0 0 0 4 SSW 0 3 0 0 0 0 3 SW 0 2 1 0 0 0 3 WSW 0 1 2 0 0 0 3 W 0 2 6 0 0 0 8 WNW 0 0 5 0 0 0 5 NW 0 1 1 1 0 0 3 NNW 0 0 1 0 0 0 1 Variable 0 0 0 0 0 0 0 Total 0 17 25 1 0 0 43 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 0

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 66 of 78 Quad Cities Generating Station Period of Record: October - December 2022 Stability Class - Slightly Unstable - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 1 0 0 0 1 NNE 0 2 0 0 0 0 2 NE 0 4 0 0 0 0 4 ENE 0 3 0 0 0 0 3 E 0 2 3 0 0 0 5 ESE 1 9 0 0 0 0 10 SE 0 2 0 0 0 0 2 SSE 0 3 2 0 0 0 5 S 0 3 1 0 0 0 4 SSW 0 6 1 0 0 0 7 SW 0 5 1 0 0 0 6 WSW 0 8 4 0 0 0 12 W 0 4 15 3 0 0 22 WNW 0 3 7 1 0 0 11 NW 0 2 1 0 0 0 3 NNW 0 1 0 0 0 0 1 Variable 0 0 0 0 0 0 0 Total 1 57 36 4 0 0 98 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 0

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 67 of 78 Quad Cities Generating Station Period of Record: October - December 2022 Stability Class - Neutral - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 6 7 0 0 0 14 NNE 4 11 2 0 0 0 17 NE 3 22 0 0 0 0 25 ENE 5 31 6 0 0 0 42 E 3 30 20 14 0 0 67 ESE 3 40 13 4 0 0 60 SE 4 8 9 0 0 0 21 SSE 4 15 18 0 0 0 37 S 5 13 7 0 0 0 25 SSW 3 21 13 3 0 0 40 SW 7 24 37 2 0 0 70 WSW 5 24 61 1 0 0 91 W 6 57 83 66 7 0 219 WNW 4 41 91 38 0 0 174 NW 3 26 11 0 0 0 40 NNW 1 25 14 2 0 0 42 Variable 0 0 0 0 0 0 0 Total 61 394 392 130 7 0 984 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 0

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 68 of 78 Quad Cities Generating Station Period of Record: October - December 2022 Stability Class - Slightly Stable - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 7 15 2 0 0 0 24 NNE 7 7 2 0 0 0 16 NE 4 6 0 0 0 0 10 ENE 4 18 0 0 0 0 22 E 10 16 5 0 0 0 31 ESE 9 25 4 0 0 0 38 SE 6 33 0 0 0 0 39 SSE 5 57 14 0 0 0 76 S 9 23 13 0 0 0 45 SSW 5 32 11 0 0 0 48 SW 17 38 5 0 0 0 60 WSW 13 29 0 0 0 0 42 W 4 42 3 0 0 0 49 WNW 5 14 3 1 0 0 23 NW 7 6 0 0 0 0 13 NNW 8 10 1 0 0 0 19 Variable 0 0 0 0 0 0 0 Total 120 371 63 1 0 0 555 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 0

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 69 of 78 Quad Cities Generating Station Period of Record: October - December 2022 Stability Class - Moderately Stable - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 8 0 0 0 0 0 8 NNE 4 2 0 0 0 0 6 NE 15 2 0 0 0 0 17 ENE 10 6 0 0 0 0 16 E 14 4 0 0 0 0 18 ESE 6 3 0 0 0 0 9 SE 8 11 0 0 0 0 19 SSE 5 27 0 0 0 0 32 S 8 3 0 0 0 0 11 SSW 4 3 0 0 0 0 7 SW 6 0 0 0 0 0 6 WSW 3 0 0 0 0 0 3 W 4 3 0 0 0 0 7 WNW 13 0 0 0 0 0 13 NW 4 3 0 0 0 0 7 NNW 4 1 0 0 0 0 5 Variable 0 0 0 0 0 0 0 Total 116 68 0 0 0 0 184 Hours of calm in this stability class: 1 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 0

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 70 of 78 Quad Cities Generating Station Period of Record: October - December 2022 Stability Class - Extremely Stable - 196Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 11 0 0 0 0 0 11 NNE 12 0 0 0 0 0 12 NE 7 0 0 0 0 0 7 ENE 14 0 0 0 0 0 14 E 37 6 0 0 0 0 43 ESE 38 7 0 0 0 0 45 SE 17 1 0 0 0 0 18 SSE 14 0 0 0 0 0 14 S 5 0 0 0 0 0 5 SSW 9 0 0 0 0 0 9 SW 9 0 0 0 0 0 9 WSW 8 0 0 0 0 0 8 W 8 1 0 0 0 0 9 WNW 4 0 0 0 0 0 4 NW 7 0 0 0 0 0 7 NNW 6 0 0 0 0 0 6 Variable 0 0 0 0 0 0 0 Total 206 15 0 0 0 0 221 Hours of calm in this stability class: 6 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 0

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 71 of 78 Quad Cities Generating Station Period of Record: October - December 2022 Stability Class - Extremely Unstable - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 0 0 0 0 0 0 NE 0 0 0 0 0 0 0 ENE 0 0 0 0 0 0 0 E 0 0 0 0 0 0 0 ESE 0 0 0 0 1 0 1 SE 0 0 0 0 0 0 0 SSE 0 0 1 4 4 1 10 S 0 0 0 2 3 1 6 SSW 0 0 3 4 3 0 10 SW 0 0 0 0 0 0 0 WSW 0 0 0 0 0 0 0 W 0 0 0 0 0 0 0 WNW 0 0 0 0 0 0 0 NW 0 0 0 0 0 0 0 NNW 0 0 0 0 0 0 0 Variable 0 0 0 0 0 0 0 Total 0 0 4 10 11 2 27 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 0

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 72 of 78 Quad Cities Generating Station Period of Record: October - December 2022 Stability Class - Moderately Unstable - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 0 3 0 0 0 3 NE 0 0 1 0 0 0 1 ENE 0 0 2 0 0 0 2 E 0 0 0 0 0 0 0 ESE 0 0 0 1 3 0 4 SE 0 0 0 2 0 0 2 SSE 0 0 2 4 1 0 7 S 0 0 1 2 1 0 4 SSW 0 0 6 7 3 0 16 SW 0 2 6 2 0 0 10 WSW 0 0 1 0 0 0 1 W 0 0 0 9 0 0 9 WNW 0 0 0 7 0 0 7 NW 0 0 0 3 5 0 8 NNW 0 0 0 0 1 0 1 Variable 0 0 0 0 0 0 0 Total 0 2 22 37 14 0 75 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 0

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 73 of 78 Quad Cities Generating Station Period of Record: October - December 2022 Stability Class - Slightly Unstable - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 1 0 1 0 2 NNE 0 1 5 0 0 0 6 NE 0 3 1 0 0 0 4 ENE 0 0 1 0 0 0 1 E 0 0 1 0 0 0 1 ESE 0 2 0 1 1 0 4 SE 0 7 1 0 0 0 8 SSE 0 1 0 1 1 1 4 S 0 0 1 4 2 0 7 SSW 0 2 4 4 2 0 12 SW 0 1 1 0 0 0 2 WSW 0 1 1 5 0 0 7 W 0 1 4 10 0 2 17 WNW 0 2 2 5 3 2 14 NW 0 0 3 7 2 0 12 NNW 0 0 0 0 1 0 1 Variable 0 0 0 0 0 0 0 Total 0 21 26 37 13 5 102 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 0

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 74 of 78 Quad Cities Generating Station Period of Record: October - December 2022 Stability Class - Neutral - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 9 8 5 5 0 28 NNE 0 3 6 2 0 0 11 NE 0 10 10 5 0 0 25 ENE 1 6 22 2 0 0 31 E 2 9 23 12 3 0 49 ESE 1 10 30 16 16 17 90 SE 0 12 15 17 1 0 45 SSE 0 6 2 4 13 7 32 S 0 4 5 16 19 1 45 SSW 0 8 5 17 9 5 44 SW 3 14 8 21 14 3 63 WSW 3 10 12 32 31 0 88 W 2 4 34 59 34 9 142 WNW 4 5 35 59 63 74 240 NW 0 2 29 39 29 1 100 NNW 2 6 16 21 4 0 49 Variable 0 0 0 0 0 0 0 Total 19 118 260 327 241 117 1082 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 0

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 75 of 78 Quad Cities Generating Station Period of Record: October - December 2022 Stability Class - Slightly Stable - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 6 5 10 0 0 21 NNE 0 3 4 7 0 0 14 NE 0 5 8 4 0 0 17 ENE 0 5 13 5 0 0 23 E 0 2 8 14 1 0 25 ESE 0 2 3 12 8 0 25 SE 0 3 5 10 4 0 22 SSE 0 1 7 31 21 6 66 S 0 3 4 19 43 7 76 SSW 1 5 12 17 30 7 72 SW 0 2 9 23 10 0 44 WSW 0 4 5 25 0 0 34 W 0 2 16 26 0 0 44 WNW 0 0 8 21 1 1 31 NW 0 1 8 18 1 0 28 NNW 0 1 6 1 0 0 8 Variable 0 0 0 0 0 0 0 Total 1 45 121 243 119 21 550 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 0

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 76 of 78 Quad Cities Generating Station Period of Record: October - December 2022 Stability Class - Moderately Stable - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 1 3 2 0 0 6 NNE 1 2 5 0 0 0 8 NE 0 1 5 2 0 0 8 ENE 0 3 4 3 0 0 10 E 0 8 14 3 0 0 25 ESE 0 5 9 9 0 0 23 SE 0 2 7 0 0 0 9 SSE 1 3 9 2 2 0 17 S 0 0 6 17 14 0 37 SSW 0 1 3 9 1 0 14 SW 0 0 7 10 2 0 19 WSW 0 1 0 4 0 0 5 W 0 0 4 4 0 0 8 WNW 0 1 3 1 0 0 5 NW 0 0 3 1 0 0 4 NNW 0 0 1 1 0 0 2 Variable 0 0 0 0 0 0 0 Total 2 28 83 68 19 0 200 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 0

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Joint Frequency Tables 77 of 78 Quad Cities Generating Station Period of Record: October - December 2022 Stability Class - Extremely Stable - 296Ft-33Ft Delta-T (F)

Winds Measured at 296 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 1 0 0 0 1 NNE 1 1 2 0 0 0 4 NE 1 0 3 0 0 0 4 ENE 2 1 0 0 0 0 3 E 0 3 2 0 0 0 5 ESE 1 2 5 1 0 0 9 SE 1 3 21 8 1 0 34 SSE 0 2 12 13 0 0 27 S 1 2 7 10 1 0 21 SSW 0 1 4 13 1 0 19 SW 1 3 5 8 2 0 19 WSW 0 2 9 1 0 0 12 W 1 0 7 0 0 0 8 WNW 0 2 2 1 0 0 5 NW 0 0 0 0 0 0 0 NNW 0 1 0 0 0 0 1 Variable 0 0 0 0 0 0 0 Total 9 23 80 55 5 0 172 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 0

Quad Cities Nuclear Power Station 2021 Annual Radioactive Effluent Release Report Page 79 of 79 Quad Cities Nuclear Power Station 2022 Annual Radioactive Effluent Release Report Solid Waste and Irradiated Fuel Shipments Page 1 of 1 A. Solid Waste shipped Offsite for Burial or Disposal (Not irradiated fuel)

1.

Types of Waste Types of Waste Total Quantity (m3)

Total Activity (Ci)

Period Est. Total Error %

a. Spent resins, filter sludges, evaporator bottoms, etc 1.41E+02 3.40E+02 2022 2.50E+01
b. Dry compressed waste, contaminated equip, etc 6.92E+02 1.54E+00 2022 2.50E+01
c. Irradiated components, control rods, etc N/A N/A N/A N/A
d. Other (describe) 2.42E+01 2.04E-03 2022 2.50E+01
2.

Estimate of major nuclides composition (by waste type)

Major Nuclide Composition

% / Ci

a. Fe-55 38.76% / 1.32E+02 Co-60 47.31% / 1.61E+02 Zn-65 1.16% / 3.96E+00 Ni-63 1.06% / 3.61E+00 Cs-137 9.73% / 3.31E+01 Mn-54 1.30% / 4.42E+00
b. Co-60 54.84% / 8.47E-01 Fe-55 31.07% / 4.80E-01 Zn-65 2.97% / 4.59E-02 Mn-54 6.17% / 9.54E-02 Ag-110m 0.89% / 1.37E-02 Cs-137 2.70% / 4.17E-02
c. N/A
d. Fe-55 35.11% / 7.16E-04 Co-60 50.63% / 1.03E-03 Zn-65 3.41% / 6.95E-05 Ag-110m 0.89% / 1.81E-05 Cs-137 1.53% / 3.13E-05 Mn-54 7.15% / 1.46E-04
3.

Solid Waste Disposition Number of Shipments Mode of Transportation Destination 14 Highway Processor 29 Highway Disposal B.

Irradiated Fuel Shipments (disposition)

Number of Shipments Mode of Transportation Destination N/A N/A N/A C.

Changes to the Process Control Program None.

D.

Major Changes to Radioactive Waste Treatment Systems: None.

Assess initiated safety related changes to the radioactive waste system (liquid, gaseous and solid) for the period in which the evaluation was reviewed, as applicable.